i 0->C8d) i CONCORDIA COLLEGE MOORHEAD. MINNESOTA PHYSICS DEPARTMENT 11 October 1978 Mr.

A.

B.

Davis, Chief Fuel Facility and Materials Safety Branch United States Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137

Dear Mr. Davis:

7 U-Y 3 Re:

License No. SNM-773 Your letter 4 October 1978 to Daro3d Frantsvog With reference to the items in Appendix A of you letter:

(1) We conducted a leak test on 15 September 1978 with negative results.

We have entered a permanent notice in our rotating calendar, to insure that future leak tests will be carried out on schedule.

(2) We have posted a notice in the radioactive laboratory, saying that the documents listed in your Appendix A (item 2) are on file in our departmental files and are available.

(3) We have posted a copy of form NRC-3, as given in your Appendix A (item 3) in the radioactive laboratory.

Having taken these steps, we consider that we are now in i

compliance.

Thank you for your help.

Sincerely yours,

,rantsvogxawAm Darold J.

Chairman DJF/bjb

,gg32210)%0 CC: Darold Frantsvog

, g \\s Carl Bailey

,'s k

~

-