Safety Evaluation Supporting Amend 10 to License NPF-36
ML20196E596
Person / Time
Site: Shoreham File:Long Island Lighting Company icon.png
Issue date: 11/30/1988
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20196E570 List:
References
NUDOCS 8812120043
Download: ML20196E596 (4)


Text

_ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _.

p asg'o UNITID STATES

~,%

NUCLEAR REGULATORY COMMISSION W ASHINGTON, D. C. 20555

\\,,,,,/

SAFETY EVALUATION RY THE OFFICE OF NUCLEAR REACTOR REGULATIAN SUPPORTING AMENDMENT NO.

10 TO FACILITY OPERATINr. LICENSE NO. NPF-36 LONG ISLAND t.!GHTING COMPANY SHOREHAM NUCLECA POWER STATION DOCKET NO. 50-3??

f

1.0 INTRODUCTION

By letter dated September A.1987, as supplemented November 19, 1987 Long Island Lighting Company (the licensee) requested an amendment to Facility Operating License No. NPF-36 for the Shoreham Nuclear Power l

Station. The proposed *.mendment would change the definition of core alteration in the Technical Specit cations (TSs) to include certain I

exceptions and change footnotes in the TSs to be consistent with the new definition.

2.0 EVALUATION f

]

Definition of Core Alteration

[

The following changes to the TSs would be made:

i a.

The definition of core alteration would be modified to exclude nomal movement of the source range monitors (SRMs), intennediate range j

monitors (IRMs), or transversing in core probes (TIPS).

I b.

The "*" footnote to Specification 3.1.1 on shutdown margin would be i

modified by deleting the exception to the core alteration definition l

for the movement of SRMs and IRMs. This footnote provides an exception to the core alteration definition for movement of IRMs.

i SRMs or special movable detectors. The exception for movement of j

special moveable detectors remains and is not affected by this change.

c.

A **" footnote to Specification 4.1.2a on reactivity anomalies would be added to allow an exception to the core alteration definition for movement of control rods via their normal drive systems.

d.

The "*" footnote to Surveillance Requirement 4.1.3.24 would be l

modified by deleting the exception to the core alteration definition

+

j for the movement of SRMs. IRMs or special movable detectors. The i

1 exception for nomal control rod movement remains and is not l

affected by this proposed change.

l I

8012120043 $S11:e FDR ADOCK 05000322 i

P PDC

2 t

e.

The "*" footnote to Table 3.3.1 1 would be modified by deleting the exceptions to the core alteration definition for IRMs and SRMs. The part of the "*" footnote requiring operable SRM instrumentation for renlacement of LPRM strings would be retained, f.

The "*" footnote to Specification 3.9.2 on refueling operation instrumentation would be provided by deleting the exception to the core alteration definition for the movement of SRMs and IRMs. This L

l footnote provides an exception to the core alteration definition for movement of IRMs. SRMs. or special moveable detectors.

The exception for movement of special moveable detectors remains and is not affected by this change, f

g.

The "*" footnote to Specification 3.9.5 and 4.9.5 on refueling operation cortounication would be modified by deleting the exception to the core alteration definition for incore instrumentation.

The part of the "*" footnote that allows an exception for control rod r

j movement with their normal drive system remains and is not affected by this proposed change.

l The present definition of core alteration is:

l

)

"Core alteration shall be the addition, removal, relocation or l

movement of fuel, sources, incore instruments or reactivity controls 4

within the reactor pressure vessel and the vessel head removed and i

fuel in the vessel.

Suspension of core alterations shall not l

preclude completion of the movement of a component to a safe

+

J conservative position".

)

The proposed change would insert the following after the first sentence:

[

"Normal rovement of the SRMs. IRMs. or TIPS. in the driving system

]

is not considered a core alteration".

The exception to the present definition of core alteration for the normal moversent of the SRMs. IRMs. LPRMs. TIPS, and special moveable detectors

)

is needed in certain specifications related to refueling operations in

[

order to preclude unnecessary suspension of the normal movement of these t

detectors.

During a refueling outage, maintenance or modification of equipment can result in TS limiting condition for operation which require that core alteration be suspended.

In the present TSs. exceptions to the I

definition of core alteration for normal movement of detectors are provided by footnotes in those TSs where a need for the exception was i

foreseen.

1 l

However, some TSs that require suspension of core alterations do not

(

J presently have a footnote excepting normal movement of detectors.

For l

l example. Specification 3.8.1.2 requires suscension of core alterations j

when the Limiting Conditions for Operation are not met. With the present i

I l

3-TSs, surveillance tests of SRMs and IRMs would not be perfomed because the tests require movement of the detectors.

Making the exception a part of the definition will correct this type of operational problem. Where patiticular conditions are required for nomal movement of detectors, the', conditions are retained in the applicable TSs.

For example, the requ,fement for SRMs to be operable when replacing LPRMs is retained in Specification 3/4.3.1, "Reactor Protection System Instrunentation".

The NRC staff has reviewed the proposed changes to the SNPS TSs related tc core alterations. The detectors in the SRM, IRM, and TIP are sealed unit fission detectors and their reactivity worth is insignificant with respect to reactivity excursion events. Therefore, allowing the nomal movement of these detectors will not significantly increase the probability or consequences of an accident previously analy:ed in the Final Safety Analysis Report.

The proposed change would only permit nomal movement of the incore detectors. Normal movement of these detectors includes insertion and withdrawal using detector drives, and replacement of detectors. The Mdition, removal or relocation of SRMs.

IRMs, and TIPS would still be prohibited.

The staff :

r'udes that the proposed changes to the definition of core alteration, an. the deletion references to SRMs, IRMs, and incore instrumentation in certain footnotes in the TSs for consistency with the new definitions and addition of a footnote to reduce the surveillance requirerents for reactivity anomaly after core alteration conditions (Operational Condition 5) during which no core changes occur but only movement of control rods in their drive mechanism would not significantly reduce the level of safety and would enhance safety by making the TSs more readable. Accordingly, the proposed changes are acceptable.

3.0 FNVIRONMENTAt. CONSIDERATION This amendment involves a change to a requirement with respect t.o the installation or use of a facility component located within the restricted area as defined in 10 CFR Part 20 and changes to the surveillance requirements.

The staff has detemined that the amendment involves no significant increase in the amounts, and no significant change in the types, of any effluents that may be released offsite and that there is no significant increase in individual or cumulative occupational radi3 tion exposure. The Comission has previously issued a proposed finding that this amendment involves no significant hazards consideration and there has been no public coment on such finding. Accordingly, this amendment meets the eligibility criteria for categorical exclusion set fortn in 10 CFR 51.22(c)(9).

Pursuant to 10 CFR 51.22(b), no environmental impact statement nor envirer, mental assessment need be prepared in connection with the issuance of this amendment.

c.

-4

4.0 CONCLUSION

The Commission made a proposed determination that the amendment involves no significant hazards consideration which was published in the Federal Register (52 FR 47785) on December 16, 1987 and consulted with the State of New York.

No public comments were received, and the State of New York did not have any comments.

The staff has concluded, based on the considerations discussed above, that:

(1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, and (2) such activities will be conducted in compliance with the Commission's 1

regulations and the issuance of this amendment will not be inimical to the i

common defense and the se urity nor to the health and safety of the public.