Monthly Operating Rept for May 1988 for Limerick Generating Station Unit 1
ML20195B818
Person / Time
Site: Limerick 
Issue date: 05/31/1988
From: Alden W, Gropp R
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8806220002
Download: ML20195B818 (6)


Text

_ _ _ _ _. _ _ _._.

A RAGE DAILY UNIT POMER LEVEL DOCKET No. 50 - 352 LNIT LIMERICK UNIT 1 DATE JUNE 15, 1988 COMPANY PHILADELPHIA ELECTRIC COMPANY R. M. GROPP TECHNICAL ASSISTANT LICENSING SECTION NUCLEAR SUPPORT DEPARTMENT TELEPHONE (215) 841-5058 MONTH HAY 1988 DAY AVERAGE DAILY P0HER LEVEL DAY-AVERAGE DAILY P0HER LEVEL t t94E-NET )

1 P94E-NET )

1 876 17 917 2

8 95 18 925 3

932 19 929 0

929 20 930 5

928 21 931 6

930 22 923 7

917 23 923 8

933 24 925 9

929 25 932 10 901 26 935 f

11 950 27 930 12 930 28 928 13 933 29 924 10 914 30 921 15 925 31 917 16 924 I

8806220002 880531

/\\r l(\\

PDR ADOCK 05000352 J

DCD R

OPERATING DATA REPORT 4

4 DOCKET No. 50 - 352 DATE JUNE 15e 1988 COMPLETED BY PHILACELPHIA ELECTRIC COMPANY R. N. GR0PP TECHNICAL ASSISTANT LICENSING SECTION NUCLEAR SUPPORT OEPARTMENT TELEPHONE (215) 841-5058 OPERATING STATUS

1. UNIT NAME: LINERICK UNIT 1 l NOTES UNIT 1 EXPERIENCED NO l

l l

P. REPORTING PERIOD MAY, 1988 l

OUTAGES DURING THE l

l l

3. LICENSED THERMAL PONER(tHT)8 3293 l

MONTH. PONER IS SEING l

l l

4. NAMEPLATE RATING IGROSS ME):

1138 l

ADMINISTRATIVELY LIMITED l

l l

5. DESIGN ELECTRICAL RATING (NET t94E ):

1055 l

DUE TO A FUEL R00 LEAK.

l l

l

6. MAXIMLM DEPENDABLE CAPACITY IGROSS P94E 1 1092 l

l l

l

7. MAXIMUH DEPENDABLE CAPACITY INET P9tE38 1055 l

l

8. IF CHANGES OCCUR IN CAPACITY RATItCS IITEMS NUtBER 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONSI
9. P0HER LEVEL TO NHICH RESTRICTED, IF ANY (NET 794Els 949.5
10. REASONS FOR RESTRICTIONS, IF ANY Power Restricted Due To A Fuel Rod Leak, THIS MONTH YR-TO-DATE CUttJLATIVE
11. HOURS IN REPORTING PERIOD 7M 3.647 20:423
12. NLASER OF HOURS REACTOR NAS CRITICAL 744.0 3,339.3 16,207.3
13. REACTOR RESERVE SHUTDom HOURS 0.0 0.0 0.0 l

l

14. HOURS GEN',RATOR ON-LINE 7%.0 3,333.0 15,895.7
15. UNIT RESERVE SHUTDom HOURS 0.0 0.0 0.0 i
16. GROSS THERhAL ENERGY GENERATED (PNH )

2,199,938 10,277,602 49,173,983

17. GROSS ELECTRICAL ENERGY GENERATED (t94H) 714.640 3:322.870 16.022:280
18. NET ELECTRICAL ENERGY GENERATED lt94H) 687.262 3.198.886 15.366.723 PAGE 1 0F 2 I

l

OPERATING DATA REPORT ICONTINUED)

DOCKET No. 50. M' DATE JUNE 15, 1988 THIS NONTH YR-Tr 9 ATE CUMULATIVE

19. UNIT SERVICE FACTOR 100.0 91.4 77.8 2D. UNIT AVAILABILITY FACTOR 100.0 91.4 77.8
21. UNIT CAPACITY FACTOR (USING MDC NET) 87.6 83.1 71.3
22. UNIT CAPACITY FACTOR IUSING DER NET) 87.6 83.1 71.3
23. UNIT FORCED OUTAGE RATE 0.0 8.6 4.8
24. $$1UTDOH43 SCHEDULED OVER NEXT 6 NONTHS (TYPE, DATE, AND DURATION OF EACH)*
25. IF SHUTD044 AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUPt
26. UNITS IN TEST STATUS (PRIOR TO C0tt1ERCIAL OPERATION)I FORECAST ACHIEVED INITIAL CRITICALITY 12/19/84 12/22/84 IMITIAL ELECTRICITY MID APRIL 85 4/13/85 COtt1ERCIAL OPERATION IST QTR 86 2/01/86 PAGE 2 0F 2

r __ - - - _ _ - - _ -

'liUTDC4G AND P0HER REDUCTIONS DCC4ET NO. 50 - 352 UNIT NAME LIHERICK UNIT 1 DATE.ANE 15,1908 REPORT MONTH MAY, 1988 CONPLETED BY PHILADELPHIA ELECTRIC COMPANY R. H. GROPP TECHNICAL ASfdSTANT LICENSING SECTION NUCLEAR SUPPORT DEPARTMENT TELEPHONE I2151 841-5058 s..........................................................................................................................

l-1 I

l l METHOD OF l LICENSEE lSYSTEHlCOHPONENT! CAUSE AND CORRECTIVE I

l TY PE l DUR ATION l RE ASON I SHUTTI NG D06fi l EVENT l CODE I CODE l ACTION TO C. I DATE I (111 (HOURS)l (2) l RE ACTOR ( 3 ) l REPORT 8 l (4) l (5) l PREVENT RECURRENCE l

l 1 ----- 1 I

I I

I I

I I

I I

I l

l I

I (1)

It)

(3)

(4)

? - FORCED REASON NETHOD EXHIBIT G - INSTRUCTIONS 1 - SCHEDULED A. EQUIPMENT FAILURE (EXPLAIN) 1 - MANUAL FOR PREPARATION OF DATA B - HAINTENANCE OR TEST 2 - MANUAL SCRAM.

ENTRY SHEETS FOR LICENSEE C - REFUELING 3 - AUTOMATIC SCRAM.

EVENT REPORT (LER)

D - REGULATORY RESTRICTIDH 4

OTHER (EXPLAIN)

FILE INUREG-0161)

E - OPERATOR TRAINING + LICENSE EXAMINATION F - ADMINISTRATIVE (5)

G - OPERATIONAL ERROR (EXPLAIN)

H - OTHERIEXPLAIN)

EXHIBIT I - SAME SOURCE

Docket.No. 50-352

. ~

Attachmsnt to Monthly Op3 rating Raport for

~ ~..

May, 1988 Limerick Generating Station Unit 1 May 1 through May 31, 1988

'I..

Narrative Summary of Operating Experiences The unit began the report period operating at approximately 85% power.

On May 3, 1988, 90% reactor power was achieved and was limited due to concerns about a fuel leak.

On May 7, 1988, a Reactor Protection System (RPS) half-scram signal and various-Nuclear Steam Supply Shutoff (NSSSS) isolations occurred due to the failure of a 60 amp fuse.

Recirculation Pump temperature increased as a result of the isolation of the Drywell Chilled Water and Reactor Enclosure Cooling Water systems.

Reactor power was reduced to 80%

until normal cooling could be restored.

The fuse was replaced, the isolations reset, and the plant systems were returned to normal.

The unit ended the report period operating at approximately 90% power limited by the fuel leak concern.

II. Challenges to Main Steam Safety Relief Valves There were no challenges to the Main Steam Relief valves during the month of May.

t l

l l

i

t

+

PHILADELPHIA ELECTRIC COMPANY 2301 MARKET STREET P.O. BOX 8699 PHILADELPHI A. PA 19101 caisi e4i.4ooo June 15, 1988 Docket No. 50-352 Director Office of Resource Management U.S.

Nuclear Regulatory Commission Washington, DC 20555 Attention:

Document Control Desk

SUBJECT:

Limerick Generating Station Monthly Operating Report Gentlemen:

Enclosed is the monthly operating report for Limerick Unit 1 for the month of May, 1988, forwarded pursuant to Technical Specification 6.9.1.6.

Very truly yours,

/W W. M. Alden Director Licensing Section Nuclear. Support Division.