O OfSTRIBUTION

~

o Docket File EHEB Reading RBallard GlaRoche JDL 1 1 7983 Docket No.: 50-508 MEMORANDUM FOR: George Knighton, Chief Licensing Branch No. 3 Division of Licensing FROM:

Ronald L. Ballard, Chief Environmental and Hydrologic Engineering Branch Division of Engineering SUBJECTl WNP-3 ENVIRONMENTAL REVIEW: REQUEST FOR ADDITIONAL INFORMATION Attached are requests for additional information arising from our current review of the applicant's Environmental Report-OL Stage (Attachment 1).

Applicant's responses to these.infomational needs are required for continuation of our OL Environmental Review.

This review was conducted by G. LaRoche of the Environmental Engineering Section.

OrtBinal signed oy rtonawa L. Balised Ronald L. Ballard, Chief Environmental and Hydrologic Engineering Branch Division of Engineering

Attachment:

As stated cc:

A. Vietti l

0 '-

8307ggg2ggg%g i,

.a

_..=~'"

  • D E : E Eb y....,I..

[

l ~"~'*:.RBal as.

i

""" 7/tl/83 i

to cav ne m: wcm:m CFFICIAL RECCRD CCPY

-3 REQUEST FOR ADDIT 0NAL INFORMATION WNP-3 OL STAGE ENVIRONMENTAL REVIEW Terrestrial Thisquestionwasaskedprehiously. The answer is inadequate. The P'

E290.06 isopleths provided in figure 5.1-4 should be superimposed on an aerial photograph or map of the site in order to be able to evaluate which land use will be impacted by the drift.

In addition figure 5.1-4 does not have either an isopleth for 2 lb/ acre-yr or any indication of where the 20 lb/ acre-yr area is located or where the 45 lb/ acre-yr will occur. Please provide.

E290.08 ER-OLfigure2.2-1shouldhaheanoutlineofthesite. p 2.1-1, ER-OL stages that land owned by the Supply System in the site proper totals about 1,120 acres. On p 2.2-1 ER-OL it states the WNP-3 site is approximately 800 acres. The FES-CP p 2-1 states that the site encompasses approximately 2,270 acres. To clear up the confusion provide a recent period photograph.or map of the site on which is supperimposed the current site boundary, the exclusion zone and the site boundary at the CP stage. Provide the number of hectares (acres) contained within these 3 boundaries.

E290.09 ER-OL figure 2.2-2 should have the roads and site boundary indicated.

Also the stippled area should be identified.

E290.10 If any portion of the site could have been classified as prime agri-cultural land (Note: this includes prime forest land) before con-struction was beguri provide an aerial photograph or map indicating those areas and the number of hectares (acres) of prime agricultural land that will be occupied by permanent facilities and the total prime