ML20197D153
ML20197D153 | |
Person / Time | |
---|---|
Issue date: | 11/13/1978 |
From: | Parr O Office of Nuclear Reactor Regulation |
To: | Sherwood G GENERAL ELECTRIC CO. |
Shared Package | |
ML20197D157 | List: |
References | |
NUDOCS 7811210402 | |
Download: ML20197D153 (1) | |
Text
A[ 0, [3 g
[
d' ' +
d UNITE D ST ATES d4 NUCLEAR REGULATORY COMMisslON
$ ..k }h WASHING TON, D. C. 20555 Q*$9l/ ****
NOV 13 E8 '-
Central Files - Topical Reports Dr. G. G. Sherwood Manager - Safety and Licensing General Electric Company 175 Curtner Avenue San Jose, California 95114
Dear Dr. Sherwood:
\
SUBJECT:
REVIEW Of GENERAL ELECTRIC TOPICAL REPORT NED0-21778, " TRANSIENT 3 PRESSURE RISES AFFECTING FRACTURE TOUGHNESS REQUIREMENTS FOR BOILING WATER REACTORS" We have completed our review of the subject topical report and have concluded that the report provides an acceptable basis for an amendment to Appendix G of 10 CFR 50. Our proposed revision to Paragraph IV.A.2.c of Appendix G is currently being reviewed within the NRC prior to publication in the Federal Register for a public comment period. Our evaluation of NED0-21778 includes our proposed change to Appendix G and is attached.
In accordance with established procedure, we request that General Electric issue a revised version of the subject topical report which includes any supplementary information provided for our review of the report, this acceptance letter, and the enclosed staff evaluation.
Sincerely, flanD.parr, I.f- Chief Light Water Reactors Branch No. 3 Division of Project Management
Enclosure:
Topical Report Evaluation cc w/ enclosure:
' Mr. L. Gifford 7 b 11 g10 4 0 p General Electric Company 4720 Montgomer) Lane
-Bethesda, Maryland 20014 k
.