ML20161A171

From kanterella
Jump to navigation Jump to search
Final ASP Analysis - Vogtle 1 (LER 424-87-036)
ML20161A171
Person / Time
Site: Vogtle 
Issue date: 06/09/2020
From: Christopher Hunter
NRC/RES/DRA/PRB
To:
Littlejohn J (301) 415-0428
References
LER 1987-036-00
Download: ML20161A171 (4)


Text

B-165 PRECURSOR DESCRIPTION SHEET LER No.:

424/87-036 Event

Description:

Auxiliary feedwater system is inoperable twice Date of Event:

6/3/87 and 6/15/87 Plant:

Vogtle Unit I

-EVENT DESCRIPTION Sequence Plant personnel disabled the auxiliary feedwater valve actuation circuitry by pulling incorrect fuses.

Personnel incorrectly used and interpreted a procedure during MFW pump maintenance during which it was intended to only block auto AFW initiation on MFW pump trip.

This occurred twice. On 6/3/87 the AFW system was inoperable for -49 h and on 6/15/87 the AFW system was inoperable for -11 h.

Corrective Action The fuses were replaced, the procedure was corrected, and personnel were instructed on the importance of performing a detailed review of system clearances and the importance of procedure compliance as well as correct procedure interpretation.

Plant/Event Data Systems Involved:

Auxiliary feedwater system Components and Failure Modes Involved:

AFW unavailable Component Unavailability Duration:

49 h and 11 h Plant Operating Mode:

3 (0% power)

Discovery Method:

Operator observation Reactor Age:

0.3 y Plant Type:

PWR Comment~s None.

MODELING CONSIDERATION AND DECISIONS Initiators Modeled and Initiator Nonrecovery Estimate Postulated LOOP, Base case nonrecovery

LOCA, transient Event Identifier:

424/87-036

B-166 Branches Impacted and Branch Nonrecovery Estimate AFW 0.34 Recoverable locally AFW/Emergency 0.34 Recoverable locally Power Plant Models Utilized PWR plant Class B Event Identifier:

424/87-036

B-167 CONDITIONAL CORE DAMAGE PROBABILITY CALCULATIONS Event Identifier:

424/87-036 Event

Description:

Auxiliary feedwater system is inoperable twice Event Date:

06/03/87 Plant:

Vogtle 1 UNAVAILABILITY, DURATION= 60 NON-RECOVERABLE INITIATING EVENT PROBABILITIES TRANS LOOP LOCA SEQUENCE CONDITIONAL PROBABILITY SUMS End State/Initiator 2. 9E-02 I.IE-04 6.2E-05 Probability CD CV TRANS LOOP LOCA Total TRANS LOOP LOCA Total 5.4E-06 8.8E-07 5.8E-10 6.3E-06 9.2E-06

( 4.9E-l0 5.4E-07 9.7E-06 ATWS TRANS LOOP LOCA Total o.OE+O0

0. OE+00
0. OE+00 0.OE+00 SEQUENCE CONDITIONAL PROBABILITIES (PROBABILITY ORDER)

Sequence 126 trans -rt AFW mfw hpi(f/b) -ss.depress cond/mfw 120 trans -rt AFW mfw -hpi(f/b) -hpr/-hpi porv.open -ss.depress cond/mfw 212 loop -rt/loop

-emerg.power AFW hpi(f/b) 210 loop -rt/loop

-emerg.power AFW -hpi(f/b) -hpr/-hpi porv.open 127 trans -rt AFW mfw hpi(f/b) ss.depress 121 trans -rt AFW mfw -hpi(f/b) -hpr/-hpi porv.open ss.depress 123 trans -rt AFW mfw -hpi(f/b) hpr/-hpi -ss.depress cond/mfw 125 trans -rt AFW mfw hpi(f/b) -ss.depress -cond/mfw 119 trans -rt AFW mfw -hpi(f/b) -hpr/-hpi porv.open -ss.depress cond/mfw 316 loca -rt AFW mfw -hpi -hpr/-hpi -ss.depress cond/mfw 122 trans -rt AFW mfw -hpi(f/b) hpr/-hpi -ss.depress -cond/mfw End State CD CD CD CD CD CD CD CV CV CV CV Prob 2.4E-06 2.2E-06 4.0E-07 3.7E-07 2.6E-07

2. 5E-07
2. 5E-07
4. 5E-06 4.2E-06
4. 8E-07 4.7E-07 N Rec**
3. 3E-02 3.9E-02 1.1E-01 1.3E-01
9. 7E-02 1.2E-01
3. 9E-02
6. 4E-02 7.6E-02
1. 7E-02
7. 6E-02
    • non-recovery credit for edited case SEQUENCE CONDITIONAL PROBABILITIES (SEQU ENCE ORDER)

Sequence End State 119 trans -rt AFW mfw -hpi(f/b) -hpr/-hpi porv.open -ss.depress -

CV cond/mfw Prob N Rec*

4.2E-06 7.6E-02 Event Identifier:

424/87-036

B-168 120 trans -rt AFW mfw -hpi(f/b) -hpr/-hpi porv.open -ss.depress cond/mfw 121 trans -rt AFW mfw -hpi(f/b) -hpr/-hpi porv.open ss.depress 122 trans -rt AFW mfw -hpi(f/b) hpr/-hpi -ss.depress -cond/mfw 123 trans -rt AFW mfw -hpi(f/b) hpr/-hpi -ss.depress cond/mfw 125 trans -rt AFW mfw hpi(f/b) -ss.depress -cond/mfw 126 trans -rt AFW mfw hpi(f/b) -ss.depress cond/mfw 127 trans -rt AFW mfw hpi(f/b) ss.depress 210 loop -rt/loop -emerg.power AFW -hpi(f/b) -hpr/-hpi porv.open 212 loop -rt/loop -emerg.power AFW hpi(f/b) 316 loca -rt AFW mfw -hpi -hpr/-hpi -ss.depress cond/mfw

  • non-recovery credit for edited case CD CD Cv CD CV CD CD CD CD Cv 2.2E-06 3.9E-02 2.5E-07
4. 7E-07 2.5E-07 4.5E-06 2.4E-06 2.6E-07 3.7E-07 4.OE-07 4.8E-07 1.2E-01 7.6E-02
3. 9E-02
6. 4E-02 3.3E-02 9.7E-02
1. 3E-01 I.1E-01 1.7E-02 Note:

For unavailabilities, conditional probability values are differential values which reflect the added risk due to failures associated with an event.

Parenthetical values indicate a reduction in risk compared to a similar period without the existing failures.

SEQUENCE MODEL:

BRANCH MODEL:

PROBABILITY FILE:

c:\\asp\\newmodel\\pwrbnew.cmp c:\\asp\\newmodel\\vogtle.new c:\\asp\\newmodel\\pwrbnew.pro No Recovery Limit BRANCH FREQUENCIES/PROBABILITIES Branch System Non-Recov Opr Fail trans loop loca rt rt/loop emerg.power ep.rec AFW Branch Model:

l.OF.3+ser Train 1 Cond Prob:

Train 2 Cond Prob:

Train 3 Cond Prob:

Serial Component Prob:

AFW/EMERG.POWER Branch Model:

I.OF.l Train 1 Cond Prob:

mfw porv.or.srv.chall porv.or.srv.reseat porv.or.srv.reseat/emerg.power ss.releas.term hpi hpi(f/b) hpr/-hpi porv.open ss.depress cond/mfw lpi/hpi lpr/-hpi.hpr lpr/hpi 4.BE-04 4.6E-06 2.4E-06

2. SE-04 O.OE+00 2.9E-03 I.OE+00 3.8E-04 > 1.OE+00 2.OE-02 > Unavailable 1.OE-01 > Unavailable 5.OE-02 > Unavailable 2.8E-04 5.OE-02 > 1.OE+00 5.OE-02 > Unavailable 2.0E-01 4.OE-02 2.OE-02 2.OE-02 1.5E-02 1.OE-03 1.OE-03 1.5E-04 1.OE-02 3.6E-02 1.OE+O0 1.5E-04 6.7E-01 1.5E-04 1.OE+00 3.9E-01 4.3E-01 1.2E-01 1.OE+00 8.OE-01 1.7E-01 2.6E-01 > 3.4E-01 3.4E-01 3.4E-01 1.OE+00 1.IE-02 1.OE+00 3.4E-01 8.4E-01 8.4E-01 1.OE+00 1.OE+00 1.0E+00 3.4E-01 3.4E-01 1.OE+00 1.OE+00 1.OE-02 1.OE-03 4.OE-04 1.OE-02 branch model file
    • forced Minarick 05-16-1989 07:02:46 Event Identifier:

424/87-036