r,
]
'o UNITED STATES 4
+
g NUCLEAR REGULATORY COMMISSION o
h WASHINGTON, D. C. 20555
~s...../
May 27, 1986 Docket No. 99901044/86-01 Standard Environmental Products ATTN: Mr. Pat Livecchi President Post Office Box 866 Cherry Hill, New Jersey 08003 Gentlemen:
This refers to the inspection conducted by Mr. Jeff Jacobson of this off' ice on March 17-19, 1986, of your facility at Cherry Hill, New Jersey and to the discussions of our findings with you at the conclusion of the inspection.
This inspection was made'as a result of an allegation received concerning improper certification of equipment to environmental qualification standards.
This allegation was found to be unsubstantiated. Areas examined during the inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.
During the inspection it was found that the implementation of your QA program failed to meet certain NRC requirements and that Standard Environmental Products had not developed procedures as required by 10 CFR Part 21. The specific findings and references to the pertinent requirements are identified in the enclosures to this letter.
The enclosed Notice of Violation is sent to you pursuant to the provisions of Section 206 of the Energy Reorganization Act of 1974. You are required to submit to this office within 30 days from the date of this letter a written statement containing:
(1) a description of steps that have been or will be taken to correct these items; (2) a description of steps that have been or will be taken to prevent recurrence; and (3) the dates your corrective actions and preventive measures were or will be completed.
Consideration may be given to extending your response time for good cause shown.
You are also requested to submit a similar written statement for each item which appears in the enclosed Notice of Nonconformance.
The responses requested by this letter are not subject to the clearance procedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.
I 8605290485 860527 PDR GA999 EMV*****
99901044 PDR
r Standard Environmental Products May 27, 1986 In accordance with 10 CFR 2.790 of the Comission's regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public
, Document Room.
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely, ge
.%9 ' !
ary M e.
- ef Vendor Program Branch Division of Quality Assurance, Vendor, and Technical Training Center Programs Office of Inspection and Enforcement
Enclosures:
1.
Appendix A-Notice of Violation 2.
Appendix B-Notice of Nonconformance 3.
Appendix C-Inspection Report 99901044/86-01 4.
Appendix D-Inspection Data Sheets (1 page)
.