ML20197A969
| ML20197A969 | |
| Person / Time | |
|---|---|
| Issue date: | 02/19/1986 |
| From: | Norry P NRC OFFICE OF ADMINISTRATION (ADM) |
| To: | |
| References | |
| OMB-3150-0011, OMB-3150-11, NUDOCS 8610270431 | |
| Download: ML20197A969 (5) | |
Text
IJ ) '
t l
L Li 7 ^rn,
""""""" a 3 Request for 0MB Rev,iew f' /f [y h wgg;;a; y ew sc.,+ r p.a.
important Read mstructions before completnig form. Do not use the 5,ine SF 83 knd three copies of this form, the material to be reviewed, And for to request both an Executive Order 12291 review and approval urwier paperwork-three copies of the supporting statemes;t to.
the Paperwork Reduction Act Answer all questicra in Part 1. If this request is for review under E.O.
Of fice of Information and Regulatory Affairs 12291. co'np'ete Part il and sign the regulatory certificat.on. If this Office of Management and Budget request is for approval under the Paperwork Reduction Act and 5 CFR Attention Docket tabrary, Room 32ol 1320, skip Part 11, complete Part Ill and s;gn the paperwork cenification.
Wa' tuncton, DC 20503 PAR T 1.-Complete This Part for All Requests.
ilepartment/ agency and Hurcad/of fice ongenating requot
~~~ ~~
~
i 2. Agency code U.S. Nuclear Regulatory Commission 3
1 5 0
- 3. Name of person wrio can test answer questions r% Aid.rg t'i.s reque31 Ietephone rumber
~
Gunter Arndt
<301 ) 443-7893
- 4. Title of enformation collection or rulernak4rf 10 CFR 50, Domestic Licensing of Production and Utilization Facilities u egai aetic-t, va informat,on cowiion ei ruie w vreee arcs code. na#fraa a Ucc.Afoddi ~~ '~'
42 2201(o) _
use 6 Affected & uthc (cf.ccu# that app!g
$ C f ederalagencies or empigees
! O inei..a.,ais or r,ousehoira 3 0 r-m.
e O Non orof.t inst.tutioas 2 O stateor iocaiso,ernments 4 DC Bus neues or t ther for prot t 7 0 smau buvnesses or organuat ons PART ll.-Complete This Part Only if the Request is for OMil Review Under Executive Order 12291
- 7. Regula' ion identd er Number (RIN)
_ _ _ _ _. _ ~.-._ _ ___ _ __. oi. f onc assigned C h Typc cf subrmssnon (checai one on esh category)
Type of rewew requested Clas sificatiert Stage of development 10 5tandard 1
MJ;ct 1 U Frepo,ed or d'a'?
2 C Pending 2 C Nonmaior
." C F ralor mier.m f nai, with por>r poposal 3 C [mergenef e
3 C Fiv es or interirn fir v. w.trmt poor protu.af 4 U Statutory or judicialdead4ne
- 9. Cf H seoion attected Cf R
- 10. Du s th:s rerutatir,n contain rrportirg or reroece p y er.u remer;ts thM ret. ore OMO wprevel under the Paperwork Reduction At t
,j Yes
,,; fio and t CFH 1320' t
i
- 11. H a tr.90r ruie. 's INie a regut.ito'y m. pact mm a*t.u %c 5 1 Y Ye*
2 I[ f(2 It tk. c.d OtM aase the an.pC _ _
3 C Yet 4[ ho Certif; cal 6en for Regulatory Submissions in sobetbr g tr.a re-quest for Of.tu review. ti.c e me.1 e. wmy r o tm i iw tt e ;even'tn w: u r+ *, toat trw me;.or m.r ts c [ 0 12N1 a.1 ey a:v i e e e
n;I( y alere toes have f.e+'1 < OW e<* Mh bgnature ni g ref tsm est'acial Oa'ta s g.m.re ct a..tv o, q u,, gu%.,,. i,, t.u t 8610270431 860219
- 12. ( UMH l.se or$ )
stanceed I orm 8 5 im.
- P5 rama en hrm
. C e.
6 3 g.p' p.'*
?g 10 :n > Ma.in p r.n, t 3
.**b
$ (F 6e [ V(i et r i ;
e
v PART lli.-d:mpists This Part Only if ths RIqunt is f tr Apprcvil of a Cclisctirn cf infarmatien Qndsr_the Paperwirk Raducilin Act and 5 CFH 1320.
- 13. Abstract-Descrea ne+ds, w. ind af Mt.M publ.c in 50 words or less
" Nuclear powerplant safety, radiation monitoring" In 10 CFR Part 50, Appendix J, " Leakage Tests for Containments of Light-Water-Cooled Nuclear Power Plants," revised paragraph VII.B. would require each licensee and applicant for an operating license to submit a plan so NRC can approve a schedule for implementing the Appendix.
t4. Type of nformatien rchect'on (ched o.4 or c) i Inform 1 tion collections not containert on rules i O Regum,, sut-onn 2 O tmersenc, subm.ss.on(cert.r. car,on attacned; information collections contained ort rules 1
E sat.ng r-gw i'icn Inc cNNe p*mosem 6 Final or intenm 6nal without onor PPRM 7 Enter date of espected or actual Federat 4 @ tMtice of preposed rulerrAng(NPPM)
A O Regular subm6ssion Register pubiccation at this stage of rulemaning S O rinat neRu.n prevousi,0.t>aved B O Emergencv submission (cert,ncat,onattachedi (month. dar. rear > lay _1986
- 15. Tgpe of rev en renaestra (cr eck only one) 1 O Ne.tcoiie ton 4 O Re>nstatement of a previousiy approved coiiection for wnicn approvai has expired 2 @ Revision of a currently approved conection 3 O Entension of the esp. rat.on date of a currently approved collection 5
E osting cottection in use without an oMB contr01 number witnout anf change in 19e substance or en the method of col!Pction
- 16. Agency report forr number (s)(scclude sta-dardtophonst form nuinber(s))
- 22. Purpose of information collection (check as many as apply; I O Application for benefits ne 2 O Program evaivation
- 17. Annual reporting or o sclosu'e ourcen 3 0 ceneraipurposestatistics 1 Humber of respondents 4 CQ Regulatoryorcomphance 2 Number of responses per rescendent 5
Program planning or management 3 Totaf annual responses (one I t,mcilme 2) 6 0 Researen 4 Hours per res:,onse 7 O Aud't 5 Totat hours grine J t,rnes I,nel_
- 18. Annual recordheep'ng burden
- 23. Frequency of recordheeping or reporting (checir all thatapply) 1 Number of recor beepers 1E Recordkeeping 2 Annual hours pe' retordareper Reporting 3 Total recerdhee;urg t*ou". cme 1 t.mes ime 2) 2 O onoccasion 4 Recordheeping retertoi pno1 years 3 ] w,,gjy
- 19. Total annual bu' dan 4 C Monthly 5 0 quarteriy 1 Requeved (rene 175 plus rene 18 J) 6 0 semi-annuairy 2 in current oMB.rwento y U
3 Dif ference (i ne I tes s t<e 2/
7 O Annuarry Enplication of det'orense 8
B,entually 4 Program change 9 CO Otner(descrrDe): One time 5 Adjustm nt.
- 20. Current (most recent) OMH cr;nte01 nurnter or comment number
- 24. Respondents
- obligation to comply (check the s frongest ob6gattort thJr appftes) 3150-0011 1 O voiuntary
- 21. Requested espiration date 2
Required to obtain or retain a benefit 9/30/86 3 Jg u,no,,,,,,
- 25. Are the respondents pomanly educational agencies or institutions or is the onmary purpose of the collection related to Federal education prog
- 26. Does the igenC use sampang tn seiect respondents or does the agency recommand or prescnbe the use of sampling or statist Cal analysis C Yes b No by respondents 0, '5emahondonett:on
- 27. Regu!Jt authonty for he sti ppen ix J or
__ r u
- or, other (spec,ry;
CFR P5erwork Cettification in submitti.y this remt for 0*>9 approval, the agency head, the semer othc al or an authorited representative, certifies that the requirements of 5 ct R 1320. tne Privacy Act. statishc al standants r r darer.tweg, and any other appicebie erforrnation policy directives have been complied with Date S,gnature of procame ',c,ai r
bgnature of agera y head.19 wn.o' of f.< w er an authorized iepresentative Date Patricia G. Norry, Director e
M-/f'PS Office of Administration
/
-68 r
/
o ei m r; - m 776
,e, SUPPORTING STATEMENT FOR PROPOSED RULE 10 CFR 50, APPEN0!X J, QVII.B.
A.
JUST!FICATION 1.
Need for the Collection of Information.
The containments of all light-water-cooled reactor power plants must be periodically leakage tested. These leakage tests help assure that any radioactive materials released into the containment will be suitably contained and that releases to the outside environment will be small. The leakage test requirements are specified in 10 CFR 50, Appendix J, " Leakage Tests for Containments of Light-Water-Cooled Nuclear Power Plants."
Adoption of the amended rule would add the following reporting requirement in Paragraph VII.B.
By 180 days after the effective date of the amendment, each licensee and each applicant for an operating license shall submit a plan to the Director of the Office of Nuclear Reactor Regulation for implementing the amended Appendix. This plan is in place of a universal, automatic compliance date, and provides more flexibility to licensees in implementing the revised rule.
2.
Agency Use of Information.
Use of this implementation approach permits a more practical and orderly phasing-in of new Technical Specifications and Appendix J testing procedures than would otherwise be possible. NRC staff review and approval of implementation plan will be within 6 months of submittal.
3.
Reduction of Burden Through Information Technology.
There are no information technology applications which would I
reduce the burden associated with this information collection.
l l
t 4
Effort to Identify Duplication.
The information being requested is unique to NRC's activity and therefore there is no duplication. FILS was searched with negative results.
5.
Effort to Use Similar Information.
No similar information exists, since this report is an implementation schedule requested in lieu of arbitrarily imposing the revised rule immediately.
6.
Effort to Reduce Small Business Burden.
Nuclear power plant licensees, those affected by this reporting requirement, are not "small entities" as defined in the Regulatory Flexibility Act or The Small Business Administration at 13 CFR part 121.
7.
Consequences of Less Frequent Collection.
As a one-time only report, there is no less frequent collection.
8.
Circumstances Which Justify Variation From OBM Guidelines.
There are no special circumstances that require the collection to be conducted in a manner inconsistent with the guidelines in 5 CFR 1320.6.
9.
Consultations Outside the NRC.
The proposed rule revision is being published in the Federal Register for public comment, so all interested parties outside the NRC will have equal opportunity to provide input to the final rule.
10.
Confidentiality of Information.
No assurance of confidentiality of information has been requested or provided.
- 11. Justification for Sensitive Ouestions.
l No questions of a sensitive nature are being asked of the nuclear l
L
1 12.
Estimated Annualized Cost to the Federal Government.
Implementation schedules will be reviewed in lieu of exemption requests that would otherwise be submitted if the rule were made effective imediately and arbitrarily. However, taken over 3 years, the annualized cost of review and approval of 127 responses x 120 hours0.00139 days <br />0.0333 hours <br />1.984127e-4 weeks <br />4.566e-5 months <br /> x $60,00/hr 3 years would be $304,800.
13.
Estimate of Burden.
As a one-time only report, the annualized burden to nuclear a.
power plant licensees taken over 3 years would be 20,320 hours0.0037 days <br />0.0889 hours <br />5.291005e-4 weeks <br />1.2176e-4 months <br /> 3 years = 6773.3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> annually.
b.
As above, the annual cost, taken over 3 years would be 6773.3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> x $60.00/ hour which equals $406,398.00
- annually, c.
Estimated one-time reporting burden.
1.
Number of respondents = 127 (93 operating + 34 underconstruction) 2.
Number of responses per respondent = 1 3.
Total annual responses = 127 4.
Hours per response = 160 (2 weeks x 2 people to review rule, tech specs, plant schedules and layout, and write report) (Based on discussion with NRC Region).
5.
Total hours = 20,320 14.
Reasons for Change in Burden.
The rule change adds a one-time information collection requirement.
15.
Publication for Statistical Use.
This collection of information will not nave any results that
~
will be published for statistical use.
B.
COLLECTIONS OF INFORMATION EMPLOYING STATISTICAL METH005 Statistical methods are not used in the collection of information.