MAY 131992
.
'
Docket No. 50-333
Mr. Harry P. Salmon, h.
Resident Manager
New York Power Authority
James A. FitzPatrick Power Plant
Post Office Box 41
Lycoming, New York 13093
Subject: NRC Region I Inspection Report No. 50 333/92 03
Dear Mr. Salmon:
This refers to the results of the routine resident safety inspection conducted by Messrs. W. Cook
and R. Plasse from March 8,1992 to April 18,1992, at James A. FitzPatrick Nuclear Power
Plant, Scriba, New York. A summary of the inspection findings was presented to you and
members of your staff at the conclusion of the inspection.
This inspection was directed toward areas important to public health and safety. Areas examined
during the inspection are described in the NRC Region 1 inspection report, which is enclosed
with this letter. Within these areas, the inspection consisted of ob3ervation of activities,
interviews with personnel, and documem reviews.
Overall, performance during this inspection period was good. However, procedural adherence
problems and inattention by operations personnel resulted in the failure to maintain operator
awareness and control of the configuration of safety related valves, which led to overheating of
residual heat removal service water pump motor bearings and the subsequent failures to properly
investigate and identify the cause of the bearing high temperature alarms. This event was self-
identified and thoroughly evaluated by your staff, and the actual safety consequence of the event
was determined to be minimal with the fuel off loaded from the reactor. Therefore, these
procedural violations are not being cited, in accordance with the provisions of 10 CFR 2, Appendix C,Section V.G of the Enforcement Policy.
However, continued management
attention to the area of procedural adherence and operator vigilance is warranted.
l
l
OITICIAL RECORD COPY
a:lR-92 03.f712
9205210076 920513
,[ >/ a
DR
ADOCK 0500
3
j
__
- . . -
- - -
_
..
.
'
MAY 13102
,
New York Power Authority
2
Your cooperation with us is appreciated.
Sincerely,
Originni Signed By'.
Curtis J. Cowgill
Curtis J. Cowgill, Chief
Projects Branch No. I
Division of Reactor Projects
Enclosure: NRC Region i Inspection Report No. 50-333/92 03
cc w/ encl:
J. Brons, President
R. Beedic, Executive Vice President
J. Gray, Director, Nuclear Licensing - BWR
G. Goldstein, Assistant General Counsel
Supervisor, Town of Scriba
C. Donaldson, Esquire, Assistant Attorney General, New York Department of 1.aw
Director, Power Division, Department of Public Service, State af New York
Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NS,1C)
NRC Resident Inspector
.
State of New York, SLO Designts
K. Abraham, PAO-RI (2)
OFFICIAL RECORD COPY
a:lR-92-03.lT4
<
--- ,
,
-
g
--
,n
, - - -
- - - -
- - - - -
_
. _ . _
'
.
-t
,
MAY 131992
'
-
New York Power Authority
3
bec w/ encl:-
Region I Docket Room (with concurrences)
Management Assistant, DRMA (w/o encl)
'
C. Cowgill, DRP
R. Urban, DRP
D. Haverkamp, DRP
G. Meyer, DRP (Section 2.5)
-
G. Tracy, SRI - IP4
' P. Eapen, DRS (Section 2.5)
J. Caruso, DRS
W. Bateman, OEDO
<
R. Lobel, OEDO
R. Capra, NRR
B. McCabe, NRR
R. Jones, NRR (Section 2.5)
bec w/ Letter,LReport Cover Sheet and Executive Summary Only;
W. Hehl, DRP -
S. Shankman, DRP
!
W. Hodges, DRS
W. Lanning, DRS
,
L. Bettenhausen, DRS
^
C. Anderson, DRS
R. Cooper, DRSS
J. Durr, DRSS
~J.-Joyner DRSS
RI:DRP
. RI:DRP
RI:DRP h
. .h$
k/mjc
g kamp
CCowgill
5/W92
5/d92
5/D/92
L
,
L
l
OFFICIAL RECORD COPY
a:1R-92-03.1'I'Z
i
i
'
'
,..%.r
. + . - , , . , . . . _
.
. . _ _ . .
..~m.,
,
, - _ . _ , _ . -
- - , . . - . . . _ .
. . . . . .
.
-
.