1 CCT 3 3 G74 V. A. Moore, Assistant Director for LWRs, Group 2, L POSITION STATEMENT PLANT NAME:
WPPSS Nuclear Project No.1 LICENSING STAGE:
CP DOCKET NUMBER:
50-460 & S0-513 RESPONSIBLE BRANCH:
LWR 2-3 REQUESTED COMPLETION DATE:
October 18, 1974 APPLICAdTS RESPONSE DATE HECESSARY FOR flEXT ACTIO!i PLANNED ON PROJECT:
As scheduled DESCRIPTION OF RESP 0tiSE:
Amendment to PSAR REVIEW STATUS:
Site Analysis Branch (llateorology) - Awaiting Information Attached is the staff's position on the subject plant.
In addition, the information required by the staff for completion of the site suitability (Lk!A) review has also been indicated.
All other meteorological information and data are complete.
This position was prepared by R. Kornasiewicz and E. Markee, Jr.,
Site Analysis Dranch, L.
Oths!s,'peny 5S 9.a:ltaa Harold R. Denton, Assistant 31 rector for Site Safety Directorate of Licensing
Enclosure:
As stated f.
cc:
w/o enclosure A. Giambusso 8605290228 741023 ADOCK05000gO W. licDonald PDR J. Panzarell.a t
cc:
w/ enclosure Distribution:
/
S. Manauer R. Kornastewicz L: Docket File V F. Schroeder E. tiarkee, Jr.
L:RDG SS Granch Chiefs R. Klecker L:SAB A. Kenneke
- 0. Eisenhut L:AD/SS A. Schwencer J. Carter T. Cox S. Varga gAllL:SAB L:SAAy L:SAJ Lf:AD/SS RKornasiewicz:ocEM W Wef'fiPGamlii H RDWiton
,,e,,,,,,,
1011111L 10Li.1174... 10123174
-10l!)A).l.74-7 I
Fates'AEC 318 (Rev.9 53) AICM 0240 W v. e. oovsanseent amenreme opricas es,4.eae.see l
I
)
r y
POSITION STATEMENT WASHINGTON PUBLIC POWER SUPPLY SYSTEM NUCLEAR PROJECT NO. 1 - UNITS 1 &4 DOCKET NUMBERS 50-460 & 50-513 METEOROLOGY 322.0l*
As stated in sub-section 2.3.3.1, (2.3.3) page 2.3-16(a) of the PSAR (Amend-ment 9, August 1974), onsite meteoro-logical data collection began at the new tower in February 1974.
In order to verify the conservativeness of the atmospheric dispersion (X/Q) values calculated by the staff using meteoro-logical data from the Hanford Meteoro-logical Station tower, provide joint frequency distributions of wind speed and direction by atmospheric stability (based on vertical temperature differ-ence) using preferably)nine or more (but not less than six months of data collected onsite.
- LWA Request for Additional Information also.
It is the staff's position that no (2.3.3) modification or deactivation of the present onsite meteorological measure-ments program be made after the issuance of the Construction Permit without prior discussion of the proposed modification or deactivation with the staff.
Conse-quently, provide a discussion of the proposed status of the onsite meteorolog-ical measurements program during the period subsequent to the issuance of the Construction Permit and prior to the issuance of the Operating License.
i b