ML20195G400

From kanterella
Jump to navigation Jump to search
Offers No Comments on Draft Environ Assessment of Remedial Action at Spook U Mill Tailings Site,Spook,Wy. Radon Flux Emanating from Stabilized Tailings Pile Complies W/Epa Stds for U Mill Tailings Remedial Control Act Projects
ML20195G400
Person / Time
Issue date: 05/25/1988
From: Tokar M
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Fliegel M
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
REF-WM-72 NUDOCS 8806270338
Download: ML20195G400 (1)


Text

_ - _ _ - _ _ _ _ _ _ _

N2 3 M MEMORANDUM FOR: liyron Fliegel, Section Leader Operations Branch Division of Low Level Waste Management and Decommissioning, NHSS

'OM:

Michael Tokar, Section Leader Technical Branch Division of Low-level Waste Management and Decommissioning, NHSS

SUBJECT:

DRAFT ENVIRONMENTAL ASSESSMENT OF REMEDIAL ACTION AT THE SPOOK URANIUM MILL TAILINGS SITE. SP0OK, WYOMING. REVIEW As requested, we have performed a review of the geotechnical engineering dspects of the report on Draft Environmental Assessment of Remedial Action at the Spook site.

Based on review of the information presented in the draft EA, we have no geotechnical engineering concern:, related to environmental assessment of the proposed actions at the Spook site.

The radon flux emanating from the stabilized tailings pile complies with the EPA Standards for UMTRCA projects. Also, the radon flux emanating from the AML cover material, if placed as per the proposed design, will comply with the EPA 6tandards.

Therefore, we have no conrents on this draft EA report.

This review was performed by Banad Jagannath; please contact him should you have any questions.

M Michael Tokar, Section Leader Technical Branch Division of Low-Level Waste Management and Decommissioning, NMSS Distribution:

,IlWM/5F.

SWastler JJSurrreier NMSS r/f HTokar MBell LLTB r/f BJagannath PLohaus RBangart JGreeves SBilhorn Central File 8806270338 880525 PDR WASTE WM-72 DCD OFC :LLTB

LL.

NAME:BJagannath :MTokar DATE: 5/26/88

(/24;/88 :

  1. A174 0FFICTAL RECORD COPY M4