" OWNERS GROUP y
i O_
r T~,".'.~..~.',"l...*.~'*"'
- 71,. s
!*.'' '.C.O,
c
.c,r s
e
=
s.,,,,,
me i g
m._-,.,_
.-s.
Working Together to Economically Provide Reliable and Safe Electrical Power May 20, 1986 Suite 220 7910 Woodmont Avenue Bethesda, Maryland 20814 Mr. D. M. Crutchfield (301)951 3344 Assistant Director for Technical Support U. S. Nuclear Regulatory Commission Washington, D. C.
20555
Subject:
UCS Report, " Safety Risks at Babcock & Wilcox Reactors: A Brief Summary"
Reference:
Letter from D. M. Crutchfield to H. B. Tucker dated April 4, 1986; same subject.
Dear Mr. Crutchfield:
The B&W Owners Group understands the points of view expressed in the UCS press release and letter to the Commission regarding the B&W reactors.
While the informa-tion appears to be worded in a way which dramatizes their concern and inflames public opinion, the technical subjects they address have, for some time, been receiving attention by the B&W Owners Group member utilities.
These efforts were expanded following the Davis-Besse and Rancho Seco transients in 1985.
Specific matters related to plan responsiveness, the auxiliary feedwater system, the integrated control system, and the non-nuclear instrumentation system have been, and are being, dealt with extensively in this expanded effort.
The B&W Owners Group Trip Reduction and Transient Response Improvement Program Plan includes the establish-ment of measurable performance goals regarding plant trip rates and transient response performance.
The B&W Owners Group is dedicated to achieving those goals.
We believe that the achievement of those goals will substantially reduce the UCS concerns.
The B&W Owners Group believes that the NRC's review of the program description will indicate that it does indeed address the concerns raised in the UCS information.
Very truly yours, Hal B. Tucker, Chairman B&W Owners Group Executive Committee HBT/JHT/?k cc: