ML20196H113

From kanterella
Jump to navigation Jump to search
Applicant Suggestion of Mootness.* Order Should Enter Finding That Issue Re Environ Qualification of RG-58 Coaxial Cable Pending Before Licensing Board Moot
ML20196H113
Person / Time
Site: Seabrook  
Issue date: 05/27/1988
From: Steenland D
PUBLIC SERVICE CO. OF NEW HAMPSHIRE, ROPES & GRAY
To:
Atomic Safety and Licensing Board Panel
Shared Package
ML20196G977 List:
References
OL-1, NUDOCS 8807060089
Download: ML20196H113 (6)


Text

_ _ _ _ _ - _ _.

1 i

May 27, 1933 I

UNITED STATES OF AMERICA UNITED STATES NUCLEAR REGULATORY COMMISSION j

I before the ATOMIC SAFETY AND LICENSING BOARD

)

In the Matter of

)

)

PUBLIC SERVICE COMPANY

)

Docket Nos. 50-443-OL-1 NEW HAMPSHIRE, et al.

)

50-444-OL-1

)

(Seabrook Station, Units 1

)

(On-site Emergency and 2)

)

Planning Issues)

)

APPLICANTS' SUGGESTION OF MOOTNESS On the basis of the Affidavits of Richard Bergeron, Gerald A. Kotkowski and Ted C.

Feigenbaum and for the reasons set forth below, Applicants move the Licensing Board to enter an order that the issue regarding the environmental qualification of RG-58 coaxial cable pending before this Licensing Board is moot.

As is established by the Affidavit of Richard Bergeron, the RG-58 cable is a coaxial, single conductor cable which is non-vital, or nonsafety-related.

Beraeron Affidavit at $5 3-4.

A computer run was made to generate a list of all installed RG-58 coaxial cables at Seabrook Station and 126 nonsafety-related cables were identified.

Id. at 11 3-6, FBO70600B9 080628 PDR ADOCK 05000443 O

PDR j

_ _ _l

The route of each cable identified was traced by means of Seabrook Station cable raceway drawings.

Id. at 1 7.

In addition to tracing the route of the identified RG-58 coaxial cable, a review was performed to determine if the other cables routed along with the RG-58 cable (s) were safety-related or nonsafety-related.

Id.

Information regarding the RG-58 cable routes, the physical interactions with other cables (i.e. other cables routed with RG-58 cables) and environmentil zones and parameters of the routes was evaluated to identify common groupings of cables.

Id. at 15

-9.

The 126 nonsafety-

/9 p' ced into the following related RG-58 cables categories:

No. of Cables Catecorv 19 Spare RG-58 cables 12 RG-58 cables routed at least partially through a harsh environment within the nuclear island (see FSAR Figure 8.3-58) 76 RG-58 cables located in mild environrents within the nuclear island 10 RG-58 cables routed with other nonsafety-related cables outside the nuclear island 9

RG-58 cables routed in mild environments within the nuclear island and routed with nonsafety-related cables outside the nuclear island Id. at 1 9.

It should be noted that none of the RG-58 cables are routed inside the Containment Building or in the main steam and feedwater pipe chases.

Id. at 1 10.

The only RG-58 coaxial cables uhich must meet the environmental qualification set forth in 10 CFR 50.49 are the twelve (12) nonsafety-related RG-58 coaxial cables which are routed at least partially through a harsh environment within the nuclear island.

The RG-58 cables located in mild environments are not required to be qualified under 10 CFR 50.49 as 10 CFR 50.49(c) provides that "environmental qualification of electric equipment important to safety located in a mild environment (is) not included within the scope of this section."

Furthermore, the nonsafety-related RG-58 cables which are routed with other nonsafety-related cables outside the nuclear island are not required to conply with the requirements set forth in 10 CFR 50.49 as 10 CFR

50. 4 9 (b) (2) provides that the electric equipment covered by the regulations includes "nonsafety-related equipment whose failure under postulated environmental conditions could prevent satisfactory accomplishment of safety functions...by the safety-related equipment."

Finally, the spare cables are not required to meet the requirements of 10 CFR 50.49 as the spare cables are not functioning or energized and therefore do not pose any threat to other cables in the same raceway.

Id. at 1 14.

Egg also id. at 11 12-15.

An independent review was performed and verified that:

(1) all RG-58 cables were identified; and (2) there were only tw61ve nonuafety-related RG-58 cables which were routed at least partially through a harsh environment within the nuclear island.

Id. at 1 16.

An additional review was performed and verified that the raceway drawing used reflected the as-built installed raceway configuration.

Id.

at 1 17.

As is established by the Affidavit of Gerald A.

Kotkowski, the RG-59 coaxial cable is an acceptable substitute for the twelve RG-58 cables located in a harsh environment within the nuclear island.

A revieu was performed to determine the applications of the twelve RG-58 cables which are located in harsh environments within the nuclear island.

Kotkowski Affidavit at 1 3.

It was determined that the applications of the RG-58 cable fall into two groups which are nonsafety-related/non-essential.

Id.

In both cases the intended function of the cable is to transmit high frequency electrical signals.

Id.

A review of factory test results for both the RG-58 cable and the RG-59 cable demonstrated that the RG-59 cables will retain equal or better signal quality than the RG-58 cable for t'aese twelve applications.

Id. at 11 4-6.

In addition, the RG-59 cable was found to be compatible with the requirements of the connecting device / instrument used by the RG-58 cable' Id. at

s 1

1 7.

It was therefore determined that the RG-59 coaxial cable was an acceptable substitute for the twelve RG-58 cables located in a harsh environment within the nuclear island.

Id. 1 8.

The environmental qualification of the RG-59 cable for the postulated accident conditions inside the containment at Seabrook Station was established by means of testing and is contained in Environmental Qualification File No. 113-19-01.

Berceron Affidavit at 1 19.

Therefore, the RG-59 coaxial cable is qualified for the harsh environment RG-58 cable applications.

Id.

Finally, as is established by the Affidavit of Ted'C.

Feigenbaum, the management of Seabrook Station has determined that given the small quantity of cable involved, the licensing process would be better served by replacing the RG-58 cables in the twelve applications where the cable needs to meet the requirements of 10 CFR 50.49, rather than to continue to litigate the issue of the environmental qualification of the RG-58 cable.

Feicenbaum Affidavit at 11 2-5.

New Hampshire Yankee, therefore, has directed that for the twelve RG-58 coaxial cable applications, the RG-58 coaxial cable will be replaced by RG-59 coaxial cable.

Id. --

at 1 7.

The replacement of the cable will be completed prior to the issuance of an operating license authorizing power operations up to and including 5% power.

Id. at 8.

CONCLUSION An order should enter finding that the issue regarding the environmental qualification of RG-58 coaxial cable pending before this Licensing Board is moot.

Respectfully submitted, d

d4 Thomas G.

Dignan, Jr.

Deborah S.

Steenland Ropes & Gray 225 Franklin Street Boston, Massachusetts 02110 (617) 423-6100 counsel for Applicants

.