Text
.
bk Y!
t
.s APR I 1985 MEMORANDUM FOR:
Thomas M. Novak, Assistant Director for Licensing Division of Licensing FROM:
Robert J. Bosnak, Acting Assistant Director for Components and Structures Engineering Division of Engineering
SUBJECT:
INPUT FOR WNP-2 SAFETY EVALUATION REPORT SUPPLEMENT, SECTION 3.11, ENVIRONMENTAL QUALIFICATION OF ELECTRICAL EQUIPMENT IMPORTANT TO SAFETY AND SAFETY-RELATED MECHANICAL EQUIPMENT Plant Name:
WNP.2 Docket No.:
50-397 Licensing Stage: OR Responsible Branch & Project Manager:
LB #2, R. Auluck Review Status:
Complete The enclosed SER Supplement was prepared by the Equipment Qualification Branch, Division of Engineering.
It addresses the request made by the licensee to revise License Condition (28) to incorporate a November 30,'1985 deadline for completion of environnental qualification instead of the presently imposed March 31, 1985 deadline.
Robert J. Bosnak, Acting Assistant Director for Components and Structures Engineering Division of Engineering
Enclosure:
As stated cc:
J. P. Knight A. Schwencer V. Noonan R. Auluck R. LaGrange EQ Section IFC
- DE:EQB
- DE:E08
..... :....../g... :....... p.... ::DE:CSE,:............:............:............:.......--..
.'AME : AMasciantonio RLaGrange
- RJBosnak
....:............:............:/............:............:............:........--..:...........
- 3/19/85
,2 7 / /85 7
- N
' ATE :3//f/85 ljj y jjjjj j
OFFICIAL RECORD COPY u
,L r
j PD(
~
EQUIPMENT QUALIFICATION BRANCH INPUT FOR SAFETY EVALUATION REPORT SUPPLEMENT e
WNP2 DOCKET NUMBER 50-397 3.11 Environmental Oualification of Electric Eouipment Important to Safety and Safety Related Mechanical Equipment INTRODUCTION 10 CFR 50.49, " Environmental Qualification of Electric Equipment Important to Safety for Nuclear Power Plants," establishes deadlines for completion of the environmental qualification of electrical equipment.
License Condition (28) to Operating License NPF-21 of WPPSS Nuclear Plant No.
2 requires that prior to March 31, 1985, the licensee shall environmentally qualify all electrical equipment according to the provisions of 10 CFR 50.49.
Plants are allowed to operate prior to the deadline for qualification specified in 10 CFR 50.49, or any extension to that deadline granted by the staff or the Commission, with equipment whose qualification has not been completed if it can be shown that such operation will not present undue ' risk to the public health and safety pending complete qualification. Analyses, called justifications for interim operation (JI0s), are required to be performed by the licensee to demonstrate the plant can be operated in a safe manner with the equipment not yet fully qualified.
The licensee has provided JI0s addressing the equipment for which an extension to the qualification deadline has been requested.
)
EVALUATION l
By letters G02-85-021, G02-85-048 and G02-85-122 from G. C. Sorensen (WPPSS) to A. Schwencer (NRC), dated January 17, January 30 and March 8, 1985, respectively, the licensee requests that License Condition (28) be revised to extend the deadline for completion of environmental qualification to l
November 30, 1985 for the following equipment items:
MS-LITS-26A Level Transmitter
-26B
-26C
-26D PSR-V-X77A/1 Solenoid Valve j
-X77A/3 l
RRA-RMS-FN/1 Remote Manual Switch
-FN/2
-FN/3 l
l
REA-E/P-1A Electro / Pneumatic
-1B Converters LPCS-PIS-1 Pressure Switch CIA-V-39A Valve RCIC-MO-V/63 Motor Operator RWCU-MO-V/1 Motor Operator 02-LPRM-CONN-XXXXX Connectors for LPPM 02-LPRM-DET-XXXXX PWR Rge Det Assemblies We have reviewed each of the JI0s provided by the licensee and find them acceptable.
The JI0s are based on the criteria contained in 10 CFR 50.49(i).
The licensee has stated that all applicable Justifications for Interim Operation have been reviewed and had concluded that they will remain valid and effective until November 30, 1985. The staff has reviewed the information provided and concurs with the results presented.
CONCLUSION Based on the above evaluation, we conclude that continued operation of WNP-2 with the environmental qualification of the equipment identified above not fully established, will not present undue risk to the public health and safety.
8