ML20170A803
| ML20170A803 | |
| Person / Time | |
|---|---|
| Site: | 07201015 |
| Issue date: | 06/25/2020 |
| From: | Bernie White Storage and Transportation Licensing Branch |
| To: | Fowler W NAC International |
| BHWhite NMSS/DFM/STL 415.6577 | |
| Shared Package | |
| ML20170A800 | List: |
| References | |
| EPID L-2019-LLA-0291 | |
| Download: ML20170A803 (2) | |
Text
.
June 25, 2020 Mr. Wren Fowler Director, Licensing NAC International 3930 East Jones Bridge Road, Suite 200 Norcross, GA 30092
SUBJECT:
APPLICATION FOR AMENDMENT NO. 8 TO THE MODEL NO. NAC-UMS STORAGE CASK - REQUEST FOR ADDITIONAL INFORMATION
Dear Mr. Fowler:
By letter dated December 18, 2019 (Agencywide Documents Access and Management System
[ADAMS] Package Accession No. ML20006D749), as supplemented on April 24, 2020 (ADAMS Package Accession No. ML20122A201, NAC International (NAC) submitted an application for Amendment No. 8 to the Model No. NAC-UMS storage cask. The application proposes to add damaged boiling-water reactor spent fuel, drawing changes, and the addition of low burnup, undamaged 10x10 fuel assemblies, and high burnup damaged and undamaged 8x8, 9x9, and 10x10 fuel assemblies.
In connection with our review, we need the information identified in the enclosure to this letter.
The request for additional information (RAI) requested in this letter should be submitted in the form of revised safety analysis report pages. Please provide your response within 2 months from the date of this letter.
Please reference Docket No. 72-1015 and Enterprise Project Identifier (EPID) No.
L-2019-LLA-0291 in future correspondence related to this request. The staff is available to meet to discuss your proposed responses. If you have any questions, I may be contacted at (301) 415-6577.
Sincerely, Bernard H. White IV, Senior Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 72-1015 EPID No. L-2019-LLA-0291
Enclosure:
RAI Bernard H. White Digitally signed by Bernard H.
White Date: 2020.06.26 12:46:29 -04'00'
- via email OFFICE DFM DFM DFM DFM NAME BWhite WWheatley*
DTang*
Asotomayor-Rivera*
DATE 6/4/2020 6/18/2020 6/5/2020 6/17/2020 OFFICE DFM DFM DFM NAME RChang*
TBoyce*
JMcKirgan*
DATE 6/22/2020 6/22/2020 6/25/2020