ML20164A085
ML20164A085 | |
Person / Time | |
---|---|
Site: | Limerick ![]() |
Issue date: | 06/03/2020 |
From: | Kerr J Dresser |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
ATS 808 | |
Download: ML20164A085 (12) | |
Text
Dresser LLC 12970 Normandy Blvd Jacksonville, Florida 32221 Baker Hughes ~
10 CFR PART 21 COMMUNICATION Dresser CAR: ATS 808 Date: June 3, 2020 To: Document Control Desk US Nuclear Regulatory Commission Washington DC 20555-0001
Subject:
10 CFR Part 21 Report for Dresser LLC (Masoneilan) Valves with Screwed Baffle Design
__ ___ _ -===- Reporta_bl~C?~dition [21.21 (d)] ==,,__6_0 Day Interim Report [21.21 (a)(2)] __________ _
--'-'X'---Transfer of Information [21.21 (b)] ___ Safety Information Communication Summary:
On May 14, 2020 the Exelon Limerick Nuclear Generating Station notified Dresser LLC that the baffle, a part of the main plug contained within a Masoneilan Globe Piloted Control Valve had separated from the plug and was found downstream within their water system.
The valve was furnished to Limerick through Bechtel Power Corporation on or about November 21, 1980 from the Masoneilan International, Inc. Company located in Norwood, Massachusetts, as tag number HV-C51-103A, and serial number N00207-8-1.
Discussion with the Limerick Generating Station shows that Limerick procured a replacement plug in 2011 for the valve originally supplied in 1980. The part number of the plug furnished by Masoneilan in 1980 under serial number N00207-8-1 was 011470-887-899, and the part number of the plug furnished by Dresser in 2011 *as the replacement was 011490440-1X3U0000.
The original plug contained within N00207-8-1 had a screwed baffle plate design secured by four torqued and tack welded socket head screws, which was the Masoneilan standard offering until the end of 1980. After 1980 Masoneilan began to do a full 360 tack weld around the baffle screws. This practice continued until about 1987 when Dresser ceased all production of the screwed baffle design and replaced it with an integral design.
Dresser LLC 12970 Normandy Blvd Jacksonville, Florida 32221 From 1987 to present day, any request to Dresser for nuclear replacement parts that originally contained the screwed baffle design are quoted with the part number of the integral design.
While the notification by Limerick of the baffle becoming loose from the main plug on May 14, 2020 was the first such notification that the baffle had become disengaged in a nuclear facility, Dresser wants to make sure that all nuclear utilities are aware of the potential problem and take whatever actions they deem appropriate in accordance with their respective programs.
lssuedbJK A !~£A----
John Kerr Nuclear Quality Leader Dresser LLC 12970 Normandy Blvd Jacksonville, Florida 32221 Attachments: : 10 CFR Part 21 Notification Process 2- Pages : Original NPV-1 Form from Masoneilan International to Bechtel Power Corp 2- Pages Picture 1: Typical picture of Masoneilan screwed baffle design plug 1- Page Picture 2: Typical picture of Masoneilan screwed baffle design plug with tack welding 1-Page Picture 3: Picture from Limerick Station showing baffle design failure 1- Page Picture 4: Picture from Limerick Station showing baffle design failure (different view) 1-Page Picture 5: Cut-away of a Masoneilan 40400 Series Pilot Balanced Valve internal 1-Page Picture 6: Picture of the integral design baffle plug currently provided by Dresser 1- Page (Total pages including this two page Communication: 12- Pages)
Dresser LLC 12970 Normandy Blvd Jacksonville, Florida 32221 Notice: This 10 CFR Part 21 Notification pertains only to the plants or facilities specifically indicated as being affected. Dresser LLC has not considered or evaluated the applicability, if any, of this information to any plants or facilities other than those specifically indicated as being affected and for which Dresser LLC supplied the equipment or services addressed in the Notification.
Determination of applicability of this information to a particular plant of facility, and the decision of whether or not to take action based upon the Notification, are the responsibility of the Owner of that plant or facility.
ATTACHMENT 1 (1) Name and address of the individual or individuals informing the Utility:
John Kerr Nuclear Quality Leader Dresser LLC 12970 Normandy Blvd Jacksonville, Florida 32221 (II) Identification of the facility, the activity, or the basic component supplied for such facility or such activity within the United States which fails to comply or contains* a defect.
Original notification of this issue was made by the Exelon Limerick facility on May14,2020. While the initial notification to Dresser LLC was made specifically to an 8" control valve, model number 38-40411 supplied to the Bechtel Power Corporation in support of the Limerick Generation Station under Serial Number N00207-8-1 as tag number HV-C51-103A, the use of a plug with a screwed in baffle design may be
~applicable to a number of nuclea=r~u=t=ili=ti~es~"*----------------------*---~
(Ill) Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect.
Dresser LLC, formerly identified as Masoneilan, or Dresser Masoneilan, or Masoneilan International, or Masoneilan Division, McGraw-Edison Company.
(IV) Nature of the defect of failure to comply and the safety hazard which is created or could be Created by such defect of failure to comply.
The baffle was originally added due to instability caused during commercial applications in liquid service where the water had a straight line of contact. Due to logistics it was decided to add the baffle onto all pilot plug designs independent upon the service conditions or the application.
Around 1980 it was shown that we had some issues in vapor, gas, steam service where the baffle was coming undone due to vibration. It was determined by Dresser to remove the baffle from all service except for liquid application. If the customer didn't know the service you wouldn't get a baffle. Additionally, in water applications the tack weld around the baffle retaining screws was enhanced to a full 360 weld and the material was standardized to better stainless steel.
. Betw9-en 1980 and 1984 the use of the screwed baffle was still in place. There was one possible case of a missing baffle in water service in June 1984 in a commercial application.
In 1987 it was decided to cease all production of the screwed baffle and go fully to the integral design. After which all the pilot trim design have the integral baffle.
Dresser LLC 12970 Normandy Blvd Jacksonville, Florida 32221 (V) The date on which the information of such defect or failure to comply was obtained.
Initial notification that the baffle furnished as part of the valve main plug, part number 011470-887-899 had become disengaged from the plug was made on May 14,2020 by Limerick to Dresser LLC.
(VI) In the case of a basic component which contains a defect of failures to comply, the number and location of these components in use at, supplied for, being supplied for, or may be supplied for, manufactured, or being manufactured for one or more facilities or activities subject to the regulations in this part.
Because nuclear utilities procure material from each other and through secondary source manufactures, Dresser LLC does not have a definitive list of all utilities with an installed base containing a screwed baffle design, Dresser is providing this information to the Nuclear Regulatory Commission so that they may forward to all US utilities for review and action.
(VII) The corrective action which has been, is being, or will be taken; the name of the individual or
~o~rganiz:ation_r_~Ronsible for the action; and the length of time that has been or will ta_ke to_ _ _ _ _ __
complete the action.
This Transfer of Information, in accordance with 10CFR Part 21.21 (b) is being communicated to the US Nuclear Regulatory Commission to disseminate to all US Nuclear Facilities to determine the impact on their plant. Each Utility should review their records to determine if they still possess any 40K series plugs without the integral baffle and determine whatever actions are required under their program.
(VIII) Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers of licensees.
Affected plants should perform whatever actions are required under their program. A review of any potential release of foreign material should be conducted.
(IX) In the case of an early site permit, the entities to whom an early site permit was transferred.
This is not an early site permit.
, PAGE / OF~
FORM NPV-1 N _CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*
. As Requited by the Provisions of the ASME Code, Section Ill, Div. 1
- 1. Manufactured by Masoneilan International, Inc., 63 Nahatan St., Norwood, .MA 02062 (Name and Address of N Citrtifica1.e Hold~rl * *
- 2. Manufactured for Bechtel Paver Corp., .1:-'.0. Box 3~o5, San Francisco CA 94119
- T .!~~ an'1 Ad-dresM_t P~asers3L9wr>erh Uni ts 1 2 Philadelphia PA
- 3. Location of Installation ~*a=..J.CK l.:i!Il a g i:auo , & ,
(Name end AgdressL 8
- 4. Pump or Valve _ _ Globe
___ _ _ _ _Valve ControJ. _ _ _ _ . Nominal Inlet Size _ _ _ 8"_ _ _ Outlet Size --....,.,...--,-,--
(inch) (inch)
(al Mod.el No.. (bl N Certificate Holder's (cl Canadian Series No. Serial Registration (di Drawing (f) Nat'I. (g) Year or Type No. No. No. (el Class Bd. No. Built (1) 38-40411 N00207-8-l N/A A9100 2 N/A 1980 (2)
(3)
(4)
IS)
(6) 17)
(8)
(9)
(10)
P.O. 803l-M-250A-AC Water Tag No. HV-C51-103A
- 5. ' (Brief description of service for whieh equipment wH designed)
* - -5;-Oesigo-Condition*s*-- ------ 485 -----* *ps,--- ---A 80- --- ----- -*F or Valve PressureClass ----N/A (1)
(Pressure) {Temperature)
- 7. Cold Working Pressure llOO psi at 100°F.
B. Pressure Retaining Pieces Mark No. Material Spec. No. Manufacturer Remarks la) Castings F-7679-3 .ASME SA 216 l:iH. wus Quaker Alloy Body F-7787-3 AS.ME SA 216 GR WCB Quaker Alloy Bonnet lb) Forgings N/A
,,cll"'\\.1.t
)"": ~ \,
(1) For manually operated valves only.
- Supplemental sheets in form of lists, sketches or drawings may be used .provided {1 I size is 8-1/2" x 11*. 12) information in
\
- . \
- l items 1, 2 and 5 on this Data Report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at top of this form.
This form (E00037) may be obtained from the Order Dept., ASME, 345 E.47th St., New York, N.Y. 10017
\
FORM NPV-1 (Back)
Mark No. Material Spec. No. Manufacturer Ri::marks ,.
{cl Bolting C:!!'::!Qi;lc;q ':\ ASME SA 193 GR B7 ,
Texas Bolt Ccmoanv Stud Co::ie AS84 ..
6024521 I ASME SA 194 GR 2H Texas Bolt Ccmpany Nut Code JD2 I I
I (d) Other Parts 4157-1 I ASME SA 351 GR CFBM Quaker Alloy P.Lug 4194-3 ASME SA 351 GR CFBM Quaker Alloy Pilot
- 9. Hydrostatic test 112 5 psi Disk Differential test pressure 14 3 psi.
CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump, or valve, conforms to the rules ol construction of the ASME -code for Nuclear Power-Planf Co/J\:onents. -Section Ill, -Div. I., ~ition --
197 ?- - , -
Addenda N/A , Code Case No. N ~ - ,P~- NA Signed Masonefi~ International, Inc. by ~~ 11 /21/2ci (N Cer1ific.ite Holder) N-lB 36 N 8/19/83 Our ASME Certificate of Authorization No. _ _ _ _ _ _ _ to use the _ _ _ _ _ _ _ symbol expires CERTIFICATION OF DESIGN Masoneilan International, Inc.
Design information on file a t - - - - - - - - . . . . . , . . - , , . . - - - - - - - - - - - - - - - - - - - - - - - - -
Stress analysis report (Class ronly) on file at _ _l_1/_A __________________________
Design specifications certified by (1)
Gilbert
---cs=--~ H. Brittain
~~ - - - - - - - - - - - - - - - - - - - - - - - - - -
26 PE State CA Reg. No =----------
Stress analysis cen)fied by (1) _ _N...:7_A __-.-.--=----------------------------c:!11To,jl"'
PE State N;A Reg. No. _ _N_A _ _ __
(1) Signature not reQuired. List name only.
CERTIFICATE OF SHOP INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors andtheStateorProvinceof Mass. andemployedby H.S.B.I. & I. Co.
of Hartford, CT have inspected the pump, or valve. described in this Data Report on a c~ '3 0 19 ~ , and state thatto the best of my knowledge and belief, the N Certificate Holder has con-structed this pump, or valve, in accordance with the ASME Code, Section Ill.
By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions ~ f 71 PA lvC 2.J>f 6, (Nan Bd., State. Prov. and No.)
i
,I
40400Sert
- PIiot Balanced Figures