Amend 213 to License DPR-50,revising TMI-1 TS 6.12.1 to Approve Alternative High Radiation Area Control Consistent with RG 8.38
ML20196J585
Person / Time
Site: Crane 
Issue date: 07/01/1999
From: Bajwa S
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20196J590 List:
References
RTR-REGGD-08.038, RTR-REGGD-8.038 NUDOCS 9907070361
Download: ML20196J585 (4)


Text

p g >* REQ t

[1 UNITED STATES j

,j NUCLEAR REGULATOR) COMMISSION l

1#

WASHINGTON, D.c. 20555-0001 l

METROPOLITAN EDISON COMPANY JERSEY CENTRAL POWER & LIGHT COMPANY l

PENNSYLVANIA ELECTRIC COMPANY GPU NUCLEAR. INC.

i DOCKET NO. 50-289 THREE MILE ISLAND NUCLEAR STATION. UNIT NO.1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 213 License No. DPR-50 1.

The Nuclear Regulatory Commission (the Commission or NRC) has found that:

A.

The application for amendment by GPU Nuclear, Inc., et al. (the licensee) dated, June 11,1998, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance: (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the l

Commission's regulations and all applicable requirements have been satisfied.

1 9907070361 990701 j

PDR ADOCK 05000289 P

l pg

- 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.c.(2) of Facility Operating License No. DPR-50 is hereby amended to read as follows:

(2). Technical Soecifications The Technical Specifications contained in Appendix A, as revised through Amendment No.213, are hereby incorporated in the license. GPU Nuclear, Inc.

shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of its date of issuance, and shall be implemented within 30 days of issuance.

FOR THE NU, CLEAR REGULATORY COMMISSION 4

S. Singh Bajwa, Chief, Section 1 Project Directorate i Division of Licensing Project Management Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Isstiance: July 1, 1999 I

e 1

ATTACHMENT TO LICENSE AMENDMENT NO. 213_

FACILITY OPERATING LICENSE NO. DPR-50 DOCKET NO. 50-289 Replace the following page of the Appendix A, Technical Specifications, with the attached revised page. The revised page is identified by Amendment number and contains marginal lines indicating the areas of change.

Remove Insert 6-22 6-22 i

I i

i l

7 m

L i

6.'l 1 RADIATION PROTECTION PROGRAM i

i L

Procedures for personnel radiation' protection shall be prepared consistent with the requirements of 10 CFR Part 20 and shall be approved, maintained and adhered to for all operations involving l

' personnel radiation exposure.

l

' 6.12 - HIGH RADIATION AREA-L 6.12.1 In lieu of the " control device" or " alarm signal" required by paragraph 20.1601 of 10 CFR 20; Each tiigh Radiation Area in which the intensity of radiation at 30 cm (11.8 in.)

a.

is greater than 100 mrem /hr, deep dose but less than 1000 mrem /hr. shall be barricaded and conspicuously posted as a High Radiation Area, and personnel desiring entrance shall obtain a Radiation Work Permit (RWP). Any individual or group ofindividuals entering a High Radiation Area shall (a) use a continuously indicating dose rate monitoring device or (b) use a radiation dose rate integrating device which alarms at a pre-set dose level (entry into such areas with this monitoring device may be made after the dose rate level in the area has been established and personnel have been made knowledgeable of them), or (c) assure that a radiological control technician provides positive control over activities within the area and periodic radiation surveillance with a dose rate monitoring instrument.

b.

In addition to the requirements of specification 6.12.1.a:

l

1. Any area accessible to personnel where an individual could receive in any one hour a deep dose in excess of 1000 mrem at 30 cm (11.8 in.) but less l

than 500 rads at one meter (3.28 ft.) from sources of radioactivity shall be

' locked or guarded to prevent unauthorized entry. The keys to these locked barricades shall be maintained under the administrative control of the respective Radiological Controls Supervisor.

2. For individual high radiation areas where an individual could receive in any one hour a deep dose in excess of 1000 mrem at 30 cm (11.8 in.) but less j

than 500 rads at one meter (3.28 ft.), that are located within large areas i

such as reactor containment, where no enclosure exists for purposes of.

locking, and where no enclosure can be reasonably constructed around the 1

individual area, that individual area shall be barricaded and conspicuously posted, and a flashing light shall be activated as a warning device.

The Radiation Work Permit is not required Ny Radiological Controls personnel during the performance of their assigned radiation protection duties provided they are following radiological control procedures for entry into High Radiation Areas.

6-22

- Amendment' Nos. !1. 35,72,77,106,107,129, !?3,180, 213 4

!