Discusses Review of Final Site Observational Work Plan & Draft Ground Water Compliance Action Plan for Riverton,Wy, Title I Umtra Site
ML20197C345
Person / Time
Issue date: 09/03/1998
From: Joseph Holonich
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Plieness R
ENERGY, DEPT. OF
References
REF-WM-60 NUDOCS 9809110105
Download: ML20197C345 (3)


Text

_ -.

geW%

[

p k

UNITED STATES

.g j

NUCLEAR REGULATORY COMMISSION f

WASHINGTON, D.C. 20066-4001 o

          • ,o September 3, 1998 Mr. Ray Plieness U.S. Department of Energy Grand Junction Office

)

2597 B 3/4 Road Grand Junction, CO 81503

SUBJECT:

REVIEW OF THE FINAL SITE OBSERVATIONAL WORK PLAN AND DRAFT GROUND WATER COMPLIANCE ACTION PLAN FOR THE RIVERTON, WYOMING, TITLE I UMTRA SITE

Dear Mr. Plieness:

1 The U.S. Nuclear Regulatory Commission (NRC) staff has reviewed the U.S. Department of Energy's (DOE's) Site Observational Work Plan (SOWP), which included the Draft Ground j

Water Compliance Action Plan, submitted by cover letter dated February 25,1998, for the Uranium Mill Tailings Remedial Action (UMTRA) Project site at Riverton, Wyoming. The review focused on the proposed ground-water remediation strategy for compliance with 40 CFR Part 192, and the technicalinformation presented in support of this strategy. This review does not imply a concurrence in the ground-water cleanup activities at the Riverton site, but is provided as a " fatal flaw" review of the proposed compliance strategy based on collected data and analyses presented in the final SOWP.

The final SOWP summarizes the results from a probabilistic ground water flow and transport model that is used to reduce the uncertainties associated with the proposed ground-water compliance strategy. The model results show that the uncertainty associated with the proposed ground water compliance strategy is acceptable. Therefore, the next step in the UMTRA process, the preparation of site specific ground-water National Environmental Policy Act (NEPA) document, can begin.

The ground-water compliance strategy recommended for the Riverton site is natural attenuation with institutional controls to limit exposure to the contaminated ground water during the g

recovery period, and verification monitoring to ensure the model predictions are accurate.

Hydrogeologic and geochemical data collected from the Riverton site and the results of the ground-water modeling indicates that the natural ground-water movement and geochemical Mbg processes will decrease contaminant concentrations to background levels or maximum concentration limits (MCLs) within 100 years. During that period of time, effective monitoring, institutional controls, and an alternative water supply will be maintained to prevent the use ground water in the affected aquifer for domestic consumption, stock watering, or i

crop irrigation.

  1. 1h?

n lf$

}' ?I 73

{'

9809110105 980903 F

PDR WASTE WM-60 PDR 1

e l*

+f R. Plieness '

The NRC staff has no technical objection to utilizing this compliance strategy at the Riverton site. If you have any questions concerning this letter, please contact the NRC Project Manager, Jim Park, at (301) 415-6699.

Sincerely, m

ins Joseph J. Holonich, Chief Uranium Recovery Branch Division of Waste Management Office of Nuclear Material Safety and Safeguards cc: D. Metzler i

I

. _ = -. -.

,,8 e

f R. Plieness,

The NRC staff has no technical objection to utilizing this compliance strategy at the Riverton site. If you have any questions conceming this letter, please contact the NRC Project Manager, Jim Park, at (301) 415-6699.

Sincerely,

[Signedby]

Joseph J. Holonich, Chief Uranium Recovery Branch Division of Waste Management Office of Nuclear Material Safety and Safeguards cc: D. Metzler DISTRIBUTION :

  • File Conter.

NMSS r/f URB r/f PUBLIC CNWRA ACNW MLayton CAbrams JPark DOCUMENT NAME: S:\\DWM\\ URB \\JEM\\SOWP.RIV URBjh OFC URB URErb 6 c.

kb7 DGikn JK ch NAME JGunn o

v DATE 9 / \\ /98 9/t/98 H

9 / 3/98 OFFICIAL RECORD COPY l