ML20195K438
| ML20195K438 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 11/30/1988 |
| From: | Counsil W TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| References | |
| CP-88-29, TXX-88812, NUDOCS 8812050215 | |
| Download: ML20195K438 (1) | |
Text
..T
--F%
Log # TXX-88812 1
Fi1e # 10110 r
=
910.4 7UELECTRIC Ref. # 10CFR50.55(e)
November 30, 1988 E.On?,S:u?rraY, san, U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.
20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET NOS. 50-445 AND 50-446 FEEDWATER SPLIT-FLOW BYPASS VALVES SDAR: CP-88-29 (SUPPLEMENTAL REPORT)
Gentlemen:
On April 22, 1988, TV Electric notified the NRC by our letter logged TXX-88384 of a deficiency involving a feedwater design modification which was not incorporated into the FSAR Chapter 15 accident analysis. Our last report on this issue was logged TXX-88761 dated October 31, 1988.
The purpsse of this supplemental report is to revise the corrective action implementation schedule.
Qualification of the feedwater split-flow bypass valve is continuing and will be complete by March 3, 1989.
J Very truly yours,,
l 0W W. G. Counsil JDS/gj c - Mr. R. D. Martin, Region IV Resident inspectors, CPSES (3) fE71 GG12050215 881130
/O ADOCK0500j4b_
DR 400 hrth Olns Street LB81 Ikilas. Teses 13.'0!