ML20196J687

From kanterella
Jump to navigation Jump to search
Forwards SER for Completion of Lower Core Support Assembly & Lower Head Defueling. Separate Activity Has Been Added to Table to More Precisely Reflect Activities Associated W/Reactor Vessel Defueling
ML20196J687
Person / Time
Site: Crane 
Issue date: 06/27/1988
From: Standerfer F
GENERAL PUBLIC UTILITIES CORP.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20196J692 List:
References
4410-88-L-0100, 4410-88-L-100, NUDOCS 8807060431
Download: ML20196J687 (2)


Text

.a w

GPU Nuclear Corporation u Nuclear

,o r a da Middletown, Pennsylvania 17057 0191 717 944 7621 TELEX 84 2386 Writer's Direct Dial Number:

(717) 948-8461 June 27, 1988 4410-88-L-0100/0253P US Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

Dear Sirs:

Three Mile Island Nuclear St etton, Unit 2 (TMI-2)

Operating License No. DPR-73 Docket No. 50-320 Safety Evaluation Report for Completion of Lower Core Support Assembly and Lower Pead Defueling - Revision 1 GPU Nuclear letter 4410-08-L-0006 dated June 6,1988, submitted the Safety Evaluation Report for Completion of Lower Core Support Assembly and Lower Head Defueling for NRC review and approval. Section 5.0, "Radiological Conditions" of that submittal comitted to provide an update of the expected occupational exposure to complete Reactor Vessel (RV) defueling and the jobhours and person-rem expended to date for defueling activities.

Attached, as Revision 1 to the subject document, is that information. Only the affected pages of the original document are provided (i.e., pages 3, 18 - 27).

GPU Nuclear currently estimates that approximately 1580 person-rem (i.e., an increase of 180 person-rem) will be required for completion of RV defueling.

This increase is primarily due to an increase in defueling support activities such as operation and maintenance of the Automated Cutting Equipment System.

A revised Table 5-1, updated to May 31, 1988, indicates that 1028 person-rem l

have been expended for RV defueling activities. A separate activity, entitled l

"Defueling Support," has been added to this table to more precisely reflect the activities associated with RV defueling.

Sincerely, 1

8807060431 080627

/

(

y PDR ADOCK 050 0

. R. Standerfer Director, TMI-2 5

RDW/ emf s\\

GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation l

m.

.n.

~ _.

.i-t-

s g-ry -

t o

s l N

.? ocument Control De'sk.. 4410-88-L-0100 D

June ' 27, '1988 g

iAttachment V

Senior Resident Inspector, THI - R. J. Conte -

cc: :

. Regiona1' Administrator,~ Region 1 -.W. T. Russell

-Director, Plant-Directorate IV:-.J. F. Stolz

- Systems Engineer, TMI Site - L. H. Thonus 4

a p

p+

I' k

i i

i l

l t-t i

I l

f t

l i

1 1

f * *,

y_w.,w--,

-.,,e--.=wy

.,,,ew,,

,y-,.,r-%v m.--

er mm

-wm-vm

,e-ow,vw w.=,

wow 1vw e -- w rvwve ~er ~ g e+++,r

,- ee r w er e e e v- -+

-+r v r w+ "g w-e et