ML20197H401

From kanterella
Jump to navigation Jump to search
Discusses Acceptance for Referencing TR CENPD-137(P),Suppl 2, Calculative Methods for C-E Small Break LOCA Evaluation Model
ML20197H401
Person / Time
Issue date: 12/18/1997
From: Essig T
NRC (Affiliation Not Assigned)
To: Rickard I
ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
References
TAC-M89400, NUDOCS 9712310269
Download: ML20197H401 (2)


Text

@)f. kNWML

);

r.

3 p

mwag UNITED STATES

,l. ' -

j

}

NUCLEAR REGULATORY COMySSI,0N r.g.; g-dC8 - "

WASHiNOToN, D.C. 3025m01 3 ' -

't*..... 8 Im OrtIB 1]lO ?6 I USLIC DOCUllDii h00ll Mr. Ian C. Rickard, Ofrector Operations Licensing ABB Combustion Engineering Nuclear Systems 2000 Day Hill Road P.O. Box 500 Windsor, Connecticut 06095-0500

SUBJECT:

ACCEPTANCE FOR REFERENCING Of THE TOPICAL REPORT CENPD-137(P).

SUPPLEMENT 2. " CALCULATIVE METHODS FOR Ti1E C-E SMALL BREAK LOCA EVALVATION MODEL" (TAC NO._M89400)

Dear Mr. Rickard:

i We have concluded our review of the subject topical report of May 1996 with additions, modifications, and clarifications tirough Anril 3, 1997, submitted by the ABB Combustion Engineering Nuclear Systems (ABB-CE) company.

The report is acceptable for referencing to the extent specified and under the limitations delineated in the report and in the associeted NRC evaluation, which is enclosed.

The evaluation defines the basis of acceptance of the report.

We do not intend to repeat our review of the matters described in the report and found acceptable when the report appears as a reference in license applications, except to assure that the material presented is applicable to the specific plant involved.

Our acceptance applies only to matters described in the report.

The staff reviewed CENPD-137(P)

Supplement 2, and concluded that the small-break loss-of-coolant aceident (SBLOCA) evaluation model described therein complies with the requirements of 10 CFR Part 50.46 and 10 CfR 50, Appendix K, and that such applications of the SBLOCA evaluation model as described in CENPD-137(P), Supplement 2, and the enclosed safety evaluation report are, therefore, acceptable.

In accordance with procedures established in NUREG-0390 " Topical Report Review Status," we request that ABB Combustion Engineering publish accepted versions of this topical report, proprietary and non-proprietary, within 3 months of receipt of this letter.

The accepted versions shall incorporate

//

this letter and the enclosed evaluation between the title page and the

/

abstract.

/

)[ 2 9712310269 971218 PDR TOPRP EMVC-E

\\%QWYY e

~

J

Mr. 1. C. Rickard It must be well indexed such that information is readil;t located.

Also, it must contain in appendices historical review informatior, such as questions and accepted responses, and original report pages that were replaced. The accepted versions shall include an "A" (designi. ting accepted) following the re> ort identification symbol.

The staff will review this report when it is su)mitted.

If our criteria or regulations char.ge so that our conclusions as to the acceptability of the report are invalidated, ABB-CE and/or the applicants referencing the topical report will be expected to revise.ind resubmit their respectivo documentation, or submit justification for the tentinued applicability of the topical report without revision of their respective documentation.

Sincerely, m

Yt 3 x,)' y Qnc ~

Th.:as H. E sia, Acting BrinciChief Generic issues and EnvironmenLil Projects Branch Division of Reactor Program Management Office of Nuclear 9eactor Regulation

Enclosure:

CENPD-137(P), Supplement 2 Evaluation m

m

,,-