ML20196G201

From kanterella
Jump to navigation Jump to search

Forwards Application for Amend to License NPF-3,revising Tech Specs,Involving Section 3/4.3.2, Safety Sys Instrumentation,Steam & Feedwater Rupture Control Sys Instrumentation & Section 3.3-11.Fee Paid
ML20196G201
Person / Time
Site: Davis Besse 
Issue date: 02/29/1988
From: Shelton D
TOLEDO EDISON CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20196G207 List:
References
1461, TAC-66732, NUDOCS 8803070077
Download: ML20196G201 (1)


Text

'*

TOLEDO EDISON A Catara Eg Cm Docket No. 50-346 DONALD C. SHELTON License'No. NPE-3 vc. amw w (419]P49. m 1 Serial No. 1461 February 29, 1901 United States Nuclear Regulatory Commission Document Control Desk Washington, D. C.

20555 Subject License Amendment Application to Revise the Steam and Feedwater Rupture Control System Main Steam Low Pressure Block Permit Setpoint (TAC No. 66732)

Centlemen:

The eclosed application requests that the Davis-Besse Nuclear Power Station, Unit No. 1 Opereting License, Appendix A, Technical Specifica-tions be revised to reflect the changes attached. The 1,roposed changes involve Section 3/4.3.2, Safety System Instrumentation Steam and Feedwater Rupture Control System Instrumentation, Table 3.3-11, Steam and Feedwater Rupture Control System Instrumentation.

The proposed changes would rodify the Steam and Feedwater Rupture Control System (SFRCS) Main Steam (MS) low pressure block permit setpoint from 650 psig to 700 psig and increase the steam pressure setpoint where the block permit is autoniatically removed from 650 psig to 750 psig. These chcnges will increase the pressure margin between the SFMS block permit and the SFRCS MS low pressure trip setpoints. This will minimize the possibility of an inadvertent ;iS low pressure trip from occurring during plant cooldown and heatup operations.

Toledo Edison requests that this amendment be issued by July 15, 1988 for implementation prior to Cycle 6 operation.

Enclosed is a check for (150.00 as required hv 10CFR170.12(c) for a License Amendment Application.

Very crul* yours, D

Enclosures cc: DB-1 NRC Resident Inspector A. B. Davis, Regional Administrator (2 copies)

State of Ohio

/

A. W. DeAgazio, NRR Davis-Besse Project Manager 0

THE T%EDO EDGON COMPANY EDISON PLAZA 300 MADrSON AVENUE TOLEDO OHIO 43652 8

0'#

8803070077 880229 gab g,g/cjgf:g PDR ADOCK OC000346 P

DCD

7F~8754M-

)