ML20197G374

From kanterella
Jump to navigation Jump to search
Submits Daily Highlight.As of 840419,reactor Pressure Is 1,000 Lbs W/Reactor Coolant Temp at 540 F & Power Level Approx 5%.Power Ascension Program Resumed
ML20197G374
Person / Time
Site: Columbia 
Issue date: 04/20/1984
From: Rajender Auluck
Office of Nuclear Reactor Regulation
To: Case E, Harold Denton, Edison G
Office of Nuclear Reactor Regulation
References
CON-WNP-0750, CON-WNP-750 NUDOCS 8405020333
Download: ML20197G374 (1)


Text

\\

n APR 2 01984 j

Docket No. 50-397 MEMORALDUti FOR:

H. R. Denton, NRR E. G. Case, ?!RR G. Edison, NRR D. G. Eisenhut, DL R. A. Purple, DL H. Thompson, DHFS R. H. Vollmer, DE R. J. Mattson, DSI T. P. Speis, DST J. Taylor, I&E i

G. Holahan, ORAB T. M. Novck, DL G. Lainas, DL F. fiiraglia, DL THRU:

A. Schwencer Chief Licensing Branch No. 2 Division of Licensing FROM:

R. Auluck, Project Manager Licensing Branch No. 2, DL

SUBJECT:

DAILY HIGHLIGHT - WNP-2 PLANT STATUS As of 2:00 PM (EST) April 19, 1984, the reactor pressure is at 1000 pounds with the reactor coolant temperatures at 540 F.

The drywell average tenperature is 117 F (well under the technical specification limit of 135 F).

However two areas have temperatures of 158'F and thus, the plant is in a 30-day action statement with regard to these local drywell high terperatures.

The power level is approximately 5%.

The pcwer ascension progran has been resumed which will take the plant to :pproximately 15% power next week.

]

p-l R. Auluck, Project Manager Licensing Branch No. 2 Division of Licensing LB#2 Rdg.

~

EHylton O!$00 bc 7

c W. Paton, OELD l

SBlack

/PM DL:L<3#2/BC ck:kw ASchwencer 4

/84 4/ /84

\\.-

.