b.
[ga arouq'o UNITED STATES l 3 y
~}4 NUCLEAR REGULATORY COMMISSION g,
- E WASHINGTON, D. C. 20555
\\...../
Dl!00ESNE LIGHT COMPANY OH10 EDI_S,0,N,_ COMPANY PENNSYLVAN_IA POWER C0_MPANY DOCKET NO. 50-334 BEAVER VALLEY P0_WER__STATIOL UNIT N0. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendn.ent No.127 License No. DPP-6f 1.
The Nuclear Regulatory Conission (the Corranission) has found that:
A.
The application for amendnent by Duquesne Ldght Conpany, et al.
(the licensee) dated August ??,1986, suppleniented by letter dated April 16, 1987, complies with the standards and requirenents of the Atomic Energy Act of 1954, as amended (the Act) and the Consaission's rules and regulations set forth in 10 CFR Chapter I; i
B.
The facility will operate in conformity with the applicatien, the provisfors of the Act, and the rules and regulations of the Conrission; C.
There is reasonable assurance (1) that the activities authorized by this anendnent can be conducted without endangering the health and safety of the public, and (ii) that such activities will be i
conducted in compliance with the Cortnission's regulations; I
D.
The issuance of this amendment will not be inimical to the conson defense and security or to the health and safety of the public;
(
and
{
E.
The issuance of this amendn:ent is in accordance with 10 CFR Part 1
51 of the Connission's regulations and all applicable requirements have I an satisfied, l
l OOO70 g g $
00p 1
?
'~ 2.
Accordingly, the license is amended by changes to the_ Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-66.is hereby amended to read as follows:
(2) Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No.127, are hereby incorporated ir, the license.
The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective on isssuance, to be implemented within 30 days of issuance.
FOR THE NUCLEAR REGULATORY C0ftMISSION f
I
(.
,-v J hn F. Stolz, Director I
r ' c+ 91 rectorate I-4 Dh it '
of Reactor Projects I/II Offic-Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance:
June 22, 1988 l
l
ATTACHMENT TO LICENSE AMENDMENT NO.122__
FACILITY OPERATING LICENSE N0. DPR-66 DOCKET NO. 50-334 Replace the following page of the Appendix A Technical Specifications with the enclosed page as indicated. The revised page is identified by.
amendment number and contains vertical lines indicating the areas of change.
Remove Insert 3/4 6-199 3/4 6-199
~
I l
}
O
^
a TABLE 3.6-1 COttfAlittENT PENFTRATIONS em N
HAXIHllH HAXIHilH N
PENT.
INSIDE STROKE OUTSIDE STROKE NO.-AREA IDENTIFICATION /DESCFTPTION VAI.VE TIHE*(SEC)
VALVE TIHE* (S EC)
U 78-SgD FW Ioop IC Closed System N/A (2)HOV-IFW-156C 75 4
FW Ioop IC Closed System N/A (2)FCV-IFW-498 10 r2 FW Loop IC Closed System N/A (6)HOV-lFW-158C N/A 0-Auxtllary Feedwater Loop IC Closed System N/A (2)HOV-lFW-151A N/A Auxillary Feedwater I.oop IC Closed System N/A (2)HOV-!FW-151B N/A e-a 79-SgD RW to IA RSP lix Closed System N/A (2)HOV-IRW-104A N/A 80-SgD RW to IC RSP lix Closed System N/A (2)HOV-IRW-10(C N/A 1
l 81-SgD RW to IB RSP 11x Closed System N/A (2)HOV-IRW-104B N/A
(
82-SgD RW to ID RSP Ilx Closed System N/A (2)HOV-lRW-104D N/A I
8 3-SgD RW from LA RSP lix Closed System S/A (2)HOV-lRW-105A N/A 84-SgD RW from IC RSP IIx Closed System N/A (2)HOV-IRW-103C N/A 85-SgD RW from IB RSP lix Closed System N/A (2)HOV-IRW-105B H/A 86-SgD RW from ID RSP lix Closed System
"'A (2)HOV-IRW-10$D N/A l[
8 7-SgD H Discliarge to'CNHT N/A IHY-Ill N/A 2
a 1 Hy-197 88-SgD 11 Placlearge t CNHT N/A IHY-110 N/A 2
l HY-196 o
89-SgD Hain Condeurer Ejector Vent IAS-278 N/A (B)TV-ISV-100A 20 f
90-SgD CNHT Purge Exinaust VS-D-5-35 (5)8 VS-D-5-3A (5)8 91-SgD CNNT Purge Supply VS-D-5-5 B (5)l1 VS-D-5-5A (5)8 E$
VS-D-5-6 N/A