. - - _ - _ _ -

Docket No. 50-397 MEMORANDUM FOR:

Thomas M. Novak, Assistant Director for Licensing Division of Licensing FROM:

William V. Johnston, Assistant Director Materials, Chemical & Environmental Technology Division of Engineering

SUBJECT:

SAFETY EVALUATION OF THE WNP-2 SACRIFICIAL SHIELD WALL STRUCTURAL DEFECTS AND THEIR REPAIRS Plant Name:

Washington Public Power Supply System, WNP-2 Supplier:

General Electric / Brown & Root, Bechtel Docket No:

50-397 Reviewer:

D. E. Smith Responsible Branch & Project Manager:

LB #2, R. Auluck Description of Task:

Safety Evaluation of the Structural Integrity of the Sacrificial Shield Wall of WNP-2 This memorandum is in response to your verbal request to review " Nuclear Project 2 Engineering Evaluation of the WNP-2 Sacrificial Shield Wall Supplement No. 3 - Final Report," forwarded by WPPSS letter G02-83-071, January 26, 1983.

The Materials Application Section, Materials Engineering Branch, Division of Engineering has completed its review of this report and its supplements.

We recommend acceptance of the report.

The material properties, con-struction, fabrication, nondestructive examinations performed, and fracture mechanics considerations provide reasonable assurance of the structural integrity of the sacrificial shield wall.

We judge that the sacrificial shield wall does not present an undue risk to the public health and safety.

Our safety evaluation is attached.

William V. Johnston, Assistant Director Materials, Chemical & Environmental Technology Division of Engineering cc:

See Page 2

Contact:

D. Smith

- X-2 3 ~ ~~~

060291 840127 e ADOCK 05000397 i

~

JAN 2 7 1984 Thomas M. Novak cc:

R. Vollmer D. Eisenhut T. Novak J. P. Knight E. Sullivan W. V. Johnston S. Pawlicki R. Bosnak G. Lear R. Auluck B. D. Liaw W. Hazelton R. Klecker C. Y. Cheng C. D. Sellers DISTRIBUTION:

MTEB WNP-2 l

f DE:MTEB DE;F EB Db: IB DE:AD:MCET D. Smith: jar W.-Ha biton D Liaw W. V. Johnston B[/

12/ /5, /83 12/ j cj

/83

/83-12/

/83

7. //

l vi 1, :-r

.