- _ _ _ _ _ _
l imumm mm mmm mm m mmmm mmmmmm=== mmm-A mmmmMmmm mm===MmmmmmMM MMmpI l
U.S. NUCLEAR RE!ULATGY COMMISSl*.N MacFonM41s I
=
CERTIFICATE CF COMPLIANCE E
io cra "
FOR RADl! ACTIVE MATERIALS PACKA"f ES t a CERTiFtCATE NUMBER b REVI5 ion NUMBER c PACKAGE IDENYifiCAlloN NUMBER d PAGE NUMBER
- e. TOTAL NUMBER PAGES 9205 0
USA /9205/B(U) 1 2
2 PREAMBLE
[
- e. This certificate is issued to certif y that the packaging and contents described in item 5 below, meets the applicable safety standards set forth in Title 10 Code l
of Federal Regulations. Part 71,' Packaging and Transportation of Radioactive Material."
b Th.s certificate does not reheve tne consignor from compliance with any requirement of the regulations of the U S Department of Transportation or other applicable regulatory agencees, encivding the government of any country through or into which the package will be transported 6
E
- '"sEZo^15 ,*Bf * '"' *** ' ^ **" ^"^"S ", 'f?"E ANJi!E5"C$o 'M&oR*"o'fA,70* cation l
^
^
e t
Teledyne Energy Systems Teledyne Energy Systems application dated N
110 West Timonium Road October 16, 1985, as supplemented.
h l
Timonium, MD 21093 c OOCKET NUMBER a CONOiTIONS This certifecate is conditional upon fulfilling the requirements of 10 CFR Part 7 t, as applicable, and the conditions specified below g
(a) Packaging l
5 l
(1) flodel No.:
SENTINEL SS j
(2) Description E
g j
The packaging contains a thermoelectric generator with 32,900 ci of strontium 90 fluoride meeting the requirements of special fonn radio-2 active material.
i E
The double encapsulated fuel is held in,ide a depleted uranium biological N
shield (7.3-inch OD x.8.85-inch) which is provided with a stepped plug g
lid and secured with 6,1/4-inch x 1.25-inch long steel bolts.
The depleted uranium shield is held in position within the generator's aluminum housing by sized Min-K thermal insulation. A retaining ring g
is used to preload the Min-K and to dampen any vibrational loads.
g E
During shipment, the finned aluminum housing of the thermoelectric
(@
generator is contained within an inner shipping container which is provided with stepped lid and secured with 12, 3/4-inch steel bolts
('
which are recessed. flovement of the generator is restricted by an RTG Preload Assembly within the, inner vessel.
The inner container is constructed of ASTM A-181 forged steel and a lid fabricated of A-36
[
s teel.
The inner container dimensions are 26.1-inch ID x 21.7-inch H
c high x 36.53-inch OD x 32.2-inch high plus 2-inch thick aluminum h
bumper pad (spacer) located on the top lid.
[
The outer shipping container is fabricated from 3/8-inch thick 304L l
stainless steel (SS) with a 3/4-inch thick bottom plate. The top lid is joined to the bottom of the outer container by 12, 3/4-inch steel bolts and nuts through 2, 3/4-inch thick SS flanges. The closure flanges are gasketed to preclude entry of rain water. The outer l
package is reinforced by 4, 3/8-inch thick SS stiffener ribs (external).
l The lid stiffener ribs contain 4, 2-1/8-inch diameter lifting / tie-down p
holes. The bottom plate is welded to 2, 4-inch I-beams.
The gross weight of the package is 8,460 pounds which includes the N
276-pound weight of the thennoelectric generator.
8605290161 860523 PDR ADOCK 07109205
-======iC______
==============
I rinmurianenraritimmaramurstefamesLMMan!1gnamurJgs;istTampsrasarmen'usexwhim i
CONom0N$ (contrued) i Page 2 - Certificate No. 9205 - Revision fio. 0 - Docket No. 71-9205 y
l t
I il l
S.
(a)
(3) Drawings l
The packaging is constructed in accordance with Teledyne Energy Systens f
i Fi g u res 1.1, i. l a, 1. l b, 1. l c, 1.2, 1. 3a, 1. 3b, 1. 3c, 1.3d, 1. 3e,
g l
1.4a, 1.4b, 1.5, 1. 7a, 1. 7b, 1. 7c, l.Ba, 1. 3b, 1. 8c, 1.9a, 1. 9b, 1.9c,
p I
a nd 1.9d.
F 1
jkl I
(b) Contents N
d ti l
(1) Type and fom of naterial f
I 1
Strontium fluoride (90SrF l doubly encapsulated in Hastelloy C-276 f
I l
which meets the requ emktstof-sgecial form radioactive material.
l (2) tiaximo quantity. df matertal per package -
f.
I l
32,900 curies.
M i
it i
6.
In addition to the requirenents of Subpart G of 10 CFR Part< 71, each pactage l
must meet the Acceptance Tests and t'.aintenance Progrart of Section 8.0 of the lgl application.
s g
l l 1 7.
The package authorized by this certificate is'hereby approvedifor use under the g
i $
general license provisions of 10 CFR Jt71.12,
~
l 4 I l 8.
Expiration date: ffay 31, 1991.
l REFEREtlCES l
1 Teledyne Energy Systens application dated October 16, 1985.
4, t
l' h) l Supplements dated:
February 24 and May 7,1986, i
E l
FOR THE 11.S.. NUCLEAR REAOLATORY COMtf!SSION y
i p
l h
h d
kv Charles E. itacDonald, Chief l
4 Transporta tion Certification Branch y
Divisten of Fuel Cycle and q
Material Safety, VtSS 4
t V
' l Date:
MAY 2 31ong D
1 b
I r
i l
l,
il I
't l
r i
l I
I l-,
,I--uss-mem.-umwr
.mm gJ I