Supplemental Deficiency Rept CP-88-21 Re Jc White Instrument Tubing Clamps.Initially Reported on 880129.Estimated Completion Date for Implementation of Unit 1 Revised to 890628.Unit 2 Completion Date Has Not Changed
ML20195K410
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 11/30/1988
From: Counsil W
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
CP-88-21, TXX-88795, NUDOCS 8812050205
Download: ML20195K410 (1)


Text

a MFE Log # TXX-88795 File # 10110

=

=

903.9 N/ ELECTRIC Ref. # 10CFR50.55(e) s November 30, 1988

$$ESdN,u U. S. Nuclear Regulatory Commission Attn Document Control Desk Washington, D. C.

20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 INSTRUMENT TUBING CLAMPS SDAR: CP-88-21 (SUPPLEMENTAL REPORT)

Gentlemen:

On January 29, 1988, TV Electric letter logged TXX-88140 notified the NRC of a deficiency involving J. C. White tube clamps.

The last report on this issue, logged TXX-88621, was submitted August 10, 1988.

The purpose of this letter is to revise the corrective action implementation schedule for this issue.

The estimated completion date for implementation of the Unit 1 corrective acticns (stated in TX.v.88140) has been revised to June 28, 1989.

The Unit 2 scheduled completion desa has not changed.

Very truly yours, 0]l0C i

W. G. Counsil HAM /gj c - Mr. R. D. Martin, Region IV Resident Inspectors, CPSES (3)

$k 8S12050205 881130

{DR ADOCK 0500044$

do l

PDC 400 Nonk Obw Suret LB81 Dallas, Texss 73.41

-