ML20156A399

From kanterella
Jump to navigation Jump to search

"Draft Meeting" is not in the list (Request, Draft Request, Supplement, Acceptance Review, Meeting, Withholding Request, Withholding Request Acceptance, RAI, Draft RAI, Draft Response to RAI, ...) of allowed values for the "Project stage" property.

COL Docs - Pre-submittal Meeting Draft, VEGP LAR 20-005, Vacuum Relief Valve Technical Specification Changes
ML20156A399
Person / Time
Site: Vogtle  Southern Nuclear icon.png
Issue date: 06/04/2020
From:
NRC
To:
NRC/NRR/DNRL
References
Download: ML20156A399 (34)


Text

From:

Schiller, Alina Sent:

Thursday, June 4, 2020 4:08 PM To:

Vogtle PEmails

Subject:

Pre-submittal meeting draft, VEGP LAR 20-005, Vacuum Relief Valve Technical Specification Changes Attachments:

ND-20-0668_Vacuum Relief (PSM 6-11-20).pdf Attached is a draft LAR that will be discussed during the 6/11/2020 public meeting.

Thanks, Alina Schiller Project Manager Office of Nuclear Reactor Regulation Vogtle Project Office O-13 C10 301-415-8177

Hearing Identifier:

Vogtle_COL_Docs_Public Email Number:

570 Mail Envelope Properties (BL0PR0901MB43242F13A9F621E3D3C0C7EA96890)

Subject:

Pre-submittal meeting draft, VEGP LAR 20-005, Vacuum Relief Valve Technical Specification Changes Sent Date:

6/4/2020 4:07:44 PM Received Date:

6/4/2020 4:07:49 PM From:

Schiller, Alina Created By:

Alina.Schiller@nrc.gov Recipients:

"Vogtle PEmails" <Vogtle.PEmails@nrc.gov>

Tracking Status: None Post Office:

BL0PR0901MB4324.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 247 6/4/2020 4:07:49 PM ND-20-0668_Vacuum Relief (PSM 6-11-20).pdf 1050370 Options Priority:

Normal Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

DRAFT

%+:KLWOH\\

6RXWKHUQ1XFOHDU

'LUHFWRU

2SHUDWLQJ&RPSDQ\\,QF

5HJXODWRU\\$IIDLUV

&RORQQDGH3DUNZD\\

%LUPLQJKDP$/

7HO

-XQH

'RFNHW1RV 

1'





&)5

861XFOHDU5HJXODWRU\\&RPPLVVLRQ

$771'RFXPHQW&RQWURO'HVN

DVKLQJWRQ'&

6RXWKHUQ1XFOHDU2SHUDWLQJ&RPSDQ\\

9RJWOH(OHFWULF*HQHUDWLQJ3ODQW8QLWVDQG

5HTXHVWIRU/LFHQVH$PHQGPHQW

9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV /$5 



/DGLHVDQG*HQWOHPHQ



3XUVXDQWWR&)5 F DQGLQDFFRUGDQFHZLWK&)56RXWKHUQ1XFOHDU2SHUDWLQJ

&RPSDQ\\ 61& UHTXHVWVDQDPHQGPHQWWRWKHFRPELQHGOLFHQVHV &2/V IRU9RJWOH(OHFWULF

  • HQHUDWLQJ3ODQW 9(*3 8QLWVDQG /LFHQVH1XPEHUV13)DQG13)UHVSHFWLYHO\\ 

7KHUHTXHVWHGDPHQGPHQWSURSRVHVFKDQJHVWR&2/$SSHQGL[$7HFKQLFDO6SHFLILFDWLRQV 76 

7KH OLFHQVH DPHQGPHQW UHTXHVW /$5  SURSRVHV FKDQJHV WR &2/ $SSHQGL[ $ 76

&RQWDLQPHQW,VRODWLRQ9DOYHVDQG769DFXXP5HOLHI9DOYHVWRH[FOXGHWKHYDFXXPUHOLHI

FRQWDLQPHQWLVRODWLRQYDOYHVIURP76/&2DQGDGGUHVVWKHFRQWDLQPHQWLVRODWLRQIXQFWLRQ

RSHUDELOLW\\$FWLRQVDQG6XUYHLOODQFHVLQ76

7KHVHFKDQJHVZHUHSUHYLRXVO\\GLVFXVVHGZLWKWKH15&6WDIIDWWHFKQLFDOH[FKDQJHFRQIHUHQFH

FDOO RQ $SULO   $'$06 $FFHVVLRQ 1XPEHU 0/$  DQG D SXEOLF SUHVXEPLWWDO

FRQIHUHQFHFDOORQ-XQH $'$06$FFHVVLRQ1XPEHU0/ 

(QFORVXUHSURYLGHVWKHGHVFULSWLRQWHFKQLFDOHYDOXDWLRQUHJXODWRU\\HYDOXDWLRQ LQFOXGLQJWKH

6LJQLILFDQW +D]DUGV &RQVLGHUDWLRQ 'HWHUPLQDWLRQ  DQG HQYLURQPHQWDO FRQVLGHUDWLRQV IRU WKH

SURSRVHGFKDQJHV

(QFORVXUH  LGHQWLILHV WKH UHTXHVWHG FKDQJHV DQG SURYLGHV PDUNXSV GHSLFWLQJ WKH UHTXHVWHG

FKDQJHVWRWKH9(*38QLWVDQGOLFHQVLQJEDVLVGRFXPHQWV

(QFORVXUH  SURYLGHV WKH LQIRUPDWLRQRQO\\ FKDQJHV WR WKH 9(*3 8QLWV  DQG  7HFKQLFDO

6SHFLILFDWLRQV%DVHVGRFXPHQW

7KLVOHWWHUFRQWDLQVQRUHJXODWRU\\FRPPLWPHQWV7KLVOHWWHUKDVEHHQUHYLHZHGDQGGHWHUPLQHG

QRWWRFRQWDLQVHFXULW\\UHODWHGLQIRUPDWLRQ

61&UHTXHVWV15&VWDIIUHYLHZDQGDSSURYDORIWKLV/$5QRODWHUWKDQ1RYHPEHUWR

VXSSRUWWKHLQLWLDOSODQWHQWU\\LQWR02'(ZKLFKLVWKH$SSOLFDELOLW\\IRUWKHFRQWDLQPHQWLVRODWLRQ

IXQFWLRQIRUWKHYDFXXPUHOLHIYDOYHV'HOD\\HGDSSURYDORIWKLVOLFHQVHDPHQGPHQWFRXOGSXWWKH

DRAFT 861XFOHDU5HJXODWRU\\&RPPLVVLRQ

1'

3DJHRI

SODQWDWLQFUHDVHGULVNRID76UHTXLUHGVKXWGRZQXSRQGLVFRYHU\\RIDQLQRSHUDEOHYDFXXPUHOLHI

YDOYHFRQWDLQPHQWLVRODWLRQIXQFWLRQ7KHFXUUHQWLQLWLDOHQWU\\LQWR02'(IRU8QLWLVVFKHGXOHG

IRU'HFHPEHU61&H[SHFWVWRLPSOHPHQWWKHSURSRVHGDPHQGPHQWZLWKLQGD\\VRI

DSSURYDORIWKH/$5

,QDFFRUGDQFHZLWK&)561&LVQRWLI\\LQJWKH6WDWHRI*HRUJLDE\\WUDQVPLWWLQJDFRS\\RI

WKLVOHWWHUDQGLWVHQFORVXUHVWRWKHGHVLJQDWHG6WDWH2IILFLDO

6KRXOG\\RXKDYHDQ\\TXHVWLRQVSOHDVHFRQWDFW0V$P\\&KDPEHUODLQDW  

,GHFODUHXQGHUSHQDOW\\RISHUMXU\\WKDWWKHIRUHJRLQJLVWUXHDQGFRUUHFW([HFXWHGRQWKHWKRI

-XQH

5HVSHFWIXOO\\VXEPLWWHG

BBBBBBBBBBBBBBBBBBBBBBB

%ULDQ+:KLWOH\\

'LUHFWRU5HJXODWRU\\$IIDLUV

6RXWKHUQ1XFOHDU2SHUDWLQJ&RPSDQ\\

(QFORVXUHV

  9RJWOH(OHFWULF*HQHUDWLQJ3ODQW 9(*3 8QLWVDQG+/-5HTXHVWIRU/LFHQVH

$PHQGPHQW  9DFXXP 5HOLHI 9DOYH 7HFKQLFDO 6SHFLILFDWLRQ &KDQJHV

/$5 



  9RJWOH(OHFWULF*HQHUDWLQJ3ODQW 9(*3 8QLWVDQG+/-3URSRVHG&KDQJHV

WR/LFHQVLQJ%DVLV'RFXPHQWV /$5 



  9RJWOH(OHFWULF*HQHUDWLQJ3ODQW 9(*3 8QLWVDQG+/-&RQIRUPLQJ&KDQJHV

WRWKH7HFKQLFDO6SHFLILFDWLRQV%DVHV )RU,QIRUPDWLRQ2QO\\  /$5 





DRAFT 861XFOHDU5HJXODWRU\\&RPPLVVLRQ

1'

3DJHRI

FF



^^$&7,2172&203/(7(/,67``

DRAFT 6RXWKHUQ1XFOHDU2SHUDWLQJ&RPSDQ\\





1'

(QFORVXUH





9RJWOH(OHFWULF*HQHUDWLQJ3ODQW 9(*3 8QLWVDQG



5HTXHVWIRU/LFHQVH$PHQGPHQW

9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

(QFORVXUHFRQVLVWVRISDJHVLQFOXGLQJWKLVFRYHUSDJH

DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI



7DEOHRI&RQWHQWV



6800$5<'(6&5,37,21



'(7$,/(''(6&5,37,21



7(&+1,&$/(9$/8$7,21



5(*8/$725<(9$/8$7,21



$SSOLFDEOH5HJXODWRU\\5HTXLUHPHQWV&ULWHULD



3UHFHGHQW



6LJQLILFDQW+D]DUGV&RQVLGHUDWLRQ



&RQFOXVLRQV



(19,5210(17$/&216,'(5$7,216



5()(5(1&(6











DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI

3XUVXDQWWR&)5 F DQGLQDFFRUGDQFHZLWK&)56RXWKHUQ1XFOHDU2SHUDWLQJ

&RPSDQ\\ 61& KHUHE\\UHTXHVWVDQDPHQGPHQWWR&RPELQHG/LFHQVH &2/ 1RV13)DQG

13)IRU9RJWOH(OHFWULF*HQHUDWLQJ3ODQW 9(*3 8QLWVDQGUHVSHFWLYHO\\





6800$5<'(6&5,37,21

7KHSURSRVHGFKDQJHZRXOGUHYLVH&2/$SSHQGL[$76&RQWDLQPHQW,VRODWLRQ9DOYHV

DQG769DFXXP5HOLHI9DOYHVWRH[FOXGHWKHYDFXXPUHOLHIFRQWDLQPHQWLVRODWLRQYDOYHV

IURP 76 /&2  DQG DGGUHVV WKH FRQWDLQPHQW LVRODWLRQ IXQFWLRQ RSHUDELOLW\\ $FWLRQV DQG

6XUYHLOODQFHVLQ76





'(7$,/(''(6&5,37,21

7KHFRQWDLQPHQWDLUILOWUDWLRQV\\VWHP 9)6 GHVFULEHGLQ8)6$56XEVHFWLRQ&RQWDLQPHQW

$LU)LOWUDWLRQ6\\VWHPSURYLGHVWKHVDIHW\\UHODWHGIXQFWLRQRIFRQWDLQPHQWYDFXXPUHOLHI'XULQJ

VRPHDWPRVSKHULFZHDWKHUFRQGLWLRQVLWLVSRVVLEOHIRUWKHSUHVVXUHLQWKHFRQWDLQPHQWYHVVHOWR

GURS VLJQLILFDQWO\\ EHORZ WKH RXWVLGH DWPRVSKHULF SUHVVXUH LI WKH FRQWDLQPHQW SXUJH LVRODWLRQ

YDOYHV DUH QRW RSHQ WR DOORZ IRU SUHVVXUH HTXDOL]DWLRQ LQVLGH DQG RXWVLGH FRQWDLQPHQW  7KH

SXUSRVHRIWKHFRQWDLQPHQWYDFXXPUHOLHIOLQHVLVWRSURWHFWWKHFRQWDLQPHQWYHVVHOIURPGDPDJH

GXH WR D KLJK QHJDWLYH SUHVVXUH HYHQW ORZHU SUHVVXUH LQVLGH FRQWDLQPHQW WKDQ RXWVLGH

FRQWDLQPHQW ,IH[FHVVLYHKLJKQHJDWLYHSUHVVXUHH[LVWVLQVLGHFRQWDLQPHQWWKHFRQWDLQPHQW

YHVVHOYDFXXPUHOLHILVDXWRPDWLFDOO\\DFWXDWHGWRSURWHFWWKHLQWHJULW\\RIWKHFRQWDLQPHQWYHVVHO

7KH YDFXXP UHOLHI OLQHV LQFOXGH WZR LQERDUG DQG WZR RXWERDUG DXWRPDWLF LVRODWLRQ YDOYHV WR

SURYLGHUHGXQGDQWYDOYHVHWVVXFKWKDWIDLOXUHRIRQHYDOYHZLOOQRWSUHYHQWWKHYDFXXPUHOLHI

IXQFWLRQ7KHDXWRPDWLFDFWXDWLRQRIWKHV\\VWHPRSHQVWKHRXWERDUGPRWRURSHUDWHGFRQWDLQPHQW

LVRODWLRQYDOYHV9)63/9$%WRSHUPLWDLUWREHLQWURGXFHGWKURXJKWKHLQERDUGFRQWDLQPHQW

LVRODWLRQ FKHFN YDOYHV 9)63/$%   7KH LVRODWLRQ YDOYHV RSHQ DXWRPDWLFDOO\\ RQ D

&RQWDLQPHQW3UHVVXUH+/-/RZVLJQDORUE\\PDQXDODFWXDWLRQ

7KHFRQWDLQPHQWYDFXXPUHOLHILVRODWLRQYDOYHVDUHDOVRFRQWDLQPHQWLVRODWLRQYDOYHVDQGPXVW

EH FORVHG WR OLPLW UDGLRORJLFDO UHOHDVHV WR WKH DWPRVSKHUH  7KH\\ FORVH RQ WKH VDPH VLJQDOV

FRQWDLQPHQWLVRODWLRQRU&RQWDLQPHQW5DGLDWLRQ+/-+LJK WKDWFORVHWKHFRQWDLQPHQWSXUJHLQOHW

DQGGLVFKDUJHLVRODWLRQYDOYHV7KHYDFXXPUHOLHIYDOYHVSURYLGHDSRVVLEOHUDGLRORJLFDOUHOHDVH

SDWKIURPWKHFRQWDLQPHQWSDUDOOHOWRWKHSXUJHGLVFKDUJHLVRODWLRQYDOYHV7KHVHYDOYHVDUH

FORVHGDWDQ\\WLPHWKDWWKHLQVLGHFRQWDLQPHQWYDOYH 9)63/9 LVQRWFORVHGWROLPLWWKH

PDJQLWXGHDQGGXUDWLRQRIWKHGLVFKDUJHWKDWFDQRFFXU7KHFRQWDLQPHQWYDFXXPUHOLHIYDOYHV

SURYLGHDSRVVLEOHUDGLRORJLFDOUHOHDVHSDWKIURPWKHFRQWDLQPHQWDWDQ\\WLPHWKDWWKHLQVLGH

FRQWDLQPHQWSXUJHGLVFKDUJHLVRODWLRQYDOYH 9)63/9 LVQRWFORVHG

$VQRWHGLQ8)6$56XEVHFWLRQWKHFRQWUROORJLFJLYHVSULRULW\\WRRSHQLQJWKHYDFXXP

UHOLHI YDOYHV RQ QHJDWLYH SUHVVXUH RYHU FORVLQJ WKHP IRU WKH FRQWDLQPHQW LVRODWLRQ IXQFWLRQ

%HFDXVHWKHVHWSRLQWWRRSHQWKHYDOYHVLVDWDQHJDWLYHSUHVVXUHUDGLRORJLFDOPDWHULDOZLOOQRW

EHUHOHDVHGIURPFRQWDLQPHQWEHFDXVHDLUIORZVLQWRWKHFRQWDLQPHQWIURPWKHDWPRVSKHUH,ID

KLJKUDGLDWLRQFRQGLWLRQH[LVWVLQWKHUHDFWRUFRQWDLQPHQWEXLOGLQJWKHYDFXXPUHOLHIYDOYHVZLOO

FORVHDXWRPDWLFDOO\\DVVRRQDVWKHORZFRQWDLQPHQWSUHVVXUHVHWSRLQWLVQRORQJHUH[FHHGHGWKXV

SUHYHQWLQJDSRVVLEOHUDGLRORJLFDOUHOHDVHWRWKHDWPRVSKHUH

DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI

7KH9)6YDFXXPUHOLHIV\\VWHPLVGHVLJQHGWRPLWLJDWHWKHFRQWDLQPHQWH[WHUQDOSUHVVXUHHYHQW

LQ8)6$56XEVHFWLRQ([WHUQDO3UHVVXUH$QDO\\VLV$ORVVRIDOODFSRZHUVRXUFHVGXULQJ

FROGDPELHQWFRQGLWLRQVKDVWKHSRWHQWLDOIRUFUHDWLQJWKHZRUVWFDVHH[WHUQDOSUHVVXUHORDGRQ

WKHFRQWDLQPHQWYHVVHO,WKDVEHHQGHPRQVWUDWHGWKDWWKHSHUIRUPDQFHRIWKHYDFXXPUHOLHI

V\\VWHPLVVXIILFLHQWWRPLWLJDWHWKHPD[LPXPH[SHFWHGH[WHUQDOSUHVVXUHVFHQDULR

&RQWDLQPHQWYDFXXPUHOLHIYDOYHV9)63/9$% FKHFNYDOYHV DQG9)63/9$% PRWRU

RSHUDWHGLVRODWLRQYDOYHV DUHGXDOSXUSRVHYDOYHVSHUIRUPLQJWKHVDIHW\\IXQFWLRQWR23(1LQWKH

HYHQWRIH[FHVVLYHQHJDWLYHSUHVVXUHLQVLGHFRQWDLQPHQWDQGDVDIHW\\IXQFWLRQWR&/26(IRU

FRQWDLQPHQW LVRODWLRQ LQ WKH HYHQW RI SRVLWLYH SUHVVXUH DFFLGHQW FRQGLWLRQV ,Q WKH FDVH RI

9)63/9$%WKHIXQFWLRQVDUHSHUIRUPHGRQDXWRPDWLFHQJLQHHUHGVDIHW\\IHDWXUHDFWXDWLRQ

V\\VWHP (6)$6 VLJQDOVUHTXLUHGE\\7HFKQLFDO6SHFLILFDWLRQ 76 /&2³(QJLQHHUHG6DIHW\\

)HDWXUH$FWXDWLRQ6\\VWHP (6)$6 ,QVWUXPHQWDWLRQ'23(1RQ&RQWDLQPHQW3UHVVXUH/RZ

DQG &/26( RQ &RQWDLQPHQW 5DGLRDFWLYLW\\ +LJK DV ZHOO DV &RQWDLQPHQW,VRODWLRQ VLJQDO

&XUUHQWO\\WKH76UHTXLUHPHQWVIRUWKHYDFXXPUHOLHIYDOYHVIRUWKH23(1IXQFWLRQDUHIRXQGLQ

76/&2³9DFXXP5HOLHI9DOYHV'ZKLOHWKH76UHTXLUHPHQWVIRUWKH&/26(IXQFWLRQDUH

IRXQGLQ76/&2³&RQWDLQPHQW,VRODWLRQ9DOYHV'

,QWKHHYHQWWKDWWKUHHRUPRUH&RQWDLQPHQW5DGLRDFWLYLW\\+LJKGHWHFWRUVDUHLQRSHUDEOHRUWKH

5HTXLUHG$FWLRQVWRE\\SDVVDQGRUWULSRQHRUWZR UHVSHFWLYHO\\ LQRSHUDEOHFKDQQHOVDUHQRW

SHUIRUPHGZLWKLQWKH&RPSOHWLRQ7LPHWKHVSHFLILHGDFWLRQLQ76/&2LVWRGHFODUHWKH

DIIHFWHGLVRODWLRQYDOYH V LQRSHUDEOH7KLVDFWLRQZRXOGUHVXOWLQHQWU\\LQWR76IRULQRSHUDEOH

FRQWDLQPHQWLVRODWLRQYDOYH V UHTXLULQJDFWLRQVWRLVRODWHWKHDIIHFWHGSHQHWUDWLRQIORZSDWK:LWK

WKH YDFXXP UHOLHI IORZ SDWKV LVRODWHG WKH RSHUDWRUV ZRXOG DOVR EH UHTXLUHG WR HQWHU LQWR WKH

76IRULQRSHUDEOHYDFXXPUHOLHIYDOYHVVLQFHWKHLVRODWHGIORZSDWKZRXOGUHQGHUWKHP

LQRSHUDEOH ,Q 76  WKH UHTXLUHG DFWLRQ ZLOG EH WR VKXWGRZQ WR 02'(  DQG RSHQ D

FRQWDLQPHQWDLUIORZSDWKLQFKHVLQGLDPHWHU7KHVHDFWLRQVFRQIOLFWZLWKHDFKRWKHUDVRQH

LVWU\\LQJWRLVRODWHIORZIRUFRQWDLQPHQWLVRODWLRQDQGRQHLVUHTXLULQJDQRSHQFRQWDLQPHQWIORZ

SDWK$GGLWLRQDOO\\WKH$FWLRQVRI/&2WRFORVHDQGGHDFWLYDWHYDOYH V LQWKHSHQHWUDWLRQLQ

WKHHYHQWRILQRSHUDEOHYDFXXPUHOLHIYDOYH V GRQRWDFFRXQWIRUWKHSULRULW\\VDIHW\\IXQFWLRQIRU

WKHYDOYHVWRRSHQIRUYDFXXPUHOLHI

7KHUHIRUHFKDQJHVDUHUHTXLUHGWRWKH76DQG76WRUHPRYHWKLVFRQIOLFWDQGSURYLGH

DSSURSULDWHDFWLRQV

$GGLWLRQDOO\\/&2XVHVYDFXXPUHOLHI³IORZSDWKV'WKDWFDQOHDGWRFRQIXVLRQ7KHWZR

LQERDUGFKHFNYDOYHVDQGWKHWZRRXWERDUGLVRODWLRQYDOYHVDUHFRQQHFWHGE\\DVLQJOHFRQWDLQPHQW

SHQHWUDWLRQ7KHUHIRUHWKHFKDQJHVZLOOUHVXOWLQDGGLWLRQDO/&2FODULILFDWLRQ

'HVFULSWLRQRIWKH$FWLYLW\\

76LVFKDQJHGWRH[FOXGHWKHFRQWDLQPHQWV\\VWHPYDFXXPUHOLHIYDOYHVIURP76/&2

DQGDGGUHVVWKHLURSHUDELOLW\\IRUERWKFRQWDLQPHQWLVRODWLRQDQGFRQWDLQPHQWYDFXXPUHOLHILQ

76

76  LV FKDQJHG WR DGGUHVV WKH WZR RSHUDELOLW\\ IXQFWLRQV RI WKH YDFXXP UHOLHI YDOYHV

RSHUDELOLW\\IRURSHQLQJWRSURYLGHFRQWDLQPHQWYDFXXPUHOLHIDQGRSHUDELOLW\\IRUFORVLQJWRSURYLGH

FRQWDLQPHQWLVRODWLRQ,Q76/&2RSHUDELOLW\\RIWZRYDFXXPUHOLHI³IORZSDWKV'LVFKDQJHG

WRUHTXLULQJRSHUDELOLW\\RIWZRYDFXXPUHOLHIFKHFNYDOYHVDQGWZRYDFXXPUHOLHILVRODWLRQYDOYHV

DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI

1HZ$FWLRQVDUHSURYLGHGWRDGGUHVVLQRSHUDELOLW\\IRUWKHFRQWDLQPHQWLVRODWLRQFORVLQJIXQFWLRQ

IRUERWKWKHYDFXXPUHOLHIFKHFNYDOYHVDQGYDFXXPUHOLHILVRODWLRQYDOYHV1HZ6XUYHLOODQFH

5HTXLUHPHQW 65 DGGVDYHULILFDWLRQWKDWHDFKYDFXXPUHOLHILVRODWLRQYDOYHLVFORVHG

H[FHSWZKHQSHUIRUPLQJLWVYDFXXPUHOLHIIXQFWLRQRUZKHQRSHQIRU6XUYHLOODQFHV65

UHQXPEHUHG DV 65  IORZ SDWK LV FKDQJHG WR YDOYH  65 UHQXPEHUHG 65

 LVUHYLVHGWRYHULI\\WKHYDFXXPUHOLHILVRODWLRQYDOYHVDUHYHULILHGWRDFWXDWHWRERWKRSHQ

DQGFORVHGSRVLWLRQV

 7(&+1,&$/(9$/8$7,21

7KLV FKDQJH DGGUHVVHV D FRQIOLFW EHWZHHQ WKH FXUUHQW /&2  $FWLRQV IRU LQRSHUDEOH

FRQWDLQPHQW LVRODWLRQYDOYHV DQG WKH UHTXLUHPHQW WR PDLQWDLQ RSHUDELOLW\\ RI WKHYDFXXP UHOLHI

IXQFWLRQRIWKHFRQWDLQPHQWYDFXXPUHOLHIYDOYHV,QRSHUDELOLW\\RIHLWKHURQHRUERWKRIWKHLQERDUG

YDFXXPUHOLHIFKHFNYDOYH V RULQRSHUDELOLW\\RIRQHRUERWKRIWKHRXWERDUGYDFXXPUHOLHILVRODWLRQ

YDOYH V  VKRXOG QRW EH VXEMHFW WR WKH VDPH FRQWDLQPHQW LVRODWLRQ UHTXLUHPHQWV SUHVHQWHG LQ

/&2 5HTXLUHG $FWLRQV $ DQG % E\\ FORVXUH DQG GHDFWLYDWLRQ RI YDOYH V  LQ WKH

SHQHWUDWLRQIORZSDWKDVWKLVZRXOGSUHYHQWWKHDXWRPDWLFFDSDELOLW\\WRSHUIRUPWKHDVVRFLDWHG

YDFXXPUHOLHIIXQFWLRQ7KHUHIRUH/&2LVFKDQJHGWRH[FOXGHWKHYDFXXPUHOLHIYDOYHVIURP

/&2DQGDGGUHVVWKHRSHUDELOLW\\IRUWKHFRQWDLQPHQWLVRODWLRQFORVLQJIXQFWLRQRIWKHYDFXXP

UHOLHIYDOYHVLQ76$VDUHVXOW76LVFKDQJHGWRLQFOXGH$FWLRQVIRUYDFXXPUHOLHI

YDOYHVGHFODUHGLQRSHUDEOHIRUFORVLQJ76$FWLRQVDOVRKDYHHGLWRULDOFKDQJHVWRGLVWLQJXLVK

WKHYDFXXPUHOLHIYDOYHVLGHQWLILHGDVLQRSHUDEOHIRURSHQLQJIURP$FWLRQVIRUWKHQHZO\\DGGHG

FORVLQJIXQFWLRQ7KH$FWLRQVIRUYDFXXPUHOLHIYDOYHVLQRSHUDEOHIRUFORVLQJDQGYDFXXPUHOLHI

YDOYHVLQRSHUDEOHIRURSHQLQJDUHGLVFXVVHGLQPRUHGHWDLOEHORZ

/&2LVFKDQJHGIURP³7ZRYDFXXPUHOLHIIORZSDWKVVKDOOEH23(5$%/('WR³7ZRFKHFN

YDOYHV DQG WZR YDFXXP UHOLHI LVRODWLRQ YDOYHV VKDOO EH 23(5$%/('  7KLV FKDQJH SURYLGHV

FODULILFDWLRQRIWKHRSHUDELOLW\\UHTXLUHPHQWVZLWKUHVSHFWWRWKHDFWXDOIORZSDWKFRQILJXUDWLRQDQG

YDOYHRSHUDELOLW\\UHTXLUHPHQWV$VVKRZQLQ8)6$5)LJXUH 6KHHWRI PRWRURSHUDWHG

YDFXXP UHOLHI YDOYHV 9)63/9$ DQG 9)63/9% DUH ORFDWHG LQ LQGHSHQGHQW SDUDOOHO

SDWKVRXWVLGHFRQWDLQPHQW&KHFNYDOYHV9)63/9$DQG9)63/9%DUHORFDWHGLQ

LQGHSHQGHQWSDUDOOHOSDWKVLQVLGHFRQWDLQPHQW7KH\\DUHFRQQHFWHGE\\DFRPPRQFRQWDLQPHQW

SHQHWUDWLRQ$VVXFKIORZSDWKFDQEHDPELJXRXVLQWKDWHLWKHURIWKHPRWRURSHUDWHGYDOYHV

9)63/9$RU9)63/9%RSHQHGDQGRQHRIHLWKHURIWKHFKHFNYDOYHV9)63/9$

RU9)63/9%RSHQHGSURYLGHVDYDFXXPUHOLHIIORZSDWK LHIRXU³IORZSDWKV'FRXOGEH

LGHQWLILHG 7RSURYLGHVLQJOHIDLOXUHYDFXXPUHOLHIFDSDELOLW\\WZRPRWRURSHUDWHGYDOYHV 9)6

3/9$DQG9)63/9% DUHUHTXLUHGWREH23(5$%/(IRURSHQLQJDQGWKHWZRFKHFN

YDOYHV 9)63/$DQG9)63/% DUHUHTXLUHGWREH23(5$%/(IRURSHQLQJ

)RUFRQWDLQPHQWLVRODWLRQRSHUDELOLW\\ERWKFKHFNYDOYHVPXVWEHDEOHWRFORVHDQGERWKPRWRU

RSHUDWHGYDFXXPUHOLHILVRODWLRQYDOYHVPXVWEHDEOHWRFORVHWRSURYLGHVLQJOHIDLOXUHLVRODWLRQ

SURWHFWLRQIRUWKHFRPPRQSHQHWUDWLRQIORZSDWK)RUDVLQJOHEDUULHUIRUFRQWDLQPHQWLVRODWLRQ

HLWKHUERWKWKHFKHFNYDOYHVPXVWEHDEOHWRFORVHRUERWKWKHPRWRURSHUDWHGLVRODWLRQYDOYHV

PXVWEHDEOHWRFORVH 1RWHWKDWYDOYHV9)63/9DQG9)63/9DUHDOVRDVVRFLDWHG

ZLWKWKHVDPHSHQHWUDWLRQIORZSDWKKRZHYHURSHUDELOLW\\IRUWKHVHYDOYHVUHPDLQDGGUHVVHGE\\

76,QRSHUDELOLW\\RIWKHVHYDOYHVFRXOGLPSRVH76$FWLRQVRQWKHFRQWDLQPHQWYDFXXP

UHOLHIYDOYHV7KHVHUHTXLUHPHQWVDUHQRWLPSDFWHGE\\WKHSURSRVHGFKDQJHV 7KHUHIRUHWZR

DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI

YDFXXPUHOLHIFKHFNYDOYHVDQGWZRYDFXXPUHOLHILVRODWLRQYDOYHVDUHUHTXLUHGWREH23(5$%/(

IRUFORVLQJ

7R EH FRQVLGHUHG 23(5$%/( IRU RSHQLQJ D YDFXXP UHOLHI FKHFN YDOYH PXVW EH FDSDEOH RI

RSHQLQJ RQ D GLIIHUHQWLDO SUHVVXUH RI OHVV WKDQ RU HTXDO WR  SVL RXWVLGH DWPRVSKHUHWR

FRQWDLQPHQWSUHVVXUH7REHFRQVLGHUHG23(5$%/(IRUFORVLQJDYDFXXPUHOLHIFKHFNYDOYH

PXVW FORVH ZLWK D GLIIHUHQWLDO SUHVVXUH OHVV WKDQ RU HTXDO WR  SVL RXWVLGH DWPRVSKHUHWR

FRQWDLQPHQWSUHVVXUH7REHFRQVLGHUHG23(5$%/(IRURSHQLQJDYDFXXPUHOLHILVRODWLRQYDOYH

PXVWEHFDSDEOHRIRSHQLQJRQDQ(6)RSHQVLJQDODQGWREHFRQVLGHUHG23(5$%/(IRUFORVLQJ

WKHLVRODWLRQYDOYHPXVWEHFDSDEOHRIFORVLQJRQDQ(6)FORVXUHVLJQDO

$1RWHLVDGGHGWRWKH$SSOLFDELOLW\\WRVWDWHWKDWWKHYDFXXPUHOLHIYDOYHRSHUDELOLW\\IRUFORVLQJLV

RQO\\UHTXLUHGLQ02'(6DQG7KLVFKDQJHLVFRQVLVWHQWZLWK76$SSOLFDELOLW\\IRU

FRQWDLQPHQWLVRODWLRQYDOYHVWREHRSHUDEOH

$1RWHLVDGGHGWRWKH$FWLRQVWRVWDWHWKDWLIWKHHYHQWRIYDFXXPUHOLHIYDOYHOHDNDJHIURP

FRQWDLQPHQWUHVXOWVLQH[FHHGLQJWKHRYHUDOOFRQWDLQPHQWOHDNDJHUDWHDFFHSWDQFHFULWHULDWKHQ

WKHDSSOLFDEOH&RQGLWLRQVDQG5HTXLUHG$FWLRQRI/&2PXVWEHHQWHUHG7KLVFKDQJHLV

FRQVLVWHQWZLWK761RWHIRUFRQWDLQPHQWLVRODWLRQYDOYHVDQGWKHUHIRUHLVDSSOLFDEOHWRWKH

YDFXXPUHOLHIYDOYHVDQGWKHLUFRQWDLQPHQWLVRODWLRQIXQFWLRQ

76&RQGLWLRQ$LVFKDQJHGIURP³2QHYDFXXPUHOLHIIORZSDWKLQRSHUDEOH'WR³2QHYDFXXP

UHOLHIFKHFNYDOYHLQRSHUDEOHIRURSHQLQJ'DQGWKH5HTXLUHG$FWLRQLVFKDQJHGIURPDQDFWLRQIRU

UHVWRULQJ WKH ³IORZ SDWK WR 23(5$%/( VWDWXV' WR DQ DFWLRQ IRU UHVWRULQJ WKH ³FKHFN YDOYH WR

23(5$%/(IRURSHQLQJVWDWXV'7KLVUHYLVHG$FWLRQDGGUHVVHVWKHFODULILFDWLRQRIUHSODFLQJ³IORZ

SDWKV'ZLWKVSHFLILFUHTXLUHPHQWVRQYDOYHV7KHUHYLVHG$FWLRQDOVRSURYLGHVWKHFODULILFDWLRQRI

RSHQLQJIXQFWLRQYHUVXVFORVLQJIXQFWLRQ ZKLFKLVDGGUHVVHGLQWKHDGGLWLRQRIQHZ$FWLRQV&

DQG'GLVFXVVHGEHORZ 

$QHZ&RQGLWLRQ%LVWKHQSURSRVHGWRDGGUHVVWKHLQRSHUDELOLW\\IRURSHQLQJRIRQHYDFXXPUHOLHI

LVRODWLRQYDOYH7KLVQHZ&RQGLWLRQ%VWDWHV³2QHYDFXXPUHOLHILVRODWLRQYDOYHLQRSHUDEOHIRU

RSHQLQJ' ZLWK WKH 5HTXLUHG $FWLRQ WR UHVWRUH WKH YDOYH WR RSHUDEOH ZLWKLQ  KRXUV  7KHVH

PRGLILFDWLRQVWR76$FWLRQ$DQGWKHDGGLWLRQRI$FWLRQ%SHUIRUPWKHVDPHIXQFWLRQWR

PDLQWDLQYDFXXPUHOLHIRSHUDELOLW\\DVWKHFXUUHQW76&RQGLWLRQ$IRUWKHYDFXXPUHOLHIIORZ

SDWKEXWDUHPRUHVSHFLILFWRWKHYDOYHFRQILJXUDWLRQDQGWKHRSHUDELOLW\\RIWKHVHYDOYHVWRRSHQ

WRSURYLGHYDFXXPUHOLHI7KH&RPSOHWLRQ7LPHRIKRXUVUHPDLQVWKHVDPHDVWKHFXUUHQW

/&2$FWLRQ$WRUHVWRUHWKHYDFXXPUHOLHIIORZSDWK$OORZLQJRQHFKHFNYDOYH &RQGLWLRQ$ 

DQGRQHLVRODWLRQYDOYH &RQGLWLRQ% LQRSHUDEOHFRQFXUUHQWO\\SURYLGHVIRURQHFDSDEOHIORZ

SDWKWKURXJKWKHUHPDLQLQJFKHFNYDOYHDQGLVRODWLRQYDOYH

)RUWKHFRQWDLQPHQWLVRODWLRQIXQFWLRQWKHH[LVWLQJ$FWLRQLQ76IRUWKLVFRQGLWLRQZRXOG

UHTXLUHFORVLQJDQGGHDFWLYDWLQJYDOYHVVXFKWKDWWKHSHQHWUDWLRQIORZSDWKZDVLVRODWHG2QFH

FRPSOHWHGWKLVDOLJQPHQWZRXOGEHDOORZHGWRFRQWLQXHLQGHILQLWHO\\SHU76KRZHYHULQWKH

FDVHRIYDFXXPUHOLHIIORZSDWKVWKHDFWLRQZRXOGUHQGHUDOOYDFXXPUHOLHIFDSDELOLW\\LQRSHUDEOH

DQGUHTXLUHDQLPPHGLDWHSODQWVKXWGRZQSHU76FXUUHQW$FWLRQ&,QRUGHUWRDGGUHVVWKLV

XQGHVLUHGLPSDFWWKHFRQWDLQPHQWLVRODWLRQIXQFWLRQIRUWKHYDFXXPUHOLHIYDOYHVLVDGGUHVVHGLQ

SURSRVHG76$FWLRQV&DQG')RUWKHQHZ&RQGLWLRQ&ZLWKRQHRUPRUHYDFXXPUHOLHI

FKHFNYDOYHVLQRSHUDEOHIRUFORVLQJRURQHRUPRUHYDFXXPUHOLHILVRODWLRQYDOYHVLQRSHUDEOHIRU

FORVLQJ LQFOXGLQJHLWKHUWZRYDFXXPUHOLHIFKHFNYDOYHVLQRSHUDEOHIRUFORVLQJRUWZRYDFXXP

DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI

UHOLHILVRODWLRQYDOYHVLQRSHUDEOHIRUFORVLQJ SURYLGHGQHZSURSRVHG&RQGLWLRQ'LVQRWHQWHUHG

WKHSHQHWUDWLRQKDVQRWORVWLVRODWLRQFDSDELOLW\\RQO\\VLQJOHIDLOXUHSURWHFWLRQLVORVW7KHQHZ

5HTXLUHG$FWLRQ&LVWRUHVWRUHWKHDIIHFWHGYDOYH V WR23(5$%/(IRUFORVLQJVWDWXVZLWKLQ

GD\\VZKLFKZLOOUHVWRUHWKHVLQJOHIDLOXUHSURWHFWLRQIRUWKHFRQWDLQPHQWLVRODWLRQIXQFWLRQ7KH

&RPSOHWLRQ7LPHWRUHVWRUHWKHYDOYH V WR23(5$%/(IRUFORVLQJVWDWXVLQGD\\VLVUHDVRQDEOH

UHODWLYHWRWKHLPSRUWDQFHRIVXSSRUWLQJFRQWDLQPHQWLVRODWLRQFDSDELOLW\\GXULQJ02'(6

DQGZKLOHUHWDLQLQJWKHFDSDELOLW\\IRUYDFXXPUHOLHI

'XULQJWKHGD\\&RPSOHWLRQ7LPHRISURSRVHG$FWLRQ&ZKLOHUHO\\LQJRQDVLQJOHIDLOXUHLVRODWLRQ

EDUULHUWKHYDFXXPUHOLHILVRODWLRQYDOYHVZLOORQO\\EHDXWRPDWLFDOO\\RSHQHGGXHWRDQ(6)VLJQDO

RQ&RQWDLQPHQW3UHVVXUH/RZ7KHVHWSRLQWWRRSHQWKHYDOYHVUHIOHFWVDFRQWDLQPHQWSUHVVXUH

ORZHUWKDQWKHVXUURXQGLQJDWPRVSKHUH:LWKWKLVFRQWDLQPHQWGLIIHUHQWLDOSUHVVXUHDLUIORZVLQWR

FRQWDLQPHQW IURP WKH DWPRVSKHUH SUHYHQWLQJ UDGLRORJLFDO UHOHDVH IURP FRQWDLQPHQW  7KH

SUREDELOLW\\ RI WKH FRQWDLQPHQW SUHVVXUH WR GURS VLJQLILFDQWO\\ EHORZ WKH RXWVLGH DWPRVSKHULF

SUHVVXUHDQGUHTXLUHYDFXXPUHOLHILVORZ7KLVHYHQWLVSRVWXODWHGWRRFFXUZLWKDORVVRI$&

SRZHU RU&RQWDLQPHQW5HFLUFXODWLRQ&RROLQJ6\\VWHP 9&6 PDOIXQFWLRQ ZLWKDGLIIHUHQWLDO LQVLGH

WRRXWVLGH DPELHQWWHPSHUDWXUHJUHDWHUWKDQ),QDGGLWLRQ/&2DGGUHVVHVPDLQWDLQLQJ

WKHFRQWDLQPHQWLQVLGHWRRXWVLGHGLIIHUHQWLDODLUWHPSHUDWXUHWR)65SHUIRUPVD

YHULILFDWLRQRIWKHFRQWDLQPHQWLQVLGHWRRXWVLGHGLIIHUHQWLDODLUWHPSHUDWXUHHYHU\\KRXUV$V

VXFKQRFKDOOHQJHVDUHDQWLFLSDWHGWRRSHQLQJDQGUHFORVLQJWKHUHPDLQLQJUHOLHGXSRQYDFXXP

UHOLHIYDOYHFRQWDLQPHQWLVRODWLRQEDUULHU

5HJXODWRU\\*XLGHSURYLGHVJXLGDQFHIRUERWKSHUPDQHQWDQGRQHWLPHRQO\\&RPSOHWLRQ

7LPHFKDQJHVWR7HFKQLFDO6SHFLILFDWLRQV7KLVJXLGDQFHZDVXVHGWRDVVHVVWKHLPSDFWRIWKH

FRQWDLQPHQWLVRODWLRQIXQFWLRQRIWKHYDFXXPUHOLHIYDOYHVZLWKRXWVLQJOHIDLOXUHSURWHFWLRQIRU

GD\\V ZKLOH PDLQWDLQLQJ WKH YDFXXP UHOLHI IXQFWLRQ ZKLFK SUHFOXGHV DQ LPPHGLDWH SODQW

VKXWGRZQ :LWKLQWKH3UREDELOLVWLF5LVN$VVHVVPHQW 35$ WKHYDFXXPUHOLHILVRODWLRQYDOYHV

DQGWKHYDFXXPUHOLHIFKHFNYDOYHVDUHXVHGWRVXSSRUWWKHFRQWDLQPHQWLVRODWLRQIXQFWLRQ)DLOXUH

RIWKHYDFXXPUHOLHIIXQFWLRQLVQRWH[SOLFLWO\\DGGUHVVHGLQWKH35$PRGHO$ULVNDVVHVVPHQWZDV

SHUIRUPHGWRHYDOXDWHWKHLQFUHDVHLQULVNLQWKHHYHQWWKDWHLWKHUERWKYDFXXPUHOLHILVRODWLRQ

YDOYHVRUERWKYDFXXPUHOLHIFKHFNYDOYHVDUHLQRSHUDEOHIRUFORVLQJWRSHUIRUPWKHFRQWDLQPHQW

LVRODWLRQIXQFWLRQIRUGD\\V7KHULVNDVVHVVPHQWVHQVLWLYLWLHVXVHGWKHOLQNHGIDXOWWUHHPRGHO

DQG TXDQWLILFDWLRQ ILOHV IURP WKH $3 SODQW DWSRZHU LQWHUQDO HYHQWV 35$ 4XDQWLILFDWLRQ

1RWHERRN%DVHGRQ*XLGDQFHIURP5HJXODWRU\\*XLGHDQ,QFUHPHQWDO&RQGLWLRQDO&RUH

'DPDJH3UREDELOLW\\ ,&&'3 RIOHVVWKDQ(LVFRQVLGHUHGDVPDOOTXDQWLWDWLYHLPSDFWRQ

SODQWULVN$Q,QFUHPHQWDO&RQGLWLRQDO/DUJH(DUO\\5HOHDVH3UREDELOLW\\ ,&/(53 RIOHVVWKDQ

(LVDOVRFRQVLGHUHGDVPDOOTXDQWLWDWLYHLPSDFWRQSODQWULVN:LWKHLWKHUERWKYDFXXP

UHOLHILVRODWLRQYDOYHVRUERWKYDFXXPUHOLHIFKHFNYDOYHVLQRSHUDEOHIRUWKHFORVHIXQFWLRQIRU

GD\\VWKHULVNDVVHVVPHQWGHPRQVWUDWHGDQ,&&'3RI(DQGDQ,&/(53RI(

5LVNLPSDFWVZHUHDOVRHVWLPDWHGIRUDWSRZHULQWHUQDOIORRGLQJVHLVPLFDQGLQWHUQDOILUHKD]DUGV

DOORWKHULGHQWLILHGH[WHUQDOKD]DUGVDUHVFUHHQHGRXWLQWKHDWSRZHUH[WHUQDOKD]DUGDVVHVVPHQW

7KHHVWLPDWHG,&&'3DQG,&/(53YDOXHVIRUDOODWSRZHUKD]DUGVZLWKHLWKHUERWKYDFXXPUHOLHI

LVRODWLRQYDOYHVRUERWKYDFXXPUHOLHIFKHFNYDOYHVLQRSHUDEOHIRUWKHFORVHIXQFWLRQIRUGD\\V

DUH(DQG(UHVSHFWLYHO\\7KHUHIRUHWKHUHLVDVPDOODQGDFFHSWDEOHTXDQWLWDWLYH

LPSDFWRQSODQWULVNGXHWRORVVRIVLQJOHIDLOXUHSURWHFWLRQLQWKHFRQWDLQPHQWLVRODWLRQIXQFWLRQE\\

LQRSHUDELOLW\\RIWKHFORVHIXQFWLRQRIHLWKHURQHRUERWKYDFXXPUHOLHILVRODWLRQYDOYHVRURQHRU

ERWKYDFXXPUHOLHIFKHFNYDOYHVIRUDQDOORZHG&RPSOHWLRQ7LPHRIGD\\VSULRUWRDVKXWGRZQ

DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI

7KH$335$ZDVGHYHORSHGWRVXSSRUWWKHDSSOLFDWLRQIRU8QLWHG6WDWHV'HVLJQ&HUWLILFDWLRQ

RIWKH$3QXFOHDUSODQW$GGLWLRQDO$3SODQWVSHFLILFWKHUPDOK\\GUDXOLF 7+ DQDO\\VHV

DUHSHUIRUPHGLQRUGHUWRGHWHUPLQHWKHV\\VWHPVXFFHVVFULWHULD7KHFRUHGDPDJHIUHTXHQF\\

&') DQGODUJHUHOHDVHIUHTXHQF\\ /5) DUHFDOFXODWHGIRULQWHUQDOHYHQWV6HOHFWHGLQWHUQDO

KD]DUGHYHQWVDQGVKXWGRZQPRGHOVDUHDOVRTXDQWLWDWLYHO\\DVVHVVHGWRGHULYHSODQWLQVLJKWVDQG

SODQW ULVN FRQFOXVLRQV  6HLVPLF HYHQWV DUH DVVHVVHG XVLQJ GHWDLOHG 35$ DSSURDFK  2WKHU

H[WHUQDOKD]DUGVDUHHYDOXDWHGZLWKDTXDOLWDWLYHDSSURDFK7KH$335$PRGHOVKDYHEHHQ

XSGDWHG IROORZLQJ VWDQGDUGV DQG PHWKRGRORJLHV DSSOLFDEOH WR SUHSDULQJ D 35$ PRGHO IRU

RSHUDWLRQVLQFOXGLQJ

x

$60($165$6D³6WDQGDUGIRU/HYHO/DUJH5HOHDVH(DUO\\5HOHDVH)UHTXHQF\\

3UREDELOLVWLF5LVN$VVHVVPHQWIRU1XFOHDU3RZHU3ODQW$SSOLFDWLRQV'$PHULFDQ6RFLHW\\RI

0HFKDQLFDO(QJLQHHUV

x

8615&5HJXODWRU\\*XLGH³$Q$SSURDFKIRU'HWHUPLQLQJWKH7HFKQLFDO$GHTXDF\\

RI3UREDELOLVWLF5LVN$VVHVVPHQW5HVXOWVIRU5LVN,QIRUPHG$FWLYLWLHV'5HYLVLRQ

x

185(*&5³,QGXVWU\\$YHUDJH3HUIRUPDQFH&RPSRQHQWVDQG,QLWLDWLQJ(YHQWVDW

86&RPPHUFLDO1XFOHDU3RZHU3ODQWV'

x

(35,  ³*XLGHOLQHV IRU 3HUIRUPDQFH RI,QWHUQDO )ORRGLQJ 3UREDELOLVWLF 5LVN

$VVHVVPHQW'(OHFWULF3RZHU5HVHDUFK,QVWLWXWH'

x

8615&185(*&5³(35,15&5(6)LUH35$0HWKRGRORJ\\IRU1XFOHDU3RZHU

)DFLOLWLHV'

x

$16,$16³([WHUQDO(YHQWV35$0HWKRGRORJ\\'

7KHUHIRUHWKHWHFKQLFDODGHTXDF\\RIWKH35$DQGWKHULVNHYDOXDWLRQVSHUIRUPHGWRVXSSRUWWKLV

SURSRVHGFKDQJHDUHVXIILFLHQWWRSURYLGHFRQILGHQFHLQWKHUHVXOWVVXFKWKDWWKH35$FDQEH

XVHGLQUHJXODWRU\\GHFLVLRQPDNLQJ

)RUWKHQHZ76&RQGLWLRQ'ZLWKRQHRUPRUHYDFXXPUHOLHILVRODWLRQYDOYHVLQRSHUDEOHIRU

FORVLQJDQGRQHRUPRUHYDFXXPUHOLHIFKHFNYDOYHVLVLQRSHUDEOHIRUFORVLQJWKHQHZ5HTXLUHG

$FWLRQ'LVWRUHVWRUHHLWKHUERWKYDFXXPUHOLHILVRODWLRQYDOYHVWR23(5$%/(IRUFORVLQJVWDWXV

RU WR UHVWRUH ERWK YDFXXP UHOLHI FKHFN YDOYHV WR 23(5$%/( IRU FORVLQJ VWDWXV LQ RUGHU WR

HVWDEOLVKDFRQWDLQPHQWLVRODWLRQEDUULHU)RU$FWLRQ'WKH&RPSOHWLRQ7LPHRIKRXUWRUHVWRUH

WKHYDOYHVWR23(5$%/(IRUFORVLQJLVWKHVDPHDV76$FWLRQ%LQZKLFKWKHUHLVQRLVRODWLRQ

EDUULHUDYDLODEOHLQWKHSHQHWUDWLRQIORZSDWK

LWKWKHDGGLWLRQRIWKHQHZ$FWLRQVLQ76WKHFXUUHQW&RQGLWLRQ%DQGDVVRFLDWHG5HTXLUHG

$FWLRQVKDYHDQHGLWRULDOXSGDWHIURP³%'WR³('7KHFXUUHQW&RQGLWLRQ&DQGDVVRFLDWHG5HTXLUHG

$FWLRQVKDYHDQHGLWRULDOXSGDWHIURP³&'WR³)',QDGGLWLRQUHQXPEHUHG&RQGLWLRQ)LVQRZ

DSSOLFDEOHLIWKH5HTXLUHG$FWLRQDQGDVVRFLDWHGFRPSOHWLRQWLPHVIRU&RQGLWLRQV$%&'RU(

DUHQRWPHWZKLFKFRYHUVWKHQHZ&RQGLWLRQVDGGHGWRDGGUHVVERWKWKHYDFXXPUHOLHIIXQFWLRQ

DQGWKHFRQWDLQPHQWLVRODWLRQIXQFWLRQVRIWKHYDOYHVZKLOHRSHUDWLQJLQ02'(RU7KH

FRUUHVSRQGLQJ5HTXLUHG$FWLRQVUHPDLQWKHVDPHDVWKHFXUUHQW76LQWKHHYHQWWKDWWKH

YDFXXPUHOLHIFDSDELOLW\\RUWKHFRQWDLQPHQWWHPSHUDWXUHGLIIHUHQWLDOFDQQRWEHUHVWRUHGZLWKLQWKH

UHTXLUHG&RPSOHWLRQ7LPHDQGQRZDOVRDGGUHVVHVLIWKHFRQWDLQPHQWLVRODWLRQFORVHIXQFWLRQ

FDQQRW EH UHVWRUHG ZLWKLQ WKH UHTXLUHG &RPSOHWLRQ 7LPH  &RQGLWLRQ ) DOVR LQFOXGHV QHZ

&RQGLWLRQVWRDGGUHVVWZRYDFXXPUHOLHIFKHFNYDOYHVLQRSHUDEOHIRURSHQLQJRUWZRYDFXXP

UHOLHILVRODWLRQYDOYHVLQRSHUDEOHIRURSHQLQJLQ02'(RUZKLFKFRUUHVSRQGVWRWKH

DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI

FKDQJHLQ/&2IURP³IORZSDWKV'WR³FKHFNYDOYHVDQGYDFXXPUHOLHILVRODWLRQYDOYHV'7KH

FRUUHVSRQGLQJ5HTXLUHG$FWLRQVUHPDLQWKHVDPHDVWKHFXUUHQW76LQWKHHYHQWWKDWWKH

YDFXXPUHOLHIFDSDELOLW\\LVQRWDYDLODEOHGXHWRWKHORVVRIDOODYDLODEOHIORZSDWKV

7KHFXUUHQW&RQGLWLRQ'DQGDVVRFLDWHG5HTXLUHG$FWLRQVDUHFKDQJHGIURP³WR³*')RU

UHQXPEHUHG&RQGLWLRQ*WKHUHTXLUHPHQWVEHLQJUHORFDWHGIURP/&2DUHQRWUHTXLUHGLQ

02'(RUVRWKLVFRQGLWLRQLVRQO\\DSSOLFDEOHLI&RQGLWLRQ$%RU(DQGWKHDVVRFLDWHGDFWLRQV

WRUHVWRUHYDFXXPUHOLHIFDSDELOLW\\FDQQRWEHSHUIRUPHGZLWKLQWKHUHTXLUHG&RPSOHWLRQ7LPHRU

WKHFRQWDLQPHQWLQVLGHWRRXWVLGHWHPSHUDWXUHGLIIHUHQWLDOFDQQRWEHUHVWRUHGZLWKLQWKHUHTXLUHG

FRPSOHWLRQWLPHRULIWZRYDFXXPUHOLHIFKHFNYDOYHVDUHLQRSHUDEOHIRURSHQLQJRULIWZRYDFXXP

UHOLHILVRODWLRQYDOYHVDUHLQRSHUDEOHIRURSHQLQJ7KHFXUUHQW&RQGLWLRQRI%RWKYDFXXPUHOLHI

IORZSDWKVLQRSHUDEOHLVPRUHVSHFLILFDOO\\LGHQWLILHGDVHLWKHUWZRYDFXXPUHOLHIFKHFNYDOYHV

LQRSHUDEOHIRURSHQLQJRUWZRYDFXXPUHOLHILVRODWLRQYDOYHVLQRSHUDEOHIRURSHQLQJDVWKHVH

UHIOHFWWKHWZRSRVVLEOHFRQGLWLRQVZKHUHDOOUHOLHIFDSDELOLW\\LVLQRSHUDEOH7KH5HTXLUHG$FWLRQV

DQG&RPSOHWLRQ7LPHVUHPDLQWKHVDPHDVWKHFXUUHQW76IRUORVVRIDOOYDFXXPUHOLHIIORZ

SDWKVRUORVVRIWKHDOORZDEOHFRQWDLQPHQWWHPSHUDWXUHGLIIHUHQWLDOGXULQJ02'(6DQG

$QHZ65LVDGGHGWRLQFOXGHYHULILFDWLRQWKDWHDFKYDFXXPUHOLHILVRODWLRQYDOYHLVFORVHG

HYHU\\GD\\VZLWKH[FHSWLRQVIRUZKHQWKHYDOYHVDUHRSHQIRURWKHUVXUYHLOODQFHVRULIWKH\\DUH

SHUIRUPLQJ D YDFXXP UHOLHI IXQFWLRQ  0HHWLQJ RQH RI WKHVH 1RWHG H[FHSWLRQV SURYLGHV DQ

DOORZDQFHIRUYDFXXPUHOLHIYDOYHVWREHRSHQDQGQRWFRQVLGHUHGLQRSHUDEOH7KLV65HQVXUHV

WKDWWKHYDFXXPUHOLHILVRODWLRQYDOYHVDUHFORVHGDVUHTXLUHGRULIRSHQWKHYDOYHVDUHRSHQIRU

DQDOORZDEOHUHDVRQ7KHYDFXXPUHOLHILVRODWLRQYDOYHVDUHQRUPDOO\\FORVHG7KHIUHTXHQF\\RI

GD\\V LV DSSURSULDWH FRQVLGHULQJ WKH YDOYHV VKRXOG RQO\\ EH RSHQHG WR UHOLHYH YDFXXP RU

PDQXDOO\\RSHQHGWRSHUIRUP6XUYHLOODQFHVDQGWKHSUREDELOLW\\RIWKHYDOYHPLVDOLJQPHQWLVORZ

7KHUHIRUH YHULILFDWLRQ HYHU\\  GD\\V LV DSSURSULDWH FRQVLGHULQJ WKH SUREDELOLW\\ RI WKH YDOYH

PLVDOLJQPHQWLVORZ

7KHFXUUHQW65KDVDQHGLWRULDOUHQXPEHULQJXSGDWHWR65DQGDFODULILFDWLRQIURP

³YHULI\\HDFKYDFXXPUHOLHIIORZSDWK'WR³YHULI\\HDFKYDFXXPUHOLHIYDOYH'(DFKYDFXXPUHOLHI

YDOYHLVWREHYHULILHG23(5$%/(ZKLFKLQFOXGHVERWKRSHUDEOHIRURSHQLQJDQGRSHUDEOHIRU

FORVLQJLQDFFRUGDQFHZLWKWKH,QVHUYLFH7HVWLQJ3URJUDP

7KHFXUUHQW65KDVDQHGLWRULDOUHQXPEHULQJXSGDWHWR65DQGLVPRGLILHGWR

DGGUHVVERWKWKHDXWRPDWLFRSHQLQJDQGFORVLQJRIWKHYDFXXPUHOLHILVRODWLRQYDOYH65

LVWRYHULI\\HDFKYDFXXPUHOLHILVRODWLRQYDOYHDFWXDWHVRQDQDFWXDORUVLPXODWHGVLJQDOHYHU\\

PRQWKV  )RU YDFXXP UHOLHI WKHVH YDOYHV PXVW GHPRQVWUDWH WKH FDSDELOLW\\ WR RSHQ E\\ DQ

DFWXDWLRQVLJQDO)RUFRQWDLQPHQWLVRODWLRQWKHVHYDOYHVPXVWGHPRQVWUDWHWKHFDSDELOLW\\WRFORVH

E\\DQDFWXDWLRQVLJQDO7KHVXUYHLOODQFHIUHTXHQF\\RIPRQWKVLVWKHVDPHDVWKHFXUUHQW

76IRUYHULILFDWLRQRIWKHDFWXDWLRQWRUHOLHYHYDFXXPRQDQDFWXDORUVLPXODWHGVLJQDO ZKLFK

RQO\\ DSSOLHV WR WKH YDFXXP UHOLHI LVRODWLRQ YDOYH  DQG WKH VDPH DV 76  65  IRU

DXWRPDWLFFRQWDLQPHQWLVRODWLRQYDOYHV

7KHUHLVQRLPSDFWWRWKHFRQWDLQPHQWH[WHUQDOSUHVVXUHDQDO\\VLVLQ8)6$56XEVHFWLRQ

([WHUQDO3UHVVXUHDQDO\\VLVDVDUHVXOWRIWKLVFKDQJH7KHSURSRVHGFKDQJHVGRQRWUHVXOWLQD

FKDQJHWRWKHFRQWDLQPHQWLVRODWLRQRUFRQWDLQPHQWYDFXXPUHOLHIGHVLJQ7KHSURSRVHGFKDQJHV

WRWKHDFWLRQVIRULQRSHUDEOHYDOYHVFRQWLQXHWRDVVXUHWKHFDSDELOLW\\IRUDSSURSULDWHFRQWDLQPHQW

LVRODWLRQEDUULHUDQGYDFXXPUHOLHIFDSDELOLW\\FRQVLVWHQWZLWKWKHDSSURSULDWHGHVLJQSULRULWL]DWLRQ

DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI

7KHUHDUHQRLPSDFWVDGYHUVHWRVDIHW\\DVDUHVXOWRIWKHVHFKDQJHVWR76DQG76

7KHFKDQJHWR76WRUHPRYHWKHYDFXXPUHOLHIYDOYHVIURP76GRHVQRWKDYHDQ

DGYHUVHLPSDFWWRVDIHW\\DVWKHFRQWDLQPHQWLVRODWLRQIXQFWLRQRIWKHYDOYHVLVDGGUHVVHGLQWKH

FKDQJHVWR767KLVFKDQJHSURYLGHVDFRUUHFWLRQWR76VXFKWKDWWKHYDFXXPUHOLHI

YDOYHVFDQSHUIRUPWKHLUYDFXXPUHOLHIIXQFWLRQDQGDUHQRWUHTXLUHGWREHORFNHGFORVHGLQWKH

HYHQW D FRQWDLQPHQW YDFXXP UHOLHI YDOYH ZKLFK LV DOVR DQ LVRODWLRQ YDOYH  LV LGHQWLILHG DV

LQRSHUDEOH7KHFKDQJHVWR76DGGUHVVERWKRSHQLQJIRUYDFXXPUHOLHIDQGFORVLQJIRU

FRQWDLQPHQWLVRODWLRQVXFKWKDWERWKVDIHW\\IXQFWLRQVRIWKHYDFXXPUHOLHIYDOYHVDUHDGGUHVVHG

E\\/&27KHUHYLVHG6XUYHLOODQFH5HTXLUHPHQWVHQVXUHERWKWKHYDFXXPUHOLHIIXQFWLRQ

DQGFRQWDLQPHQWLVRODWLRQIXQFWLRQVRIWKHYDOYHVDUHSHULRGLFDOO\\YHULILHG



3URSRVHG/LFHQVLQJ%DVLV&KDQJHV

3URSRVHGFKDQJHVLQFOXGHWKHIROORZLQJ&2/$SSHQGL[$76FKDQJHV

x

76  &RQWDLQPHQW,VRODWLRQ 9DOYHV /&2 VWDWHPHQW LV UHYLVHG IURP ³H[FHSW IRU WKH

FRQWDLQPHQWLVRODWLRQYDOYHVDVVRFLDWHGZLWKFORVHGV\\VWHPV'WR³H[FHSWIRUFRQWDLQPHQW

LVRODWLRQYDOYHVDVVRFLDWHGZLWKFORVHGV\\VWHPVDQGIRUYDFXXPUHOLHIYDOYHV'

x

769DFXXP5HOLHI9DOYHV

o /&2 UHSODFH ³IORZ SDWKV' ZLWK ³FKHFN YDOYHV DQG WZR YDFXXP UHOLHI LVRODWLRQ

YDOYHV'

o $SSOLFDELOLW\\UHYLVHGWRDGGQHZ1RWH³9DFXXPUHOLHIYDOYH23(5$%,/,7<IRU

FORVLQJLVRQO\\UHTXLUHGLQ02'(6DQG'

o $FWLRQV KHDGLQJ DGGV QHZ 1RWH  ³(QWHU DSSOLFDEOH &RQGLWLRQV DQG 5HTXLUHG

$FWLRQVRI/&2³&RQWDLQPHQW'ZKHQYDFXXPUHOLHIYDOYHOHDNDJHUHVXOWVLQ

H[FHHGLQJWKHRYHUDOOFRQWDLQPHQWOHDNDJHUDWHDFFHSWDQFHFULWHULD'

o $FWLRQ$UHYLVHG



&RQGLWLRQUHSODFH³IORZSDWKLQRSHUDEOH'ZLWK³FKHFNYDOYHLQRSHUDEOHIRU

RSHQLQJ'



5HTXLUHG $FWLRQ UHSODFH ³IORZ SDWK' ZLWK ³FKHFN YDOYH' DQG DGG ³IRU

RSHQLQJ'EHWZHHQ³23(5$%/('DQG³VWDWXV'

o 1HZ$FWLRQ%DGGHGZLWK



&RQGLWLRQ % VWDWLQJ  ³2QH YDFXXP UHOLHI LVRODWLRQ YDOYH LQRSHUDEOH IRU

RSHQLQJ'



5HTXLUHG $FWLRQ % VWDWLQJ  ³5HVWRUH YDFXXP UHOLHI LVRODWLRQ YDOYH WR

23(5$%/(IRURSHQLQJVWDWXV'



&RPSOHWLRQ7LPHVWDWLQJ³KRXUV'

DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI

o 1HZ$FWLRQ&LVDGGHGZLWK



&RQGLWLRQVWDWLQJ³2QHRUPRUHYDFXXPUHOLHIFKHFNYDOYHVLQRSHUDEOHIRU

FORVLQJ 25 2QH RU PRUH YDFXXP UHOLHI LVRODWLRQ YDOYHV LQRSHUDEOH IRU

FORVLQJ'



5HTXLUHG$FWLRQ&VWDWLQJ³5HVWRUHDIIHFWHGYDOYH V WR23(5$%/(IRU

FORVLQJVWDWXV'ZLWK&RPSOHWLRQ7LPH³GD\\V'

o 1HZ$FWLRQ'LVDGGHGZLWK



&RQGLWLRQVWDWLQJ³2QHRUPRUHYDFXXPUHOLHIFKHFNYDOYHVLQRSHUDEOHIRU

FORVLQJ $1' 2QH RU PRUH YDFXXP UHOLHI LVRODWLRQ YDOYHV LQRSHUDEOH IRU

FORVLQJ'



5HTXLUHG$FWLRQ'VWDWLQJ³5HVWRUHERWKYDFXXPUHOLHIFKHFNYDOYHVWR

23(5$%/(IRUFORVLQJVWDWXV'ZLWK&RPSOHWLRQ7LPH³KRXU'



5HTXLUHG$FWLRQ'VWDWLQJ³5HVWRUHERWKYDFXXPUHOLHILVRODWLRQYDOYHV

WR23(5$%/(IRUFORVLQJVWDWXV'ZLWK&RPSOHWLRQ7LPH³KRXU'

o &XUUHQW$FWLRQ&UHQXPEHUHG)DQG



)LUVW &RQGLWLRQ UHYLVHG WKH UHIHUHQFH WR ³&RQGLWLRQ $ RU %' WR EHFRPH

³&RQGLWLRQ$%&'RU('



6HFRQG &RQGLWLRQ VWDWLQJ ³%RWK YDFXXP UHOLHI IORZ SDWKV LQRSHUDEOH' LV

UHYLVHGWR³7ZRYDFXXPUHOLHIFKHFNYDOYHVLQRSHUDEOHIRURSHQLQJ'



1HZWKLUG&RQGLWLRQDGGHGVWDWLQJ³257ZRYDFXXPUHOLHILVRODWLRQYDOYHV

LQRSHUDEOHIRURSHQLQJLQ02'(RU'

o &XUUHQW$FWLRQ'UHQXPEHUHG*DQG



)LUVW &RQGLWLRQ UHYLVHG WKH UHIHUHQFH WR ³&RQGLWLRQ $ RU %' WR EHFRPH

³&RQGLWLRQ$%RU('



6HFRQG &RQGLWLRQ VWDWLQJ ³%RWK YDFXXP UHOLHI IORZ SDWKV LQRSHUDEOH' LV

UHYLVHGWR³7ZRYDFXXPUHOLHIFKHFNYDOYHVLQRSHUDEOHIRURSHQLQJ'



1HZWKLUG&RQGLWLRQDGGHGVWDWLQJ³257ZRYDFXXPUHOLHILVRODWLRQYDOYHV

LQRSHUDEOHIRURSHQLQJLQ02'(RU'

o 1HZ6XUYHLOODQFH5HTXLUHPHQW65DGGHG



6XUYHLOODQFHVWDWLQJ³9HULI\\HDFKYDFXXPUHOLHILVRODWLRQYDOYHLVFORVHG'



6XUYHLOODQFH 1RWH  VWDWLQJ  ³1RW UHTXLUHG WR EH PHW IRU YDFXXP UHOLHI

YDOYHVRSHQGXULQJ6XUYHLOODQFHV'

DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI



6XUYHLOODQFH 1RWH  VWDWLQJ  ³1RW UHTXLUHG WR EH PHW IRU YDFXXP UHOLHI

YDOYHVRSHQZKHQSHUIRUPLQJWKHLUYDFXXPUHOLHIIXQFWLRQ'



)UHTXHQF\\VWDWLQJ³GD\\V'

o &XUUHQW65



5HQXPEHUHGWR65



5HYLVH³IORZSDWK'WR³YDOYH'

o &XUUHQW65



5HQXPEHUHGWR65



5HYLVH³UHOLHIYDOYHDFWXDWHVWRUHOLHYHYDFXXPRQDQDFWXDORUVLPXODWHG

VLJQDO'WR³UHOLHILVRODWLRQYDOYHDFWXDWHVRQDFWXDORUVLPXODWHGVLJQDOV'

&RQIRUPLQJ 76 %DVHV FKDQJHV ZLOO EH LQFRUSRUDWHG IROORZLQJ 15& DSSURYDO RI WKH OLFHQVH

DPHQGPHQW UHTXHVW LQ DFFRUGDQFH ZLWK 76  7HFKQLFDO 6SHFLILFDWLRQ %DVHV &RQWURO

3URJUDP7KHPDUNXSVVKRZLQJWKHVHFKDQJHVDUHSURYLGHGLQ(QFORVXUHIRULQIRUPDWLRQRQO\\



6XPPDU\\

7KHSURSRVHGFKDQJHVZRXOGDPHQG&2/$SSHQGL[$7HFKQLFDO6SHFLILFDWLRQV76WR

H[FOXGH WKH YDFXXP UHOLHI FRQWDLQPHQW LVRODWLRQ YDOYHV LHWKH ³FORVH' IXQFWLRQ  DQG DPHQG

76WRDGGUHVVRSHUDELOLW\\RIWKHYDFXXPUHOLHIYDOYHVFRQWDLQPHQWLVRODWLRQIXQFWLRQ$FWLRQV

DQG6XUYHLOODQFHV

7KHSURSRVHGFKDQJHVGRQRWUHVXOWLQDFKDQJHWRWKHFRQWDLQPHQWLVRODWLRQRUFRQWDLQPHQW

YDFXXPUHOLHIGHVLJQ7KHSURSRVHGFKDQJHVWRWKHDFWLRQVIRULQRSHUDEOHYDOYHVFRQWLQXHWR

DVVXUHWKHFDSDELOLW\\IRUDSSURSULDWHFRQWDLQPHQWLVRODWLRQEDUULHUDQGYDFXXPUHOLHIFDSDELOLW\\

FRQVLVWHQWZLWKWKHDSSURSULDWHGHVLJQSULRULWL]DWLRQ

7KH SURSRVHG FKDQJHV ZLOO QRW DGYHUVHO\\ DIIHFW VDIHW\\UHODWHG HTXLSPHQW RU IXQFWLRQ GHVLJQ

IXQFWLRQUDGLRDFWLYHPDWHULDOEDUULHURUVDIHW\\DQDO\\VLV$GGLWLRQDOO\\WKHSURSRVHGFKDQJHVKDYH

QRDGYHUVHLPSDFWRQWKHHPHUJHQF\\SODQRUWKHSK\\VLFDOVHFXULW\\SODQLPSOHPHQWDWLRQEHFDXVH

WKHUHLVQRFKDQJHWRSK\\VLFDODFFHVVWRFUHGLWHGHTXLSPHQWLQVLGHWKH1XFOHDU,VODQGDQGQR

DGYHUVHLPSDFWRQWKHDELOLW\\WRPRQLWRUSODQWSDUDPHWHUVSRVWDFFLGHQW

DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI



5(*8/$725<(9$/8$7,21

 $SSOLFDEOH5HJXODWRU\\5HTXLUHPHQWV&ULWHULD

&)5Technical specificationsSDUDJUDSK F 7HFKQLFDOVSHFLILFDWLRQVUHTXLUHVLQFOXGLQJ

LWHPVLQWKHIROORZLQJFDWHJRULHV  6DIHW\\OLPLWVOLPLWLQJVDIHW\\V\\VWHPVHWWLQJVDQGOLPLWLQJ

FRQWUROVHWWLQJV  /LPLWLQJFRQGLWLRQVIRURSHUDWLRQDQG  6XUYHLOODQFHUHTXLUHPHQWV7KH

VDIHW\\OLPLWVWKHOLPLWLQJVDIHW\\V\\VWHPVHWWLQJVDQGOLPLWLQJFRQWUROVHWWLQJVDUHQRWDIIHFWHGZLWK

WKLVSURSRVHGDPHQGPHQW,QDGGLWLRQWKHSURSRVHGFKDQJHVWRWKHSODQWVSHFLILF7HFKQLFDO

6SHFLILFDWLRQV OLPLWLQJ FRQGLWLRQV IRU RSHUDWLRQ DSSOLFDELOLW\\ DFWLRQV DQG VXUYHLOODQFH

UHTXLUHPHQWVDVMXVWLILHGE\\WKLVOLFHQVHDPHQGPHQWUHTXHVWFRQWLQXHWRPHHWWKHVFRSHUHTXLUHG

E\\&)5 F 

&)5 F UHTXLUHV15&DSSURYDOIRUDQ\\PRGLILFDWLRQWRDGGLWLRQWRRUGHOHWLRQIURPWKH

WHUPVDQGFRQGLWLRQVRID&RPELQHG/LFHQVH &2/ 7KLVDFWLYLW\\LQYROYHVFKDQJHVWRSODQW

VSHFLILF7HFKQLFDO6SHFLILFDWLRQV &2/$SSHQGL[$ 7KHUHIRUHWKLVDFWLYLW\\UHTXLUHVDSURSRVHG

DPHQGPHQWWRWKH&2/

&)5$SSHQGL['9,,,&VWDWHVWKDWDIWHULVVXDQFHRIDOLFHQVH³&KDQJHVWRWKHSODQW

VSHFLILF 76 7HFKQLFDO 6SHFLILFDWLRQV  ZLOO EH WUHDWHG DV OLFHQVH DPHQGPHQWV XQGHU

&)5'  &)5  DGGUHVVHV WKH DSSOLFDWLRQV IRU DPHQGPHQWV RI OLFHQVHV

FRQVWUXFWLRQ SHUPLWV DQG HDUO\\ VLWH SHUPLWV  $V GLVFXVVHG DERYH FKDQJHV WR SODQWVSHFLILF

7HFKQLFDO6SHFLILFDWLRQV &2/$SSHQGL[$ DUHUHTXHVWHG7KHUHIRUH15&DSSURYDOLVUHTXLUHG

IRUWKHVHSODQWVSHFLILF76FKDQJHV

7KH SURSRVHG FKDQJHV KDYH EHHQ HYDOXDWHG WR GHWHUPLQH ZKHWKHU DSSOLFDEOH &)5

$SSHQGL[ $ *HQHUDO 'HVLJQ &ULWHULD *'&  FRQWLQXH WR EH PHW ,W ZDV GHWHUPLQHG WKDW WKH

SURSRVHGFKDQJHVGRQRWDIIHFWFRQIRUPDQFHZLWKWKH*'&GLIIHUHQWO\\WKDQGHVFULEHGLQWKHSODQW

VSHFLILF'&'RU8)6$5DVGHVFULEHGEHORZ



  • '&Containment designVWDWHV³5HDFWRUFRQWDLQPHQWDQGDVVRFLDWHGV\\VWHPVVKDOOEH

SURYLGHG WR HVWDEOLVK DQ HVVHQWLDOO\\ OHDNWLJKW EDUULHU DJDLQVW WKH XQFRQWUROOHG UHOHDVH RI

UDGLRDFWLYLW\\ WR WKH HQYLURQPHQW DQG WR DVVXUH WKDW WKH FRQWDLQPHQW GHVLJQ FRQGLWLRQV

LPSRUWDQWWRVDIHW\\DUHQRWH[FHHGHGIRUDVORQJDVSRVWXODWHGDFFLGHQWFRQGLWLRQVUHTXLUH'



7KHSURSRVHGFKDQJHVGRQRWUHVXOWLQDFKDQJHWRWKHFRQWDLQPHQWLVRODWLRQRUFRQWDLQPHQW

YDFXXPUHOLHIGHVLJQ7KHSURSRVHGFKDQJHVWRWKHDFWLRQVIRULQRSHUDEOHYDOYHVFRQWLQXHWR

DVVXUHWKHFDSDELOLW\\IRUDSSURSULDWHFRQWDLQPHQWLVRODWLRQEDUULHUDQGYDFXXPUHOLHIFDSDELOLW\\

FRQVLVWHQWZLWKWKHDSSURSULDWHGHVLJQSULRULWL]DWLRQ



 3UHFHGHQW

1RSUHFHGHQWVDUHLGHQWLILHG



DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI

 6LJQLILFDQW+D]DUGV&RQVLGHUDWLRQ

6RXWKHUQ1XFOHDU2SHUDWLQJ&RPSDQ\\ 61& LVUHTXHVWLQJDQDPHQGPHQWWR&RPELQHG/LFHQVH

&2/ 1RV13)DQG13)IRU9RJWOH(OHFWULF*HQHUDWLQJ3ODQW 9(*3 8QLWVDQG

UHVSHFWLYHO\\  7KH OLFHQVH DPHQGPHQW UHTXHVW /$5  SURSRVHV FKDQJHV WR &2/ $SSHQGL[$

76 &RQWDLQPHQW,VRODWLRQ 9DOYHV DQG 76  9DFXXP 5HOLHI 9DOYHV WR H[FOXGH WKH

YDFXXP UHOLHI FRQWDLQPHQW LVRODWLRQ YDOYHV IURP 76 /&2  DQG DGGUHVV WKH FRQWDLQPHQW

LVRODWLRQIXQFWLRQRSHUDELOLW\\$FWLRQVDQG6XUYHLOODQFHVLQ76$QHYDOXDWLRQWRGHWHUPLQH

ZKHWKHURUQRWDVLJQLILFDQWKD]DUGVFRQVLGHUDWLRQLVLQYROYHGZLWKWKHSURSRVHGDPHQGPHQWZDV

FRPSOHWHG E\\ IRFXVLQJ RQ WKH WKUHH VWDQGDUGV VHW IRUWK LQ  &)5  F  ³,VVXDQFH RI

DPHQGPHQW'DVGLVFXVVHGEHORZ





'RHV WKH SURSRVHG DPHQGPHQW LQYROYH D VLJQLILFDQW LQFUHDVH LQ WKH

SUREDELOLW\\RUFRQVHTXHQFHVRIDQDFFLGHQWSUHYLRXVO\\HYDOXDWHG"

5HVSRQVH

1R

7KH SURSRVHG FKDQJHV GR QRW DIIHFW WKH VDIHW\\ OLPLWV RU OLPLWLQJ VDIHW\\ V\\VWHP

VHWWLQJV DV UHTXLUHG E\\ WKH SODQWVSHFLILF 7HFKQLFDO 6SHFLILFDWLRQV 76   7KH

SURSRVHG FKDQJHV GR QRW DGYHUVHO\\ DIIHFW WKH RSHUDWLRQ RI DQ\\ VWUXFWXUHV

V\\VWHPVRUFRPSRQHQWV 66&V DVVRFLDWHGZLWKDQDFFLGHQWLQLWLDWRURULQLWLDWLQJ

VHTXHQFH RI HYHQWV  7KH SURSRVHG FKDQJHV FRQWLQXH WR PDLQWDLQ WKH LQLWLDO

FRQGLWLRQVDQGRSHUDWLQJOLPLWVDVVXPHGGXULQJQRUPDORSHUDWLRQDVVXPHGE\\WKH

DFFLGHQW DQDO\\VLV DQG DVVXPHG LQ DQWLFLSDWHG RSHUDWLRQDO RFFXUUHQFHV

7KHUHIRUHWKHSURSRVHGFKDQJHVGRQRWUHVXOWLQDQ\\LQFUHDVHLQSUREDELOLW\\RIDQ

DQDO\\]HGDFFLGHQWRFFXUULQJ

7KHSURSRVHGFKDQJHVGRQRWLQYROYHDFKDQJHWRDQ\\PLWLJDWLRQVHTXHQFHRUWKH

SUHGLFWHGUDGLRORJLFDOUHOHDVHVGXHWRSRVWXODWHGDFFLGHQWFRQGLWLRQV7KXVWKH

FRQVHTXHQFHVRIWKHDFFLGHQWVSUHYLRXVO\\HYDOXDWHGDUHQRWDGYHUVHO\\DIIHFWHG

7KHUHIRUHWKHSURSRVHGDPHQGPHQWGRHVQRWLQYROYHDVLJQLILFDQWLQFUHDVHLQWKH

SUREDELOLW\\RUFRQVHTXHQFHVRIDQDFFLGHQWSUHYLRXVO\\HYDOXDWHG





'RHVWKHSURSRVHGDPHQGPHQWFUHDWHWKHSRVVLELOLW\\RIDQHZRUGLIIHUHQW

NLQGRIDFFLGHQWIURPDQ\\DFFLGHQWSUHYLRXVO\\HYDOXDWHG"

5HVSRQVH

1R

7KH SURSRVHG FKDQJHV KDYH EHHQ IRXQG WR FRQWLQXH WR SURYLGH WKH UHTXLUHG

IXQFWLRQDOFDSDELOLW\\RIWKHVDIHW\\V\\VWHPVIRUSUHYLRXVO\\HYDOXDWHGDFFLGHQWVDQG

DQWLFLSDWHGRSHUDWLRQDORFFXUUHQFHV7KHSURSRVHGUHYLVLRQVGRQRWFKDQJHWKH

IXQFWLRQRIWKHUHODWHGV\\VWHPVDQGWKXVWKHFKDQJHVGRQRWLQWURGXFHDQHZ

IDLOXUHPRGHPDOIXQFWLRQRUVHTXHQFHRIHYHQWVWKDWFRXOGDGYHUVHO\\DIIHFWVDIHW\\

RUVDIHW\\UHODWHGHTXLSPHQW

7KHUHIRUHWKHSURSRVHGDPHQGPHQWGRHVQRWFUHDWHWKHSRVVLELOLW\\RIDQHZRU

GLIIHUHQWNLQGRIDFFLGHQWIURPDQ\\DFFLGHQWSUHYLRXVO\\HYDOXDWHG

DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI





'RHVWKHSURSRVHGDPHQGPHQWLQYROYHDVLJQLILFDQWUHGXFWLRQLQDPDUJLQ

RIVDIHW\\"

5HVSRQVH

1R

7KHSURSRVHGFKDQJHVFRQWLQXHWRSURYLGHWKHUHTXLUHGIXQFWLRQDOFDSDELOLW\\RIWKH

VDIHW\\ V\\VWHPV IRU SUHYLRXVO\\ HYDOXDWHG DFFLGHQWV DQG DQWLFLSDWHG RSHUDWLRQDO

RFFXUUHQFHV7KHSURSRVHGFKDQJHVGRQRWFKDQJHWKHIXQFWLRQRIWKHUHODWHG

V\\VWHPVQRUVLJQLILFDQWO\\DIIHFWWKHPDUJLQVSURYLGHGE\\WKHV\\VWHPV1RVDIHW\\

DQDO\\VLVRUGHVLJQEDVLVDFFHSWDQFHOLPLWFULWHULRQLVFKDOOHQJHGRUH[FHHGHGE\\

WKHUHTXHVWHGFKDQJHV

7KHUHIRUHWKHSURSRVHGDPHQGPHQWGRHVQRWLQYROYHDVLJQLILFDQWUHGXFWLRQLQD

PDUJLQRIVDIHW\\

%DVHGRQWKHDERYHLWLVFRQFOXGHGWKDWWKHSURSRVHGDPHQGPHQWGRHVQRWLQYROYHDVLJQLILFDQW

KD]DUGV FRQVLGHUDWLRQ XQGHU WKH VWDQGDUGV VHW IRUWK LQ  &)5  F  DQG DFFRUGLQJO\\ D

ILQGLQJRI³QRVLJQLILFDQWKD]DUGVFRQVLGHUDWLRQ'LVMXVWLILHG

 &RQFOXVLRQV

%DVHGRQWKHFRQVLGHUDWLRQVGLVFXVVHGDERYH  WKHUHLVUHDVRQDEOHDVVXUDQFHWKDWWKHKHDOWK

DQGVDIHW\\RIWKHSXEOLFZLOOQRWEHHQGDQJHUHGE\\RSHUDWLRQLQWKHSURSRVHGPDQQHU  VXFK

DFWLYLWLHVZLOOEHFRQGXFWHGLQFRPSOLDQFHZLWKWKH&RPPLVVLRQ¶VUHJXODWLRQVDQG  WKHLVVXDQFH

RIWKHDPHQGPHQWZLOOQRWEHLQLPLFDOWRWKHFRPPRQGHIHQVHDQGVHFXULW\\RUWRWKHKHDOWKDQG

VDIHW\\RIWKHSXEOLF7KHUHIRUHLWLVFRQFOXGHGWKDWWKHUHTXHVWHGDPHQGPHQWGRHVQRWLQYROYHD

VLJQLILFDQW KD]DUGV FRQVLGHUDWLRQ XQGHU WKH VWDQGDUGV VHW IRUWK LQ  &)5  F  DQG

DFFRUGLQJO\\DILQGLQJRI³QRVLJQLILFDQWKD]DUGVFRQVLGHUDWLRQ'LVMXVWLILHG





(19,5210(17$/&216,'(5$7,216

7KHSURSRVHGFKDQJHVWRWKH7HFKQLFDO6SHFLILFDWLRQV 76 DUHGHVFULEHGLQ6HFWLRQRIWKLV

(QFORVXUH

$UHYLHZKDVGHWHUPLQHGWKDWWKHSURSRVHGFKDQJHVUHTXLUHDQDPHQGPHQWWRWKH&2/$UHYLHZ

RI WKH DQWLFLSDWHG FRQVWUXFWLRQ DQG RSHUDWLRQDO HIIHFWV RI WKH UHTXHVWHG DPHQGPHQW KDV

GHWHUPLQHGWKDWWKHUHTXHVWHGDPHQGPHQWPHHWVWKHHOLJLELOLW\\FULWHULDIRUFDWHJRULFDOH[FOXVLRQ

VHWIRUWKLQ&)5 F  LQWKDW

(i)

There is no significant hazards consideration.

$V GRFXPHQWHG LQ 6HFWLRQ  6LJQLILFDQW +D]DUGV &RQVLGHUDWLRQ RI WKLV OLFHQVH

DPHQGPHQW UHTXHVW DQ HYDOXDWLRQ ZDV FRPSOHWHG WR GHWHUPLQH ZKHWKHU RU QRW D

VLJQLILFDQWKD]DUGVFRQVLGHUDWLRQLVLQYROYHGE\\IRFXVLQJRQWKHWKUHHVWDQGDUGVVHWIRUWK

LQ &)5 ³,VVXDQFH RI DPHQGPHQW'  7KH 6LJQLILFDQW +D]DUGV &RQVLGHUDWLRQ

HYDOXDWLRQGHWHUPLQHGWKDW  WKHSURSRVHGDPHQGPHQWGRHVQRWLQYROYHDVLJQLILFDQW

LQFUHDVHLQWKHSUREDELOLW\\RUFRQVHTXHQFHVRIDQDFFLGHQWSUHYLRXVO\\HYDOXDWHG  WKH

SURSRVHGDPHQGPHQWGRHVQRWFUHDWHWKHSRVVLELOLW\\RIDQHZRUGLIIHUHQWNLQGRIDFFLGHQW

IURP DQ\\ DFFLGHQW SUHYLRXVO\\ HYDOXDWHG DQG   WKH SURSRVHG DPHQGPHQW GRHV QRW

DRAFT 1'

(QFORVXUH

5HTXHVWIRU/LFHQVH$PHQGPHQW9DFXXP5HOLHI9DOYH7HFKQLFDO6SHFLILFDWLRQ&KDQJHV

/$5 

3DJHRI

LQYROYHDVLJQLILFDQWUHGXFWLRQLQDPDUJLQRIVDIHW\\7KHUHIRUHLWLVFRQFOXGHGWKDWWKH

SURSRVHG DPHQGPHQW GRHV QRW LQYROYH D VLJQLILFDQW KD]DUGV FRQVLGHUDWLRQ XQGHU WKH

VWDQGDUGV VHW IRUWK LQ &)5 F  DQG DFFRUGLQJO\\ D ILQGLQJ RI ³QR VLJQLILFDQW

KD]DUGVFRQVLGHUDWLRQ'LVMXVWLILHG

(ii)

There is no significant change in the types or significant increase in the amounts of any effluents that may be released offsite.

7KHSURSRVHGFKDQJHVDUHXQUHODWHGWRDQ\\DVSHFWRISODQWFRQVWUXFWLRQRURSHUDWLRQWKDW

ZRXOG LQWURGXFH DQ\\ FKDQJH WR HIIOXHQW W\\SHV HJ HIIOXHQWV FRQWDLQLQJ FKHPLFDOV RU

ELRFLGHVVDQLWDU\\V\\VWHPHIIOXHQWVDQGRWKHUHIIOXHQWV RUDIIHFWDQ\\SODQWUDGLRORJLFDORU

QRQUDGLRORJLFDOHIIOXHQWUHOHDVHTXDQWLWLHV)XUWKHUPRUHWKHSURSRVHGFKDQJHVGRQRW

DIIHFWDQ\\HIIOXHQWUHOHDVHSDWKRUGLPLQLVKWKHIXQFWLRQDOLW\\RIDQ\\GHVLJQRURSHUDWLRQDO

IHDWXUHVWKDWDUHFUHGLWHGZLWKFRQWUROOLQJWKHUHOHDVHRIHIIOXHQWVGXULQJSODQWRSHUDWLRQ

7KHUHIRUHLWLVFRQFOXGHGWKDWWKHSURSRVHGDPHQGPHQWGRHVQRWLQYROYHDVLJQLILFDQW

FKDQJHLQWKHW\\SHVRUDVLJQLILFDQWLQFUHDVHLQWKHDPRXQWVRIDQ\\HIIOXHQWVWKDWPD\\EH

UHOHDVHGRIIVLWH

(iii)

There is no significant increase in individual or cumulative occupational radiation exposure.

7KHSURSRVHGFKDQJHLQWKHUHTXHVWHGDPHQGPHQWGRHVQRWDIIHFWWKHVKLHOGLQJFDSDELOLW\\

RIRUDOWHUDQ\\ZDOOVIORRUVRURWKHUVWUXFWXUHVWKDWSURYLGHVKLHOGLQJ3ODQWUDGLDWLRQ

]RQHV DQG FRQWUROV XQGHU  &)5  SUHFOXGH D VLJQLILFDQW LQFUHDVH LQ RFFXSDWLRQDO

UDGLDWLRQH[SRVXUH7KHUHIRUHWKHSURSRVHGDPHQGPHQWGRHVQRWLQYROYHDVLJQLILFDQW

LQFUHDVHLQLQGLYLGXDORUFXPXODWLYHRFFXSDWLRQDOUDGLDWLRQH[SRVXUH

%DVHGRQWKHDERYHUHYLHZRIWKHSURSRVHGDPHQGPHQWLWKDVEHHQGHWHUPLQHGWKDWDQWLFLSDWHG

FRQVWUXFWLRQDQGRSHUDWLRQDOHIIHFWVRIWKHSURSRVHGDPHQGPHQWGRHVQRWLQYROYH L DVLJQLILFDQW

KD]DUGVFRQVLGHUDWLRQ LL DVLJQLILFDQWFKDQJHLQWKHW\\SHVRUVLJQLILFDQWLQFUHDVHLQWKHDPRXQWV

RIDQ\\HIIOXHQWVWKDWPD\\EHUHOHDVHGRIIVLWHRU LLL DVLJQLILFDQWLQFUHDVHLQWKHLQGLYLGXDORU

FXPXODWLYHRFFXSDWLRQDOUDGLDWLRQH[SRVXUH$FFRUGLQJO\\WKHSURSRVHGDPHQGPHQWPHHWVWKH

HOLJLELOLW\\FULWHULDIRUFDWHJRULFDOH[FOXVLRQVHWIRUWKLQ&)5 F  7KHUHIRUHSXUVXDQWWR

 &)5  E  QR HQYLURQPHQWDO LPSDFW VWDWHPHQW RU HQYLURQPHQWDO DVVHVVPHQW QHHG EH

SUHSDUHGLQFRQQHFWLRQZLWKWKHSURSRVHGDPHQGPHQW





5()(5(1&(6

1RQH

DRAFT







6RXWKHUQ1XFOHDU2SHUDWLQJ&RPSDQ\\





1'

(QFORVXUH





9RJWOH(OHFWULF*HQHUDWLQJ3ODQW 9(*3 8QLWVDQG





3URSRVHG&KDQJHVWR/LFHQVLQJ%DVLV'RFXPHQWV

/$5 











,QVHUWLRQV'HQRWHGE\\%OXH8QGHUOLQHDQG'HOHWLRQVE\\5HG6WULNHWKURXJK

2PLWWHGWH[WLVLGHQWLILHGE\\WKUHHDVWHULVNV     











(QFORVXUHFRQVLVWVRIILYHSDJHVLQFOXGLQJWKLVFRYHUSDJH

DRAFT 1'

(QFORVXUH

3URSRVHG&KDQJHVWR/LFHQVLQJ%DVLV'RFXPHQWV /$5 

3DJHRI

7HFKQLFDO6SHFLILFDWLRQ&RQWDLQPHQW,VRODWLRQ9DOYHV

/&2

(DFKFRQWDLQPHQWLVRODWLRQYDOYHVKDOOEH23(5$%/(H[FHSWIRUWKH

FRQWDLQPHQWLVRODWLRQYDOYHVDVVRFLDWHGZLWKFORVHGV\\VWHPVDQGIRU

YDFXXPUHOLHIYDOYHV

  

7HFKQLFDO6SHFLILFDWLRQ9DFXXP5HOLHI9DOYHV

/&2

7ZRYDFXXPUHOLHIIORZSDWKVFKHFNYDOYHVDQGWZRYDFXXPUHOLHI

LVRODWLRQYDOYHVVKDOOEH23(5$%/(

$1'

&RQWDLQPHQWLQVLGHWRRXWVLGHGLIIHUHQWLDODLUWHPSHUDWXUHVKDOOEH)

$33/,&$%,/,7<

02'(6DQG



02'(6DQGZLWKRXWDQRSHQFRQWDLQPHQWDLUIORZSDWKLQFKHVLQ

GLDPHWHU







127(

9DFXXPUHOLHIYDOYH23(5$%,/,7<IRUFORVLQJLVRQO\\UHTXLUHGLQ

02'(6DQG



$&7,216

127(

(QWHUDSSOLFDEOH&RQGLWLRQVDQG5HTXLUHG$FWLRQVRI/&2³&RQWDLQPHQW'ZKHQYDFXXP

UHOLHIYDOYHOHDNDJHUHVXOWVLQH[FHHGLQJWKHRYHUDOOFRQWDLQPHQWOHDNDJHUDWHDFFHSWDQFH

FULWHULD



DRAFT 1'

(QFORVXUH

3URSRVHG&KDQJHVWR/LFHQVLQJ%DVLV'RFXPHQWV /$5 

3DJHRI

$&7,216

&21',7,21

5(48,5('$&7,21

&203/(7,217,0(

$

2QHYDFXXPUHOLHIIORZ

SDWKFKHFNYDOYH

LQRSHUDEOHIRURSHQLQJ

$

5HVWRUHYDFXXPUHOLHI

IORZSDWKFKHFNYDOYHWR

23(5$%/(IRURSHQLQJ

VWDWXV

KRXUV

%

2QHYDFXXPUHOLHI

LVRODWLRQYDOYH

LQRSHUDEOHIRURSHQLQJ

%

5HVWRUHYDFXXPUHOLHI

LVRODWLRQYDOYHWR

23(5$%/(IRURSHQLQJ

VWDWXV

KRXUV

&

2QHRUPRUHYDFXXP

UHOLHIFKHFNYDOYHV

LQRSHUDEOHIRUFORVLQJ

25

2QHRUPRUHYDFXXP

UHOLHILVRODWLRQYDOYHV

LQRSHUDEOHIRUFORVLQJ

&

5HVWRUHDIIHFWHGYDOYH V 

WR23(5$%/(IRUFORVLQJ

VWDWXV

GD\\V

'

2QHRUPRUHYDFXXP

UHOLHIFKHFNYDOYHV

LQRSHUDEOHIRUFORVLQJ

$1'

2QHRUPRUHYDFXXP

UHOLHILVRODWLRQYDOYHV

LQRSHUDEOHIRUFORVLQJ

'







25



'

5HVWRUHERWKYDFXXP

UHOLHIFKHFNYDOYHVWR

23(5$%/(IRUFORVLQJ

VWDWXV





5HVWRUHERWKYDFXXP

UHOLHILVRODWLRQYDOYHVWR

23(5$%/(IRUFORVLQJ

VWDWXV

KRXU











KRXU

(%



&RQWDLQPHQWLQVLGHWR

RXWVLGHGLIIHUHQWLDODLU

WHPSHUDWXUH!)

(%

5HVWRUHFRQWDLQPHQW

LQVLGHWRRXWVLGH

GLIIHUHQWLDODLUWHPSHUDWXUH

WRZLWKLQOLPLW

KRXUV





25









(%

5HGXFHFRQWDLQPHQW

DYHUDJHWHPSHUDWXUH

)

KRXUV

DRAFT 1'

(QFORVXUH

3URSRVHG&KDQJHVWR/LFHQVLQJ%DVLV'RFXPHQWV /$5 

3DJHRI

$&7,216

&21',7,21

5(48,5('$&7,21

&203/(7,217,0(

)&



5HTXLUHG$FWLRQDQG

DVVRFLDWHG&RPSOHWLRQ

7LPHRI&RQGLWLRQ$%

&'RU(%QRWPHWLQ

02'(RU

25

%RWKYDFXXPUHOLHIIORZ

SDWKVLQRSHUDEOH7ZR

YDFXXPUHOLHIFKHFN

YDOYHVLQRSHUDEOHIRU

RSHQLQJLQ02'(

RU

25

7ZRYDFXXPUHOLHI

LVRODWLRQYDOYHV

LQRSHUDEOHIRURSHQLQJ

LQ02'(RU

)&

%HLQ02'(

KRXUV

$1'



)&





%HLQ02'(





KRXUV

'

5HTXLUHG$FWLRQDQG

DVVRFLDWHG&RPSOHWLRQ

7LPHRI&RQGLWLRQ$%

RU(%QRWPHWLQ

02'(RU

  • '

2SHQDFRQWDLQPHQWDLU

IORZSDWKLQFKHVLQ

GLDPHWHU

KRXUV



25



%RWKYDFXXPUHOLHIIORZ

SDWKVLQRSHUDEOH7ZR

YDFXXPUHOLHIFKHFN

YDOYHVLQRSHUDEOHIRU

RSHQLQJLQ02'(RU



25

7ZRYDFXXPUHOLHI

LVRODWLRQYDOYHV

LQRSHUDEOHIRURSHQLQJ

LQ02'(RU

DRAFT 1'

(QFORVXUH

3URSRVHG&KDQJHVWR/LFHQVLQJ%DVLV'RFXPHQWV /$5 

3DJHRI

6859(,//$1&(5(48,5(0(176 6859(,//$1&(

)5(48(1&<

65

9HULI\\FRQWDLQPHQWLQVLGHWRRXWVLGHGLIIHUHQWLDODLU

WHPSHUDWXUHLV)

KRXUV

65



127(6

 1RWUHTXLUHGWREHPHWIRUYDFXXPUHOLHIYDOYHV

RSHQGXULQJ6XUYHLOODQFHV

 1RWUHTXLUHGWREHPHWIRUYDFXXPUHOLHIYDOYHV

RSHQZKHQSHUIRUPLQJWKHLUYDFXXPUHOLHI

IXQFWLRQ







9HULI\\HDFKYDFXXPUHOLHILVRODWLRQYDOYHLVFORVHG

GD\\V

65

9HULI\\HDFKYDFXXPUHOLHIIORZSDWKYDOYHLV

23(5$%/(LQDFFRUGDQFHZLWKWKH,QVHUYLFH

7HVWLQJ3URJUDP

,QDFFRUGDQFH

ZLWKWKH,QVHUYLFH

7HVWLQJ3URJUDP

65

9HULI\\HDFKYDFXXPUHOLHILVRODWLRQYDOYHDFWXDWHVWR

UHOLHYHYDFXXPRQDQDFWXDORUVLPXODWHGVLJQDOV

PRQWKV

DRAFT







6RXWKHUQ1XFOHDU2SHUDWLQJ&RPSDQ\\





1'

(QFORVXUH





9RJWOH(OHFWULF*HQHUDWLQJ3ODQW 9(*3 8QLWVDQG





&RQIRUPLQJ&KDQJHVWRWKH7HFKQLFDO6SHFLILFDWLRQV%DVHV )RU,QIRUPDWLRQ2QO\\ 

/$5 











,QVHUWLRQV'HQRWHGE\\%OXH8QGHUOLQHDQG'HOHWLRQVE\\5HG6WULNHWKURXJK

2PLWWHGWH[WLVLGHQWLILHGE\\WKUHHDVWHULVNV     











(QFORVXUHFRQVLVWVRIHLJKWSDJHVLQFOXGLQJWKLVFRYHUSDJH 



DRAFT 1'

(QFORVXUH

&RQIRUPLQJ&KDQJHVWRWKH7HFKQLFDO6SHFLILFDWLRQV%DVHV )RU,QIRUPDWLRQ2QO\\ 

/$5 

3DJHRI

7HFKQLFDO6SHFLILFDWLRQV%DVHV%&RQWDLQPHQW,VRODWLRQ9DOYHV

  

%$6(6

/&2 FRQWLQXHG 

  



7KLV/&2SURYLGHVDVVXUDQFHWKDWWKHFRQWDLQPHQWLVRODWLRQYDOYHV

H[FHSWIRUWKHFORVHGV\\VWHPYDOYHVDQGYDFXXPUHOLHIYDOYHVDQGSXUJH

YDOYHVZLOOSHUIRUPWKHLUGHVLJQHGVDIHW\\IXQFWLRQV   



7KHFRQWDLQPHQWV\\VWHPYDFXXPUHOLHIYDOYHVSURYLGHFRQWDLQPHQW

LVRODWLRQEXWDUHDOVRUHTXLUHGWRRSHQWRPLWLJDWHDQHJDWLYHSUHVVXUH

HYHQWZLWKLQFRQWDLQPHQW7KHUHIRUHWKHYDFXXPUHOLHIYDOYHVDUHQRW

LQFOXGHGLQWKLV/&2VLQFHWKH\\DUHFRYHUHGLQ/&2³9DFXXP5HOLHI

9DOYHV'

  

DRAFT 1'

(QFORVXUH

&RQIRUPLQJ&KDQJHVWRWKH7HFKQLFDO6SHFLILFDWLRQV%DVHV )RU,QIRUPDWLRQ2QO\\ 

/$5 

3DJHRI

7HFKQLFDO6SHFLILFDWLRQV%DVHV%9DFXXP5HOLHI9DOYHV

  

%$&.*5281'

7KHSXUSRVHRIWKHYDFXXPUHOLHIOLQHVLVWRSURWHFWWKHFRQWDLQPHQW

YHVVHOIURPGDPDJHGXHWRDQHJDWLYHSUHVVXUH WKDWLVDORZHUSUHVVXUH

  LQFRPELQDWLRQZLWKORZRXWVLGHDPELHQWWHPSHUDWXUHZKLFK

UHGXFHVFRQWDLQPHQWWHPSHUDWXUH7KHYDFXXPUHOLHIYDOYHVKDYHDQ

DGGLWLRQDOIXQFWLRQWRSURYLGHFRQWDLQPHQWLVRODWLRQWRHVWDEOLVKD

FRQWDLQPHQWERXQGDU\\GXULQJSRVLWLYHSUHVVXUHDFFLGHQWFRQGLWLRQV

7KHFRQWDLQPHQWSUHVVXUHYHVVHOFRQWDLQVUHGXQGDQWUHOLHIGHYLFHVLQVLGH

DQGRXWVLGHFRQWDLQPHQWWZRFDSDFLW\\YDFXXPUHOLHIIORZSDWKVZLWK

DVKDUHGFRQWDLQPHQWSHQHWUDWLRQWKDWSURWHFWWKHFRQWDLQPHQWIURP

H[FHVVLYHH[WHUQDOSUHVVXUHORDGLQJ(DFKIORZSDWK7KHUHDUHWZR

RXWVLGHFRQWDLQPHQWFRQWDLQVDQRUPDOO\\FORVHGYDFXXPUHOLHILVRODWLRQ

YDOYHVZKLFKDUHPRWRURSHUDWHGYDOYHV 029V 7KHYDFXXPUHOLHI

LVRODWLRQYDOYHV029VUHFHLYHDQHQJLQHHUHGVDIHW\\IHDWXUHV (6) 

³RSHQ'VLJQDORQ&RQWDLQPHQW3UHVVXUH+/-/RZ7KHYDFXXPUHOLHI

VRODWLRQYDOYHV029VFORVHRQDQ(6)FRQWDLQPHQWLVRODWLRQVLJQDODV

ZHOODVRQ+LJKFRQWDLQPHQWUDGLRDFWLYLW\\(DFKIORZSDWKFRQWDLQVD

7KHUHDUHWZRQRUPDOO\\FORVHGVHOIDFWXDWHGFKHFNYDOYHVLQVLGH

FRQWDLQPHQWWKDWRSHQVRQDQHJDWLYHGLIIHUHQWLDOSUHVVXUHRISVL$

YDFXXPUHOLHIIORZSDWKFRQVLVWVRIRQHLVRODWLRQYDOYH029DQGRQH

FKHFNYDOYHDQGWKHVKDUHGFRQWDLQPHQWSHQHWUDWLRQ



7KHSDUDOOHOYDFXXPUHOLHILVRODWLRQYDOYHV029VDUHLQWHUORFNHGZLWKWKH

LQFKFRQWDLQPHQWSXUJHGLVFKDUJHLVRODWLRQYDOYHLQVLGHFRQWDLQPHQW

9)63/9ZKLFKVKDUHVWKHFRQWDLQPHQWSHQHWUDWLRQ7KHYDFXXP

UHOLHILVRODWLRQYDOYHV029VDUHEORFNHGIURPRSHQLQJLI9)63/9LV

QRWFORVHG,I9)63/9LVQRWFORVHGWKHQWKHYDFXXPUHOLHILVRODWLRQ

YDOYHV029VZLOODXWRPDWLFDOO\\FORVHWRGLUHFW9)6SXUJHH[KDXVWWKURXJK

WKHQRUPDO9)6GLVFKDUJHIORZSDWK+RZHYHULIYDFXXPUHOLHIDFWXDWLRQ

LVUHTXLUHGWKHYDFXXPUHOLHILVRODWLRQYDOYH029DFWXDWLRQVLJQDO

RYHUULGHVWKHFORVLQJLQWHUORFNZLWK9)63/9WRDOORZWKHYDFXXP

UHOLHILVRODWLRQYDOYHV029VWRRSHQHQVXULQJWKDWWKHYDFXXPUHOLHI

SURWHFWLRQDFWXDWHV 5HI 



$33/,&$%/(

6$)(7<

$1$/<6(6

  



7KHYDFXXPUHOLHIYDOYHVPXVWDOVRSHUIRUPWKHFRQWDLQPHQWLVRODWLRQ

IXQFWLRQ DVUHTXLUHGE\\/&2³&RQWDLQPHQW,VRODWLRQ9DOYHV' 

GXULQJDFRQWDLQPHQWKLJKSUHVVXUHHYHQW)RUWKLVUHDVRQWKHV\\VWHPLV

  

DRAFT 1'

(QFORVXUH

&RQIRUPLQJ&KDQJHVWRWKH7HFKQLFDO6SHFLILFDWLRQV%DVHV )RU,QIRUPDWLRQ2QO\\ 

/$5 

3DJHRI

  

/&2

7KH/&2HVWDEOLVKHVWKHPD[LPXPFRQWDLQPHQWWHPSHUDWXUHLQLWLDO

FRQGLWLRQDQGWKHPLQLPXPHTXLSPHQWUHTXLUHGWRDFFRPSOLVKWKHYDFXXP

UHOLHIIXQFWLRQIROORZLQJH[FHVVLYHFRQWDLQPHQWFRROLQJHYHQWV 5HI 

7KLV/&2DOVRDGGUHVVHVWKHPLQLPXPHTXLSPHQWUHTXLUHGWRSHUIRUPWKH

FRQWDLQPHQWLVRODWLRQIXQFWLRQRIWKHYDFXXPUHOLHIYDOYHV7ZR

YDFXXPUHOLHIIORZSDWKVDUHUHTXLUHGWREH23(5$%/(WRHQVXUHWKDWDW

OHDVWRQHLVDYDLODEOHDVVXPLQJRQHRUERWKYDOYHVLQWKHRWKHUIORZSDWK

IDLOWRRSHQ$YDFXXPUHOLHIIORZSDWKLV23(5$%/(LIWKH029RSHQVRQ

DQ(6)RSHQVLJQDODQGWKHVHOIDFWXDWHGFKHFNYDOYHVRSHQRQD

QHJDWLYHGLIIHUHQWLDOSUHVVXUHRISVL



7KHYDFXXPUHOLHIFKHFNYDOYHVDUHORFDWHGLQLQGHSHQGHQWSDUDOOHOSDWKV

LQVLGHFRQWDLQPHQWDQGWKHYDFXXPUHOLHILVRODWLRQYDOYHVDUHORFDWHGLQ

LQGHSHQGHQWSDUDOOHOSDWKVRXWVLGHFRQWDLQPHQWWKH\\DUHFRQQHFWHGE\\D

FRPPRQFRQWDLQPHQWSHQHWUDWLRQ7KHUHIRUHWZRYDFXXPUHOLHIFKHFN

YDOYHVDQGWZRYDFXXPUHOLHILVRODWLRQYDOYHVDUHUHTXLUHGWREH

23(5$%/(WRHQVXUHWKDWDWOHDVWRQHYDFXXPUHOLHISDWKLVDYDLODEOHZLWK

WKHIDLOXUHWRRSHQRIRQHFKHFNYDOYHDQGRURQHLVRODWLRQYDOYHDQGWR

HQVXUHWKDWWKHUHDUHWZREDUULHUVIRUFRQWDLQPHQWLVRODWLRQ7REH

FRQVLGHUHG23(5$%/(IRUFORVLQJDYDFXXPUHOLHIFKHFNYDOYHPXVW

FORVHZLWKDGLIIHUHQWLDOSUHVVXUHOHVVWKDQRUHTXDOWRSVLRXWVLGH

DWPRVSKHUHWRFRQWDLQPHQWSUHVVXUH7REHFRQVLGHUHG23(5$%/(IRU

RSHQLQJDYDFXXPUHOLHILVRODWLRQYDOYHPXVWEHFDSDEOHRIRSHQLQJRQDQ

(6)RSHQVLJQDODQGWREHFRQVLGHUHG23(5$%/(IRUFORVLQJWKH

LVRODWLRQYDOYHPXVWEHFDSDEOHRIFORVLQJRQDQ(6)FORVXUHVLJQDO

  

$33/,&$%,/,7<

  



7KHUHIRUHWKHYDFXXPUHOLHIYDOYHVIORZSDWKVDUHUHTXLUHGWREH

23(5$%/(IRURSHQLQJLQ02'(6WKURXJKDQGLQ02'(6DQG

ZLWKRXWDQRSHQFRQWDLQPHQWDLUIORZSDWKLQFKHVLQGLDPHWHU:LWKD

LQFKGLDPHWHURUHTXLYDOHQWFRQWDLQPHQWDLUIORZSDWKWKHYDFXXPUHOLHI

IXQFWLRQLVQRWQHHGHGWRPLWLJDWHDORZSUHVVXUHHYHQW



7KH$SSOLFDELOLW\\LVPRGLILHGE\\D1RWHWKDWWKHYDFXXPUHOLHIYDOYH

23(5$%,/,7<IRUFORVLQJLVRQO\\UHTXLUHGLQ02'(6DQG,Q

02'(6DQGD'%$FRXOGFDXVHDUHOHDVHRIUDGLRDFWLYH

PDWHULDOWRFRQWDLQPHQW,Q02'(6DQGWKHSUREDELOLW\\DQG

FRQVHTXHQFHVRIWKHVHHYHQWVDUHUHGXFHGGXHWRWKHSUHVVXUHDQG

WHPSHUDWXUHOLPLWDWLRQVRIWKHVH02'(67KHUHIRUHWKHYDFXXPUHOLHI

YDOYH23(5$%,/,7<IRUFORVLQJLVRQO\\UHTXLUHGLQ02'(6DQG

WRSUHYHQWOHDNDJHRIUDGLRDFWLYHPDWHULDOIURPFRQWDLQPHQWGXULQJ

SRVLWLYHSUHVVXUHDFFLGHQWFRQGLWLRQV+RZHYHUFRQWDLQPHQWFORVXUH

FDSDELOLW\\LVUHTXLUHGLQ02'(6DQG 7KHUHTXLUHPHQWVIRU

DRAFT 1'

(QFORVXUH

&RQIRUPLQJ&KDQJHVWRWKH7HFKQLFDO6SHFLILFDWLRQV%DVHV )RU,QIRUPDWLRQ2QO\\ 

/$5 

3DJHRI

FRQWDLQPHQWLVRODWLRQYDOYHVLQFOXGLQJWKHYDFXXPUHOLHIYDOYHVGXULQJ

02'(6DQGDUHDGGUHVVHGLQ/&2³&RQWDLQPHQW

3HQHWUDWLRQV'



$&7,216

7KH$FWLRQVDUHPRGLILHGE\\D1RWHWKDWGLUHFWVHQWU\\LQWRWKHDSSOLFDEOH

&RQGLWLRQVDQG5HTXLUHG$FWLRQVRI/&2³&RQWDLQPHQW'LQWKH

HYHQWWKDWYDFXXPUHOLHIYDOYHOHDNDJHUHVXOWVLQH[FHHGLQJWKHRYHUDOO

FRQWDLQPHQWOHDNDJHUDWHDFFHSWDQFHFULWHULD



$

LWK:KHQRQHRIWKHUHTXLUHGYDFXXPUHOLHIFKHFNYDOYHIORZSDWKVLV

LQRSHUDEOHIRURSHQLQJWKHLQRSHUDEOHYDOYHIORZSDWKPXVWEHUHVWRUHGWR

23(5$%/(IRURSHQLQJVWDWXVZLWKLQKRXUV,WLVDFFHSWDEOHWRHQWHU

&RQGLWLRQ$DQG%FRQFXUUHQWO\\7KHYDFXXPUHOLHIIXQFWLRQLVPDLQWDLQHG

ZLWKDWOHDVWRQHFKHFNYDOYHDQGRQHLVRODWLRQYDOYH23(5$%/(ZKLFK

LVDVVXUHGSURYLGHG&RQGLWLRQ)RU*LVQRWHQWHUHGIRUWZRYDFXXPUHOLHI

FKHFNYDOYHVRUWZRYDFXXPUHOLHILVRODWLRQYDOYHVLQRSHUDEOHIRURSHQLQJ

7KHVSHFLILHG&RPSOHWLRQ7LPHWLPHSHULRGLVFRQVLVWHQWZLWKRWKHU/&2V

IRUWKHORVVRIRQHWUDLQRIDV\\VWHPUHTXLUHGWRPLWLJDWHWKH

FRQVHTXHQFHVRID/2&$RURWKHU'%$



%

LWKRQHYDFXXPUHOLHILVRODWLRQYDOYHLQRSHUDEOHIRURSHQLQJWKH

LQRSHUDEOHYDOYHPXVWEHUHVWRUHGWR23(5$%/(IRURSHQLQJVWDWXV

ZLWKLQKRXUV3URYLGHG&RQGLWLRQ)RU*LVQRWHQWHUHGIRUWZRYDFXXP

UHOLHIFKHFNYDOYHVRUWZRYDFXXPUHOLHILVRODWLRQYDOYHVLQRSHUDEOHIRU

RSHQLQJWKHQWKHYDFXXPUHOLHIIXQFWLRQLVPDLQWDLQHGZLWKDWOHDVWRQH

FKHFNYDOYHDQGRQHLVRODWLRQYDOYH LHLWLVDFFHSWDEOHWRHQWHU

&RQGLWLRQV$DQG%FRQFXUUHQWO\\ 7KH&RPSOHWLRQ7LPHSHULRGLV

FRQVLVWHQWZLWKRWKHU/&2VIRUWKHORVVRIRQHWUDLQRIDV\\VWHPUHTXLUHG

WRPLWLJDWHWKHFRQVHTXHQFHVRID/2&$RURWKHU'%$



&

LWKRQHRUPRUHYDFXXPUHOLHIFKHFNYDOYH V LQRSHUDEOHIRUFORVLQJRU

ZLWKRQHRUPRUHYDFXXPUHOLHILVRODWLRQYDOYHVLQRSHUDEOHIRUFORVLQJ

LQFOXGLQJHLWKHUWZRYDFXXPUHOLHIFKHFNYDOYHVLQRSHUDEOHIRUFORVLQJRU

WZRYDFXXPUHOLHILVRODWLRQYDOYHVLQRSHUDEOHIRUFORVLQJ SURYLGHG

&RQGLWLRQ'LVQRWHQWHUHGWKHSHQHWUDWLRQKDVQRWORVWLVRODWLRQ

FDSDELOLW\\

DRAFT 1'

(QFORVXUH

&RQIRUPLQJ&KDQJHVWRWKH7HFKQLFDO6SHFLILFDWLRQV%DVHV )RU,QIRUPDWLRQ2QO\\ 

/$5 

3DJHRI



7KH&RPSOHWLRQ7LPHWRUHVWRUHWKHYDOYHWR23(5$%/(IRUFORVLQJ

VWDWXVLQGD\\VKDVEHHQVKRZQWREHDFFHSWDEOHEDVHGRQSUREDELOLW\\

ULVNDVVHVVPHQWFRQVLGHULQJWKHLPSRUWDQFHRIVXSSRUWLQJFRQWDLQPHQW

23(5$%,/,7<GXULQJ02'(6ZLWKWKHDYDLODELOLW\\RIRQH

EDUULHUIRUFRQWDLQPHQWLVRODWLRQZKLOHDOVRPDLQWDLQLQJWKHFDSDELOLW\\IRU

YDFXXPUHOLHI



'

LWKRQHRUPRUHYDFXXPUHOLHIFKHFNYDOYHVDQGRQHRUPRUHYDFXXP

UHOLHILVRODWLRQYDOYHVLQRSHUDEOHIRUFORVLQJHLWKHUERWKYDFXXPUHOLHI

FKHFNYDOYHVRUERWKYDFXXPUHOLHILVRODWLRQYDOYHVDUHWREHUHVWRUHGWR

23(5$%/(IRUFORVLQJVWDWXVZLWKLQKRXUWRUHVWRUHWKHFDSDELOLW\\WR

LVRODWHWKHFRQWDLQPHQWSHQHWUDWLRQ:LWKRQHFKHFNYDOYHDQGRQH

LVRODWLRQYDOYHLQRSHUDEOHIRUFORVLQJWKHFRQWDLQPHQWLVRODWLRQFDSDELOLW\\

LVORVWDQGDUHOHDVHSDWKUHPDLQVRSHQ7RDGGUHVVWKLVHLWKHUERWK

YDFXXPUHOLHIFKHFNYDOYHVRUERWKYDFXXPUHOLHILVRODWLRQYDOYHVQHHGWR

EHUHVWRUHGWR23(5$%/(IRUFORVLQJVWDWXVWRSURYLGHDFRQWDLQPHQW

LVRODWLRQEDUULHU7KHKRXU&RPSOHWLRQ7LPHLVFRQVLVWHQWZLWK$FWLRQ%

RI/&2



(DQG(%DQG%



,IWKHFRQWDLQPHQWLQVLGHWRRXWVLGHGLIIHUHQWLDODLUWHPSHUDWXUHLV!)

WKHQWKHGLIIHUHQWLDODLUWHPSHUDWXUHVKDOOEHUHVWRUHGWRZLWKLQWKHOLPLW

ZLWKLQKRXUV7KHKRXU&RPSOHWLRQ7LPHLVUHDVRQDEOHFRQVLGHULQJ

WKDWOLPLWLVEDVHGRQDZRUVWFDVHFRQGLWLRQDQGWKHWLPHQHHGHGWR

UHGXFHWKHFRQWDLQPHQWWHPSHUDWXUHZKLOHFRQWUROOLQJSUHVVXUHZLWKLQ

OLPLWVRI/&2&RQWDLQPHQW3UHVVXUH



,IWKHGLIIHUHQWLDOWHPSHUDWXUHFDQQRWEHUHVWRUHG5HTXLUHG$FWLRQ(%

SURYLGHVDQDOWHUQDWHUHTXLUHPHQW5HGXFWLRQRIWKHFRQWDLQPHQWDYHUDJH

WHPSHUDWXUHWR)SURYLGHVDQLQLWLDOFRQGLWLRQIRUH[FHVVLYHFRROLQJ

HYHQWVWKDWHQVXUHVWKHYDFXXPUHOLHIV\\VWHPFDSDFLW\\LVVXIILFLHQW

5HI 



)DQG)&&DQG'



,IWKH5HTXLUHG$FWLRQDQGDVVRFLDWHG&RPSOHWLRQ7LPHRI&RQGLWLRQV$

%&'RU($RU%DUHQRWPHWLQ02'(RURUWZRYDFXXP

UHOLHIFKHFNYDOYHVDUHLQRSHUDEOHIRURSHQLQJLQ02'(RURU

WZRYDFXXPUHOLHILVRODWLRQYDOYHVDUHLQRSHUDEOHIRURSHQLQJERWK

YDFXXPUHOLHIIORZSDWKVDUHLQRSHUDEOHLQ02'(RUWKHSODQW

PXVWEHEURXJKWWRDWOHDVW02'(ZLWKLQKRXUVDQGWR02'(ZLWKLQ

KRXUV7KHDOORZHG&RPSOHWLRQ7LPHVDUHUHDVRQDEOHEDVHGRQ

RSHUDWLQJH[SHULHQFHWRUHDFKWKHUHTXLUHGSODQWFRQGLWLRQVIURPIXOO

SRZHUFRQGLWLRQVLQDQRUGHUO\\PDQQHUDQGZLWKRXWFKDOOHQJLQJSODQW

DRAFT 1'

(QFORVXUH

&RQIRUPLQJ&KDQJHVWRWKH7HFKQLFDO6SHFLILFDWLRQV%DVHV )RU,QIRUPDWLRQ2QO\\ 

/$5 

3DJHRI

V\\VWHPV



  • 

2QFHLQ02'(RU5HTXLUHG$FWLRQ*'UHTXLUHVWKDWD

FRQWDLQPHQWDLUIORZSDWKLQFKHVLQGLDPHWHUVKDOOEHRSHQHGZLWKLQ

KRXUVLIWKH5HTXLUHG$FWLRQDQGDVVRFLDWHG&RPSOHWLRQ7LPHRI

&RQGLWLRQ$%RU(LVQRWPHWRULIWZRYDFXXPUHOLHIFKHFNYDOYHVDUH

LQRSHUDEOHIRURSHQLQJRULIWZRYDFXXPUHOLHILVRODWLRQYDOYHVDUH

LQRSHUDEOHIRURSHQLQJ$Q\\IORZSDWK RUSDWKV ZLWKDQDUHDHTXLYDOHQW

WRLQFKHVLQGLDPHWHULVDGHTXDWHWRSURYLGHWKHQHFHVVDU\\DLUIORZIRU

FRQWDLQPHQWYDFXXPUHOLHI

  

6859(,//$1&(

5(48,5(0(176

  



65

(DFKYDFXXPUHOLHILVRODWLRQYDOYHPXVWEHYHULILHGWREHFORVHGHYHU\\

GD\\V7KLV65DVVXUHVWKDWWKHYDFXXPUHOLHILVRODWLRQYDOYHVDUH

FORVHGDVUHTXLUHGRULIRSHQWKHYDOYHVDUHRSHQIRUDQDOORZDEOH

UHDVRQ7KHYDFXXPUHOLHILVRODWLRQYDOYHVDUHQRUPDOO\\FORVHG7KH

)UHTXHQF\\RIGD\\VLVDSSURSULDWHFRQVLGHULQJWKHYDOYHVVKRXOGRQO\\EH

RSHQHGWRUHOLHYHYDFXXPRUPDQXDOO\\RSHQHGWRSHUIRUP6XUYHLOODQFHV

DQGWKHUHIRUHWKHSUREDELOLW\\RIWKHYDOYHPLVDOLJQPHQWLVORZ



65LVPRGLILHGE\\WZR1RWHV1RWHVWDWHVWKDW65LVQRW

UHTXLUHGWREHPHWIRUYDFXXPUHOLHIYDOYHVWKDWDUHRSHQGXULQJ

6XUYHLOODQFHV6XUYHLOODQFHVZKLFKRSHQWKHYDFXXPUHOLHILVRODWLRQYDOYHV

DUHSHUIRUPHGLQIUHTXHQWO\\DQGWKHYDOYHVZLOORQO\\EHRSHQIRUDOLPLWHG

SHULRGRIWLPH1RWHVWDWHVWKDW65LVQRWUHTXLUHGWREHPHWIRU

YDFXXPUHOLHIYDOYHVSHUIRUPLQJWKHLUYDFXXPUHOLHIIXQFWLRQ,IYDFXXP

UHOLHILVUHTXLUHGWKHYDOYHVRSHQWRSHUIRUPWKHLUVDIHW\\IXQFWLRQWR

PDLQWDLQWKHLQWHJULW\\RIWKHFRQWDLQPHQWYHVVHO$LUZLOOIORZLQWR

FRQWDLQPHQWIURPWKHDWPRVSKHUHGXHWRWKHGLIIHUHQWLDOSUHVVXUHZKLFK

ZLOOSUHYHQWUDGLRORJLFDOUHOHDVHIURPFRQWDLQPHQWGXULQJYDFXXPUHOLHI



65

9DFXXPUHOLHIYDOYHVDUHWHVWHGWREH23(5$%/(IRURSHQLQJDQG

23(5$%/(IRUFORVLQJ7KLV65FLWHVWKH,QVHUYLFH7HVWLQJ3URJUDP

ZKLFKHVWDEOLVKHVWKHUHTXLUHPHQWWKDWLQVHUYLFHWHVWLQJRIWKH$60(&RGH

&ODVVDQGYDOYHVVKDOOEHSHUIRUPHGLQDFFRUGDQFHZLWKWKH$60(

20&RGH 5HI 7KHUHIRUH65)UHTXHQF\\LVJRYHUQHGE\\WKH,QVHUYLFH

7HVWLQJ3URJUDP

DRAFT 1'

(QFORVXUH

&RQIRUPLQJ&KDQJHVWRWKH7HFKQLFDO6SHFLILFDWLRQV%DVHV )RU,QIRUPDWLRQ2QO\\ 

/$5 

3DJHRI



65

7KLV65HQVXUHVWKDWHDFKYDFXXPUHOLHILVRODWLRQPRWRURSHUDWHGYDOYH

ZLOODFWXDWHWRWKHRSHQSRVLWLRQRQDQDFWXDORUVLPXODWHGDFWXDWLRQVLJQDO

DQGZLOODFWXDWHWRWKHFORVHGSRVLWLRQRQDQDFWXDORUVLPXODWHGDFWXDWLRQ

VLJQDO7KHDFWXDORUVLPXODWHGVLJQDOLVSURFHVVHGWKURXJKWKH

FRPSRQHQWLQWHUIDFHPRGXOHWRYHULI\\WKHFRQWLQXLW\\EHWZHHQWKHRXWSXWRI

WKHFRPSRQHQWLQWHUIDFHPRGXOHDQGWKHYDOYHV7KH)UHTXHQF\\RI

PRQWKVLVEDVHGRQWKHQHHGWRSHUIRUPWKLVVXUYHLOODQFHGXULQJ

SHULRGVLQZKLFKWKHSODQWLVVKXWGRZQIRUUHIXHOLQJWRSUHYHQWDQ\\XSVHWV

RISODQWRSHUDWLRQV