December 10, 1998
i
.
'
Mr. G. A. Kuehn, Jr.
N
Progrtm Direct:r SNEC Facility
,
- '
GPU Nuclear, Inc.
' 2574 Interstate Drive
Harrisburg, Pennsylvania 17110
[
SUBJECT: NRC INSPECTION NO. 50-146/1998204
Dear Mr. Kuehn:
On November 6,1998, the NRC completed an inspection of the Large Component Removal
Project at the Saxton Nuclear Experimental Facility. ' The enclosed report represents the results
. of that inspection and subsequent discussions with you and your staff.
1
No violations of regulatory requirements or significant safety issues were identifimi during this
inspection. Accordingly, no response to this letter is required.
Your cooperation with us is appreciated.'
Sincerely,
ORIGINAL SIGNED'BY:
Seymour Hi Weiss, Director
. Non-Power Reactors and Decommissioning
Project Directorate .
,
'
Division of Reactor Program Management '
Office of Nuclear Reactor Regulation
Docket No. 50-146
License No. DPR-4
Enclosure: NRC Inspection Report No. 50-146/1998204
cc w/en':l:
D. P. Baldassari, President, SNEC
Dr. William Vemetson, TRTR
J. S. Wetmore, TMI Manager Nuclear Safety and Licensing
Saxton Reactor Facility Service List
Commonwealth of Pennsylvania
,.
,.
9812160258 981210
}-
ADOCK 05000146
G
.
DISTRIBUTION wiencl:
Doc / DESK
HARD COPY
PDoyle
TBurdick
6 151
JRoe
AAdams
MMendc 2.s
PUBLIC
TDragoun
g \\' Og
,
-
TMichaels '
SWeiss
EHylton
/
n O p'91 CBassett
SHolmes
DMatthews
PDND r/f
WEresian
i
"
O
Pisaac
-
'
p
g
/
TDragoun
n
fWss
O. 14 98
'
/2
/98
tv4c/98
OFFICIAL RECORD COPY
DOCUMENT NAME: G:\\SECY\\DRAGOUN\\SAXTON98.204
1?%13 f%@ V, f*b h
tw
_. _.
-
_ _ .
_
_
_
.
_
.
. _ .
_ _ . .
_
_
._
.
December 10, 1998
.
Pg g
Mr. G. A. Kurhn, Jr.
Program Director SNEC Facility
-
- GPU Nuclear, Inc.
2574 Interstate Drive
Harrisburg, Pennsylvania 17110
SUBJECT: NRC INSPECTION NO. 50-146/1998204
Dear Mr. Kuehn:
'
On November 6,1998, the NRC completed an inspection of the Large Component Removal
Project at the Saxton Nuclear Experimental Facility. The enclosed report represents the results
4
of that inspection and subsequent discussions with you and your staff.
No violations of regulatory requirements or significant safety issues were identified during this
inspection. Accordingly, no response to this letter is required.
Your cooperation with us is appreciated.
Sincerely,
ORIGINAL SIGNED BY:
Seymour H. Weiss, Director
Non-Power Reactors and Decommissioning
Project Directorate
Division of Reactor Program Management
Office of Nuclear Reartor Regulation
.
Docket No. 50-146
License No. DPR-4
Enclosure: NRC Inspection Report No. 50-146/1998204
cc w/ encl:
D. P. Baldassari, President, SNEC
Dr. William Vemetson, TRTR
J. S. Wetmore, TMI Manager Nuclear Safety and Licensing
Saxton Reactor Facility Service List
Commonwealth of Pennsylvania
'
DISTRIBUTION w/ encl:
Doc / DESK
HARD COPY
PDoyle
TBurdick
Docket File 50-151
JRoe
AAdams
MMendonca
PUBLIC
TDragoun
TMichaels
SWeiss
EHylton
SHolmes
CBassett
DMatthews
PDND r/f
WEresian
Pisaac
P
&dd
TDragoun
n
biss
(1 /498
/2> /98
tvW98
OFFICIAL RECORD COPY
DOCUMENT NAME: G:\\SECY\\DRAGOUN\\SAXTON98.204
.
.--
.
..
.
-
_
_
_
_
.
-
.
Pj o
/.9 us g
.
s
r
UNITED STATES
g
.
"
NUCLEAR REGULATORY COMMISSION
WASHINGTON, D.C. N1
%.....
December 10, 1998
,
l
Mr. G. A. Kuehn, Jr.
Program Director SNEC Facility
GPU Nuclear, Inc.
2574 Interstate Drive
Harrisburg, Pennsylvania 17110
'
SUBJECT: NRC INSPECTION NO. 50-146/1998204
Dear Mr. Kuehn:
On November 6,1998, the NRC completed an inspection of the Large Component Removal
'
Project at the Saxton Nuclear Experimental Facility. The enclosed report represents the results
of that inspection and subsequent discussions with you and your staff.
No violations of regulatory requirements or significant safety issues were identified during this
inspection Accordingly, no response to this letter is required.
Your cooperation with us is appreciated.
Sincerely,
r
J.A.No
!
/Sey
ur H. W iss, Director
Non-Power Reactors and Decommissioning
Project Directorate
Division of Reector Program Management
Office of Nuclear Reactor Regulation
Docket No. 50-146
License No. DPR-4
.
i
l
Enclosure: NRC inspection Report No. 50-146/1998204
cc wIencl:
l
D. P. Baldassari, President, SNEC
!
Dr. William Vemetson, TRTR
J. S. Wetmore, TMI Manager Nuclear Safety and Licensing
Saxton Reactor Facility Service List
Commonwealth of Pennsylvania
,
l
-
.
~
i
Saxton Nucitar
Dockst No. 50-146
'
Experimental Corporation
Page 1 of 2
I
cc:
Mr. Michael P. Murphy, Nuclear Engineer
Carbon Township Supervisors
Bureau of Radiation Protection
ATTN: Penny Brode, Secretary
Department of Environmental Protection
R. D. #1, Box 222-C
13th Floor, Rachel Carson State
Saxton, Pennsylvania 16678
Office Building
P. O. Box 8469
Hopewell Township Supervisors
Harrisburg, Pennsylvania 17105-8469
ATTN: Sally Giornesto, Secretary
RR 1 Box 95
Mr. Jim Tydeman
James Creek, Pennsylvania 16657-9512
l
1402 Wall Street
Saxton, Pennsylvania 16678
Mr. D. Bud McIntyre, Chairman
Broad Top Township Supervisors
Mr. James H. Elder, Chairman
Broad Top Municipal Building
Concerned Citizens for SNEC Safety
Defiance, Pennsylvania 16633
Wall Street Ext.
Saxton, Pennsylvania 16678
Mr. Don Weaver, Chairman
Liberty Township Supervisors
Mr. Ernest Fuller
R.D.#1
R.D.#1
Saxton, Pennsylvania 16678
Six Mile Run, Pennsylvania 16679
U.S. Army Corps of Engineers
Saxton Borough Council
Baltimore District
ATTN: Peggy Whited, Secretary
ATTN: S. Snarski/P. Juhle
9th and Spring Streets
P. O. Box 1715
Saxton, Pennsylvania 16678
Baltimore, Maryland 21203
Ms. Norma ickes, Chair
The Honorable Robert C. Jubelirer
Bedford County Commissioners
President Pro-Temp Senate of
County Court House
203 South Juliana Street
30th District
Bedford, Pennsylvania 15522
State Capitol
Harrisburg, Pennsylvania 17120
Mr. Larry Sather, Chairman
Huntingdon County Commissioners
Mr. William G. Heysek
County Court House
Licensing Department
Huntingdon, Pennsylvania 16652
TMI Nuclear Station
P. O. Box 480
Saxton Community Library
Middletown, Pennsylvania 17057
Front Street
Saxton, Pennsylvania 16678
Mr. Manuel Delgado
2799 Battlefield Road
Mr. Arthur Rone
Fishers Hill, Virginia 22626
,
Vice President Nuclear
!
Safety and Technical Services
Mr. Eric Blocher
GPU Nuclear Inc.
216 Logan Avenue
1 Upper Pond Road
Wyomissing, Pennsylvania 19610
Parsippany, New Jersey 07054
l
l
. -. . _ -
-
-
- . - .
. -
... .- . - . . . -
. . . . _ . _ _ . - . .
.
-.
-
!
' '
.
.
~ Saxton Nucie r
Dock:t No. 50-146
"
' Experimental Corporation
Page 2 of 2
cc:.
\\-
l
Ernest L. Blake, Jr., Esquire
Shaw, Pittman, Potts, and
l
Trowbridge
[
2300 N Street, NW .
' Washington, DC 20037
l
l Mr. David Sokolsky
l
,4241 Liberty Bell Ct.
Eureka, California 95503
.
)
Mr. Gene Baker
501 16th Street .
Saxton, Pennsylvania - 16678
Mr. Dick Spargo .
1004 Main Street
4
a
_ Saxton, Pennsylvania 16678
Mr. Tom Stmad
TLG Services
148 New Milford Road East
Bridgewater, Connecticut 06752
1
Mr. Gareth McGrath
Altoona Mirror
301 Cayuga Avenue
Altoona, Pennsylvania 16603
Charles Barker
RD 1 Box 143
y
James Creek, Pennsylvania 16657
'
James Fockler, Chairman
Saxton Citizens Task Force
1505 Liberty Street
Saxton, Pennsylvania 16678
Dr. Rodger W. Granlund
.. Saxton Independent inspector
Radiation Science and Engineering Center
The Pennsylvania State University
.-
Breazeale Nuclear Reactor
University Park, Pennsylvania 16802-2301
l
,
!.
,
'
.
L-
l
4
,
,
,-
- , _
-
. - - , ,
,
..
~
.
.
l%
F .,
EXECUTIVE SUMMARY
The Large Component Removal Project (LCRP) was well managed by the licensee staff. The
,
'
!
engineering, labor, safety, and heavy load handling services performed by the subcontractors
1-
were satisfactory. No safety concems or violations of regulatory requirements were identified.