Requests Response to Questions Re Application of leak-before-break Methodology to Justify Elimination of Accumulator Line Pipe Whip Restraints within 30 Days of Receipt of Ltr
ML20198D343
Person / Time
Site: Comanche Peak 
Issue date: 05/05/1992
From: Brian Holian
Office of Nuclear Reactor Regulation
To: William Cahill
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
References
TAC-M81986, NUDOCS 9205200145
Download: ML20198D343 (3)


Text

e prog 0,

a

  1. 'i s UNITED STATES E

..I [

I NUCLEAR REGULATORY COMMISSION

[

WASHINGTON. D.C. 20656 o.%,'

/

May 5, 1992 C

Docket No. 50-446 Mr. William J. Cahill, Jr.

Group Vice President TV Electric 5

400 North Olive Street, L.B. 81 f

Dallas, Texas 75201 y

Dear Mr. Cahill:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - COMANCHE PEAK UNIT 2, ACCUMULATOR LINE Af'ALYSIS (TAC N0. M81986)

[

The NRC staff has completed a preliminary review of your February 14, 1992 letter, requesting the applica' of leak-before-break methodology to justify elimination of acc;mulator line,,ipe whip restraints.

Based on the loads given in Table 4-1, the staff has verified the critical crack lengths presented in your submittal. However, the leak rates listed in Table 5-1 differ from the staff's calculated values by about 10 percent.

To verify the validity of Table 4-1, aad to resolve the dif ferences in the leak rate calculations, the staff requests the following additional information:

Safe Shutdown Earthquake (SSE) Load Modelling 1.

Describe in sufficient detail the SSE methodology used for generating Table 4-1.

Leak Rate Calculation 1.

Supply L/D and f values used in the frict:.nal pressure drop calculation n

for node point 2041, which leads to the resulting crack length for 10 gpm leakage reported in the first row of Table 5-1; also provide the corres-pondira values for pressure losses 6P, and APro pertinent to this node point.

ii!HC fill CBHER COPY 9205200145 920505 FN DR ADL'K 0500 6

m (n

Mr. William J. Cahill, Jr. May 5,1992 i

2.

Justify L/D - 40 as used in the submittal.

Studies ;ponsored by NRC (documented in NUREG/CR-3475 and CR-5128) indicate that flashing occurs at L/D - 12.

3.

Justify the number of 45* and 90" turns assumed for the flow path through the crack.

The reporting requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under Public Law 96-511.

We request your response to the qtiestions within 30 days of the receipt of this letter to enable the staff to complete its review in a timely manner.

Sincerely, Original Signed By Brian Holian, Senior Project Manager Project Directorate IV-2 Division of Reactot Projects Ill/IV/V Office of Nuclear Reactor Regulation cc: See next page DISTRIB_UTION:

Docket File NRC/PDR Local PDRs PDIV-2 Rdg File PDIV-2 Plt File BBoger MVirgilio EPeyton LYandell, RGN-IV EJordan ACRS(10)

BHolian JWiggins SSheng

OFFICr, PDIV-2/LA PDIV-2/PM J.PDIV-2/DM.A ED$N BHolian:W h5B1ackfdIN ms 4 @ /92 4/ s6 /92 4/ en /92

/ /

/ /

om

Mr. William J. Cahill, Jr. May 5,1992 cc:

Senior Resident inspector Jack R. Newman, Esq.

U.S. Nuclear Regulatory Comm ssion Newr.o & Holtzinger i

P. O. Box 1029 1615 L Street, N.W.

Granbury, Texas 76048 Suite 1000 Washington, D. L.

20036 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Chief, Texas Bureau of Radiation Control 611 Ryan Plaza Drive, Suite 1000 Texas Department of Healtn Arlington, Texas 76011 1100 West 49th Street Austin, Texas 78756 Mrs. Juanita Ellis, President

~

Citizens Association for Sound Energy Honorable Dale McPherson 1426 South Polk County Judge Dallas, Texas 75224 P. O. Box 851 Glen Rose, Texas 76043 Owen L. Thero, President Quality Technology Company Lakeview Mobile Home Park, Lot 35 4793 East Loop 820 South fort Worth, Texas 76119 Mr.- Roger D. Walker Manager, Nuclear Licensing Texas Utilities Electric Company 400 North Olive Street, L.B. 81 Dallas, Texas 75201 Texas Utilities Electric Company c/o Bethesda Licensing 3 Metro Center, Suite 610 Bethesda, Maryland 20814 William A. Burchette, Esq.

Counsel-for Tex-La Electric Cooperative of Texas Jorden, Schulte, & Burchette 1025 Thomas Jefferson Street, N.W.

Washington, D.C.

20007 GDS Associates, Inc.

Suite 720 1850 Parkway Place Marietta, Georgia 30067-8237

\\

+

j

- _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _