To: Youngblood B
Office of Nuclear Reactor Regulation
References
NUDOCS 8605270134
Download: ML20198D942 (5)


Text

_

~Q Docket Nos.:

50-424 and 50-425-2 0 MM N MEMORANDUM FOR:

B. J. Youngblood, Director PWR Project Directorate #4 Division of PWR Licensing-A, NRR FROM:.

Melanie A. Miller, Project Manager PWR Project Directorate #4 Division of PWR Licensing-A, NRR

SUBJECT:

NOTICE OF FORTHCOMING MEETING ON V0GTLE ARBITRARY INTERMEDIATE PIPE BREAKS DATE & TIME:

June 4, 1986 8:30 a.m. - 12 noon LOCATION:

Phillips Building Room P-422 7920 Norfolk Avenue Bethesda, Maryland 20814 PURPOSE:

To discuss the location of welded attachments with respect to arbitrary intennediate pipe break locations and the applicant's analysis for considering attachments near locations of concerns.

PARTICIPANTS:

NRC SOUTHERN COMPANY SERVICES R-" Miller J. Bailey J.- Brammer

0. Batum G. Bagchi GEORGIA POWER COMPANY BECHTEL D. Hudson
5. Cereghino, et.al.

is \\

Melanie A. Miller, Project Manager PWR Project Directorate #4 Division of PWR Licensing-A, NRR cc: See next page h

PW

/hRf4 PWRf4/DPWR-A

{o8JYoungblood Jgl!C /85 br/mac v

05 05/ g /86 I

B605270134 860520 PDR ADOCK 05000424 x

A PDR

'4

,9 Mr. R. E. Conway Georgia Power Company Vogtle Electric Generating Plant cc:

Mr. L. T. Gucwa Resident Inspector Chief Nuclear Engineer Nuclear Regulatory Comission Georgia Power Company P. O. Box 572 P.O. Box 4545 Waynesboro, Georgia 30830 Atlanta, Georgia 30302 Mr. Ruble A. Thomas Deppish Kirkland, III, Counsel Vice President - Licensing Office of the Consumers' Utility Vogtle Project Council Georgia Power Company /

Suite 225 Southern Company Services, Inc.

32 Peachtree Street, N.W.

P.O. Box 2625 Atlanta, Georgia 30303 Binningham, Alabama 35202 James E. Joiner Mr. Donald 0. Foster Troutman, Sanders, Lockerman, Vice President & Project General Manager

& Ashmore Georgia Power Company Candler Building Post Office Box 299A, Route 2 127 Peachtree Street, N.E.

Waynesboro, Georgia 30830 Atlanta, Georgia 30303 Douglas C. Teper Mr. J. A. Bailey Georgians Against Nuclear Energy Project Licensing Manager 1253 Lenox Circle Southern Company Services, Inc.

Atlanta, Georgia 30306 P.O. Box 2625 Birmingham, Alabama 35202 Billie Pirner Garde Citizens Clinic Director Ernest L. Blake, Jr.

Government Accountability Project Bruce W. Churchill, Esq.

303 10th Street Shaw, Pittman, Potts and Trowbridge Augusta, Georgia 30901 1800 M Street, N.W.

Washington, D. C.

20036 Mr. G. Bockhold, Jr.

Vogtle Plant Manager Georgia Power Company Route 2, Box 299-A Waynesboro, Georgia 30830 Regional Administrator, Region II U.S. Nuclear Regulatory Comission 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323

4 MEETING NOTICE DISTRIBUTION "DodketFile

  • 0 1'%Y ge6 NRC Participants NRC PDR N. Miller L PDR J. Brammer NSIC G. Gagchi PRC System A. Herdt, Reg II PWR#4 Reading File J. Blake, Reg II M. Duncan E. Girard, Reg II Project Manager M. Miller ORAS H. Denton N. Olson H. Thompson E. Rossi, AD/PWR-A R. Ballard, EB C. Berlinger, RSB J. Milhoan, PSB l

F. Rosa, EICSB V. Benaroya, F0B OELD J. Partlow B. Grimes E. Jordan ACRS (10)

OPA Receptionist (Building where mtg is being held) bcc: Licensee / Applicant & Service List

ams

,f 1%,

UNITED STATES y

g NUCLEAR REGULATORY COMMISSION L

ij WASHINGTON, D. C. 20555

%....+ /

2 0 MAY 1986 Docket Nos.: 50-424 and 50-425 MEMORANDUM FOR:

B. J. Youngblood, Director PWR Project Directorate #4 Division of PWR Licensing-A, NRR FROM:

Melanie A. Miller, Project Manager PWR Project Directorate #4 Division of PWR Licensing-A, NRR

SUBJECT:

NOTICE OF FORTHCOMING MEETING ON V0GTLE ARBITRARY INTERMEDIATE PIPE BREAKS DATE & TIME:

June 4, 1986 8:30 a.m. - 12 noon LOCATION:

Phillips Building Room P-422 7920 Norfolk Avenue Bethesda, Maryland 20814 PURPOSE:

To discuss the location of welded attachments with respect to arbitrary intermediate pipe break locations and the applicant's analysis for considering attachments near locations of concerns.

PARTICIPANTS:

NRC SOUTHERN COMPANY SERVICES D iller J. Bailey J. Branner

0. Batum i

G. Bagchi GEORGIA POWER COMPANY BECHTEL D. Hudson

5. Cereghino, et.al.

0.

~

Melanie A. Miller, Project Manager l

PWR Project Directorate f4 l

Division of PWR Licensing-A, NRR l

t cc: See next~page

Mr. R. E. Conway

  • i Georgia Power Company Vogtle Electric Generating Plant cc:

Mr. L. T. Gucwa Resident Inspector Chief Nuclear Engineer Nuclear Regulatory Comission Georgia Power Company P. O. Box 572 P.O. Box 4545 Waynesboro, Georgia 30830 Atlanta, Georgia 30302 Mr. Ruble A. Thomas Deppish Kirkland, III, Counsel Vice President - Licensing Office of the Consumers' Utility Vogtle Project Council Georgia Power Company /

Suite 225 Southern Company Services, Inc.

32 Peachtree Street, N.W.

P.O. Box 2625 Atlanta, Georgia 30303 Birmingham, Alabama 35202 James E. Joiner Mr. Donald 0. Foster Troutman, Sanders, Lockerman, Vice President & Project General Manager

& Ashmore Georgia Power Company Candler Building Post Office Box 299A, Route 2 127 Peachtree Street, N.E.

Waynesboro, Georgia 30830 Atlanta, Georgia 30303 Douglas C. Teper Mr. J. A. Bailey Georgians Against Nuclear Energy Project Licensing Manager 1253 Lenox Circle Southern Company Services, Inc.

Atlanta, Georgia 30306 P.O. Box 2625 Birmingham, Alabama 35202 Billie Pirner Garde Citizens Clinic Director Ernest L. Blake, Jr.

Government Accountability Project Bruce W. Churchill, Esq.

303 10th Street Shaw, Pittman, Potts and Trowbridge Augusta, Georgia 30901 1800 M Street, N.W.

Washington, D. C.

20036 Mr. G. Bockhold, Jr.

Vogtle Plant Manager Georgia Power Company Route 2, Box 299-A Waynesboro, Georgia 30830 Regional Administrator, Region II U.S. Nuclear Regulatory Comission 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323