Text

p---- ----- ---- -- - -- -- -.m m m --- m m - =..- - m wm m -- -m ARM 9 k

NRC FORM sis U.S. NUCLEAR RE!ULATOMY COrlMISSloN I

=

CERTIFICATE OF CEMPLIANCE

'l io CFR 7' FOR RADIOACTIVE MATERIAL.S PACKAGES 14 CDITIFICATE NUwSER D REVISION NUMBER c PACKAGE 10ENiiFICATION NUMBER o PAGE NUMBER e TOTAL NUM8ER PAGES g,

9053 5

USA /9053/B(U) 1 2

g.

h-I 2 PREAM8LE I

a This certificate is issued to certify tnat the packaging and contents described in item 5 below, meets the applica0se safet y standards set forth in Title 10. Code q

of Federal Regulations. Part 71.

  • Packaging and Transportation of Radioactive MaterialJ l

I O This certificate does not reheve the consignor from comphance with any requirement of the regulations of the U S Department of Transportation or other k

appleCaDie regulatory agencies. Including the government of any Country through or into wnsch the package will be transported

.I Il' l

l' n

I!

3 THIS CERTIF8CATE IS ISSUED ON THE BASIS OF A SAFETY ANALY$l$ REPORT OF THE PACKAGE DESIGN OR APPLICATION h

a ISSUED TO 6same sad Aseem D TITLE AND IDENTIFICATION OF REPORT OR APPLICATION I

Technical Operations, Inc.

Technical Operations, Inc. application dated j

l 40 North Avenue June 16, 1980.

t lp g-Burlington, MA 01803 g

I

,E I

c OOCxET NuweER 71-9053 I

I I

a CONoT ONS Tnis ceniticaio is cond.tionai upon fuitining ine requirements of to crR Part 7i. as appocaoie and tne cond,iions so. citied o.4on li I

I (a) Packaging I

\\\\

l l

(1) Model No.:

683 lI I

I (2) Description l

ll l

I 1

A radiographic exposure device contained within a protective overpack.

il l

The overpack is an 18-gauge, itS27683 steel drun with a bolted and seal l

wire clamp closure ring. The drun is filled with molded rubberized ly g

hair to maintain a snug fit. Overall dimensions are 19.5" diameter x

!I I;

15" high. The radiographic exposure device consists of an ll-gauge

!I I

carbon steel shell, depleted uranium shielding, Zircalloy "S" tube, 1

I polyurethane filler material, source shipping plug and lock assembly.

N

[

Gross weight of the package is approximately 89 lbs.

j I!

Il g

(3) Drawings y

Il I

I:

The packaging is constructed in accordance with the following Technical E

@k li Operations, Inc. Drawing Nos.:

63390; A68313, Rev. A; and C68303, I

Rev. A.

1;l

n II il I

,1 1

l lt l

E l

i i

I I

I I

I I

I I

I I

I I

I I

8511120072 851105 PDR ADOCK 0710 3

l C

i g

I if I

lI

>l

\\

ll I

i

I


Kr.----

Tzrzerses_

m_mEwrawsswg CcNoiTI:Ns (continued) s Page 2 - Certificate No. 9053 - Revision No. 5 - Docket No. 71-9053 e

5.

(b) Contents (1) Type and form of naterial b)

Iridium 192 as sealed sources that meet the requirenents of special fom radioactive material.

p (2) Maxinun quantity of material oer package G;

120 curies 6.

Source assemblies for use in this packaging are limited to those assemblies as identified in Technical Operations, Inc. Drawing Nos. A68309, and C68310.

7.

Nameplate shall be fabricated of naterials capable of resisting the fire test of 10 CFR Part 71 and maintaining their legibility.

I:

8.

The packaging authorized by this certificate is hereby approved for use under the general provisions of 10 CFR $71.12, 9.

Expiration date: June 30, 1990.

Eij REFERENCE Technical Operations, Inc. application dated June 16, 1980.

FOR THE U.S. NUCLEAR REGULATORY COMl11SSION I,.

Transportation Certification Branch e44 TA Charles E. MacDonald, Chief Division of Fuel Cycle and I!

l'.aterial Safety, NfiSS NOV 0 51985 Dated:

/

'o, UNITED STATES E

  • 3 k, 'i NUCLEAR REGULATORY COMMISSION

(*

.E WASHINGTON, D. C. 20555 4,

,o Transportation Certification Branch Aoproval Record Model No. 683 Package Docket No. 71-9053 The certificate of compliance for the Model No. 683 package has been revised to correct the package identification number. By letter dated July 14,1930 the NRC staff notified the Department of Transportation that the package neets the IAEA requirements for Type B(U) packages.

This change was not incorporated into the package renewal issued on June 4, 1985.

h($f

~

Chaf e5'E.'MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NHSS Date:

NOV u 5 IINE I

!