ML20196J799

From kanterella
Jump to navigation Jump to search
Forwards Reactor Containment Bldg Integrated Leak Rate Test. Next Type a Test for Unit Scheduled for Summer 1989
ML20196J799
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 02/22/1988
From: Bax R
COMMONWEALTH EDISON CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML20150C157 List:
References
RLB-88-54, NUDOCS 8803150061
Download: ML20196J799 (1)


Text

Commonwealth Edison ouad Cities Nuclear Power Station 22710 206 Avenue North Cordova. Illinois 61242 Telephone 309/654-2241 RLB-88-54 February 22, 1988 Mr. Harold Denton Director Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Hashington, D.C.

20555

SUBJECT:

Reactor Containment Building Integrated Leak Rate Test Quad-Cities Nuclear Power Station Docket No. 50-254, DPR-29, Unit One Enclosed please find the report "Reactor Containment Building Integrated Leak Rate Test, Quad-Cities Nuclear Power Station, Unit One, December 5-6, 1987" and the related appendices describing the Type A test.

The performance of this test was witnessed and inspected by representatives of.the NRC Region III Office.

Th,is report.is submitted to you in accordance with the requirements of 10 CFR 50, Appendix J, Section V.B.l.

The information contained in Appendix A of this report is intended to comply with requirements of 10 CFR 50, Appendix J, Section V.B.3.

According to.10 CFR 50, Appendix J, Section III. A.6, the test schedule for the next Type A test is to be reviewed and approved by the Commission.

The next Type A test for Quad-Cities Unit One is scheduled for the summer of 1989; the Commission's review and approval of this schedule is hereby requested.

Very truly yours, COMMONWEALTH EDISON COMPANY Quad-Cities Nuclear Power Station M

R. L. Bax 0l7 Station Manager NJK/KRS/dak Attachment 0483H/0214Z 8803150061 88A%QA PDR ADOCK 05000254 P

DCL k