WM EE Log # 'iXX-88824 File # 10110

=

r 908.3 7UELECTRIC Ref.#10CFR50.f5(e) 3Cgg December 1, 1988 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.

20555 l

SUBJECl:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET N05. 50-445 AND 50-446 CABLE INSUI.^. TION RESISTANCE - LOOP ACCURACY SDAR:

CP-h 19 (SUPPLEMENTAL REPORT)

Gentlemen:

l Oa January 29, 1988, TV Electric's report logged TXX-88143 notified you of a reportable deficiency involving the qualification of instrument cable 1

insulation inside containment. Our last supplemental report was logged TXX-88614, dated August 10, 1988.

This report is submitted to revise the j

corrective action implementation schedule.

TV Electric's engineering evaluation is continuing. Any required corrective acti)ns for Unit 1 will be.cheduled consistent with the associated system / area turnover dates, the latest of which is April 28, 1989.

The schedule for Unit 2 has not changed.

Very truly yours, TU$'?Ceasu)

W. G. Counsil cf h By:

R. D. Walker Manager, Nuclear Licensing CBC/gj

{

c - Mr. R. D. Martin, Region IV

[

ResidentInspectors,CPSES(3) 8812060152 881201 ADOCK0500ggg5 DR 4M North Ohw Suret LB 8I Della. Toxes 13MI

-