ML20196L479

From kanterella
Jump to navigation Jump to search
Summary of 880616 Meeting W/Util Re Pipe & Pipe Supports Seismic Design Methodology.Util Agreed to Reevaluate Piping & Pipe Supports According to SRP & Compare to Original Design Basis to Establish Margin of Difference
ML20196L479
Person / Time
Site: Browns Ferry  
Issue date: 06/29/1988
From: Joseph Kelly
NRC OFFICE OF SPECIAL PROJECTS
To:
NRC OFFICE OF SPECIAL PROJECTS
References
NUDOCS 8807070519
Download: ML20196L479 (5)


Text

=

Juns 29, 1988 P

k Docket Nos. 50-259/260/296 F

LICENSEE: Tennessee Valley Authority FACILITY:. Browns Ferry Nuclear Plant, Units 1, 2 and 3 1988 MEETING ON PIPE AND PIPE SUPPORTS SEISMIC

SUMMARY

OF JUNE 16,(TAC 00015, 00016, 00017)

SUBJECT:

DESIGN METHODOLOGY On June 16, 1988, members from the Office of Special Projects met with the staff of the Tennessee Valley Authority (TVA or the licensee) to discuss TVA's seismic design methodology for the piping and pipe supports at Browns Ferry. is the list of attendees. Enclosure 2 is a copy of the TVA handout on which the meeting was based.

The meeting was held as a' briefing for the s'taff by the licensee.

Following discussions with the staff, TVA agreed to re-evaluate the piping and pipe supports according to the-Standard Review Plan and then compare this to their original design basis to establish a margin of difference.

In a parallel effort, the staff agreed to evaluate plants of a similar vintage to Browns Ferry to determine the acceptance criteria. TVA and the staff are to meet again in early July to discuss the results of the above efforts.

Original Signed by Gerald E. Gears for Janet L. Kelly, Project Engineer TVA Projects Division Office of Special Projects

Enclosures:

1.

Attendance List i

2.

TVA Handout cc w/ enclosures:

See next page Distribution Docket File NRC PDR Local PDR Those on Attached List OSP:TVA/

OS T PE W/PM TVA:h HSims)

J s

SBlack 6/f(p8 6) r8 6/q88 8807070519 880629 DR ADOCK 05000259 PTciXC

DISTRIBUTION _,FOR MEETING

SUMMARY

DATED:

June 29, 1988 Facility:

Browns Ferry Nuclear Plant, Units 1, 2, and 3*

Docket File

.NRC PDR' '

Local PDR Projects Reading J. Partlow J. Axelrad S. Richardson S. Black B. D. Liaw J. Kelly G. Gears D. Moran M. Sinns F. McCoy W. S. Little J. Rutberg J. R. Fair T. Cheng)

ACRS (10 GPA/PA GPA/CA (M. Callahan) (5)

F. Miraglia l

E. Jordan P. Gwynn J. Scarborough

, T. Elsasser C. Ader TVA-Rockville BFN Rdg. File l

I

(

1 l

l l

l l

~.

~

ENCLOSURE 1

, LIST OF ATTENDEES JUNE 16, 1988 TVA/NRC MEETING Name Organization _

Telephone j205)729-5289 205 729-2677 Steve Kane BFN-Licensing T. C. Cruise BFN - CEB A. W. Chan BFN - SWEC 205) 351-4101 Karl S. St. idle TVA - CEB 632-3745 John McCall TVA - CEB 632-2357 Janet Kelly NRC - OSP 492-0753 John R. Fair NRC - OSP 492-0763 Thomas Cheng NRC - OSP 492-0710 Phil Polk TVA - Rockville 492-0710 Gerry Gears NRC - OSP (301 492-0767

,p Enclosura 2 l

BROWNS FERRY PIPE AND PIPE SUPPORXS SEISMIC DESIGN METHODOLOGY FACTORS BF ORIGINAL DESIGN BASIS 1.

Vertical Seismic 0.07g OBE Response Input 0.13g SSE 2.

Seismic Damping 1/2% OBE

)

1% SSE 3

Peak Broadening NO 4.

Seismic Anchor Motn.

Some (1) 5.

ARS Elev. of Input C.G.

6.

ZPA Effects No 7.

Combination of Modes SRSS Combination of Dir.

8.

Closely Spaced Modes NO 9.

Rigid Range 20Hz or 30 Modes (1)

Between buildings and sourew pipe movement.

l

[

Browns Ferry Nuclear Plant Units 1; 2, and 3 I

i

(

l'

' General Counsel cc:

Regional Administrator, Region II v

Tennessee Valley Authority U.S. Nuclear Regulatory Comission 400 West Summit Hill Drive 101 Marietta Street, N.W.

/'

Eli B33 Atlanta, Georgia 30323 Knoxville, Tennessee 37902 Resident Inspector / Browns Ferry NP Mr. R. L. Gridley U.S. Nuclear Regulatory Comission Tennessee Valley Authority Rovte 12 Box 637 SN 1578 Lookout Place Atbans, Alabama 35611 Chattanooga, Tennessee 37402-2801 Mr. Richard King Mr. H. P. Pomrehn c/o U.S. GAO Tennessee Valley Authority 1111 North Shore Drive Browns Ferry Nuclear Plant Suite 225, Box 194 P.O. Box 2000 Knoxville, Tennessee 37919 Decatur, Alabama 35602 Dr. Henry Myers, Science Advisor Mr. M. J. May Committee on Interior Tennessee Valley Authority and Insular Affairs Browns Ferry Nuclear Plant U.S. House of Representatives P.O. Box 2000 Washington, D.C.

20515 Decatur, Alabama 35602 Mr. D. L. Williams Pr. S. A. White

- Tennessee Valley Authority Manager of Nuclear Power 400 West Sumit Hill Drive Tennessee Valley Authority W10 B85 6N 38A Lookout Place Knoxville, Tennessee 37902 1101 Market Street Chattanooga, Tennessee 37402-2801 Chaiman, Limestone County Comission P.O. Box 188 Athens, Alabama 35611 Claude Earl Fox, M.D.

State Health Officer State Department of Public Health State Office Building Montgomery, Alabama 36130 I

-