Forwards Rept of Steam Tube Generator Tube Insp for Facility Third Refueling Outage,Inservice Insp Completed on 870606, Per Tech Specs 4.4.5.5b & 6.9.2.Listed Quantity of Tubes Inspected from Inlet Side of Steam Generators
ML20155J730
Person / Time
Site: Mcguire
Issue date: 06/06/1988
From: Tucker H
DUKE POWER CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8806210014
Download: ML20155J730 (11)


Text

i 9

Duxe POWER COMPANY P.O. DOX 33100 CitARLOTTE. N.C. 28242 T E LE P,10?tE IIAL B. TIJCKER (704) 073-4531 VICE PRESGSNT mmsAs Paoot.rrion June 6, 1988 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-

Subject:

McGuire Nuclear Station, Unit 2 Docket No. 50-370 Steam Generator ISI Gentlemen:

Pursuant to McGuire Nuclear Station Technical Specifications 4.4.5.5b and 6.9.2, attached is a report of the steam generator tube inspection for McGuire Unit 2, third refueling outage, ISI completed on June 6,1987.

Re following quantity of tubes were inspected from the inlet side of the steam generators:

TUBES INSPECTED S/G Full Length Partial Length A

325 4559 B

356 4560 C

363 4558 D

353 4557 The following information is submitted concerning tub e indications of imperfections.

(The attached lists identify the tubes with imperfections, their location and their size.)

Steam Generator Attachment A

1 B

2 C

3 D

4 The following quantities of tubes were removed from service.

(ne tubes are identified in the attachments.)

Steam Generator Numbend Tube Plugged Attachment A

35 5

B 42 6

C 30 7

D 34 8

(O 8806210014 880606 PDR ADOCK 05000370 11 Q

DCD

s Docusant Control Dssk June 6, 1988 Page 2 If further information is needes, please contact use through normal licensing channels.

Very truly yours,

/,

( #

e dal B. Tucker JBD/269/ bhp Attachment ec:

Mr. Darl Hood U.S. Nuclear Regulatory Commission Of fice of Nuclear Reactor Regulation Washington, DC 20555 Dr. J. Nelson Grace Regional Administrator Region II U.S. Nuclear Regulatory Commission 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 t/Mr. W. T. Orders NRC Resident Inspector McGuire Nuclear Station i

l t,,.

i

'em DWE TUBM(TIC MR. i.e)H+H4 $Uyten JUH 4, tsee to tes M ++++++ BABC00( l WILCOI CO. m*4 Paga l Plantt McGUIRE UNIT 2 Stocm G:nsretor: A Outage 5/87 RFO QUERY: ATTACHMENT 1 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE INDICATION VALUE VOLTS ELEVATION INCHES


l) 56 % TW 0.00 HTS-P

+10.60 2

G2 5/87 RFO ID (genera 2

63 5/87 RFO ID (general) 75 % TW 0.00 HTS-P

+20.20 3

54 5/87 RFO ID (general) 57 % TW 0.00 HTS-P

+12.90 3

57 5/87 RFO ID (general) 64 % TW 0.00 HTS-P

+ 8.50 S

60 5/87 RFO ID (general) 86 % TW 0.00 HTS-P

+20.40 5/87 RFO ID (general) 97 % TW 0.00 HTS-P

+10.60 5/87 RFO ID (general) 54 % TW 0.00 HTS-P

+17.50 3

61 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+12.70 5/87 RFO ID (general) 81 % TW 0.00 HTS-P

+ 0.70 3

62 5/87 RFO ID (general) 62 % TW 0.00 HTS-P

+14.70 4

61 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+18.60

(

72 % TW 0.00 HTS-P

+19.90 (general) 4 68 5/87 RFO ID general)

G2 % TW 0.00 HTS-P

+17.10 5

54 5/87 RFO ID 5

62 5/87 RFO ID (general) 43 % TW 0.00 HTS-P

+12.50 6

21 5/87 RFO ID (general) 92 % TW 0.00 HTS-P

+ 8.20

(

86 % TW 0.00 HTS-P

+18.80 (general) 6 35 5/87 RFO ID general) 88 % TW 0.00 HTS-P

+14.10 6

56 5/87 RFO ID 5/87 RFO ID (general) 48 % TW 0.00 HTS-P

+19.00 8

62 5/87 RFO ID (general) 75 % TW 0.00 HTS-P

+17.40 9 105 5/87 RFO ID (general) 82 % TW 0.00 HTS-P

+ 7.30 10 42 5/87 RFO ID (general) 59 % TW 0.00 HTS-P

+16.30 10 50 5/87 RFO ID (general) 42 % TW 0.00 HTS-P

+20.00 5/87 RFO ID (general) 45 % TW 0.00 HTS-P

+11.30 5/87 RFO ID (general) 42 % TW 0.00 HTS-P

+17.30 11 44 5/87 RFO ID (general) 86 % TW 0.00 HTS-P

+15.00 12 35 5/87 RFO ID (general) 51 % TW 0.00 HTS-P

+ 4.30 12 44 5/87 RFO ID (general) 48 % TW 0.00 HTS-P

+19.90 12 63 5/87 RFO ID (general) 48 % TW 0.00 HTS-P

+19.30 15 30 5/87 RFO ID (general) 78 % TW 0.00 HTS-P

+20.20 15 57 5/87 RFO ID (general) 67 % TW 0.00 HTS-P

+15.00 15 68 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+20.10 16 29 5/87 RFO ID (general) 51 % TW 0.00 HTS-P

+13.20 16 31 5/87 RFO ID (general) 73 % TW 0.00 HTS-P

+20.10 16 33 5/87 RFO ID (general) 54 % TW 0.00 HTS-P

+11.20 5/87 RFO ID (general) 73 % TW 0.00 HTS-P

+ 9.30 17 24 5/87 RFO ID (general) 43 % TW 0.00 HTS-P

+ 8.80 5/87 RFO ID (general) 59 % TW 0.00 HTS-P

+12.20 17 25 5/87 RFO ID ( gener al )

59 % TW 0.00 HTS-S

- 6.80 17 34 5/87 RFO ID (general' 84 % TW 0.00 HTS-P

+19.20 18 13 5/87 RFO ID (gencral) 54 % TW 0.00 HTS-P

+17.10 18 15 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+ 5.40 18 18 5/87 RFO ID (general) 70 % TW 0.00 HTS-P

+ 0.60 18 24 5/87 RFO ID (general) 46 % TW 0.00 HTS-P

+19.00 18 27 5/87 RFO ID (general) 59 % TW 0.00 HTS-P

+19.10 18 29 5/87 RFO ID (general) 51 % TW 0.00 HTS-?

+20.20 5/87 RFO ID (general) 62 % TW 0.00 HTS-P

+16.20 18 33 5/87 RFO ID (general) 46 % TW 0.00 HTS-P

+14.10

(

59 % TW 0.00 HTS-P

+11.40 (general) 5/87 RFO ID general) 43 % TW 0.00 HTS-P

+ 8.30 19 21 5/87 RFO ID 19 33.5/87 RFO ID (genetwl) 62 % TW 0.00 HTS-P

+20,20 19 70 5/87 RFO ID (general) 91 % TW 0.00 HTS-P

+20.20 23 60 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+16.90 27 19 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+16.90 27 39 5/87 RFO ID (general) 68 % TW 0.00 HTS-P

+ 2.40 27 48 5/87 RFO ID (general) 57 % TW 0.00 HTS-P

+19.90 27 49 5/87 RFO ID (general) 57 % TW 0.00 HTS-P

+17.20 31 6 '. 5/87 RFO ID (general) 54 % TW 0.00 HTS-P

+16.20 32 40 5/87 RFO ID (general) 46 % TW 0.00 HTS-P

+20.10 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+19.10 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+16.00 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+15.00 34 21 5/87 RFO ID (general) 64 % TW 0.00 HTS-P

+20.80 34 74 5/87 RFO ID (general) 72 % TW 0.00 HTS-P

+19.80 35 45 5/87 RFO ID (general) 72 % TW 0.00 HTS-P

+18.90 35 54 5/87 RFO ID (general) 46 % TW 0.00 HTS-P

+16.00 37 43 5/87 RFO ID (general) 62 % TW 0.00 HTS-P

+20.20 38 41 5/87 RFO ID (general) 48 % TW 0.00 HTS-P

+ 2.70

  • DHM6 E TIM 51(IM) (WR. 3 0)lM+M Sof Ut94Y JW!E 4,

litt telli PM GM*H M 4 WILCDI CO, eM+M Pags h(

Plantt McGUIRE UNIT 2 Stocm G:nsrctor: A Outage:

5/87.FO OUERY: ATTACHMENT 1 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE INDICATION VALUE VOLTS ELEVATION INCHES

--- --- ---------- --------------- -70 % TW 0.00 HTS-P

+ 9.20 38 45 5/87 RFO ID (general) 38 61 5/87 RFO ID (general) 57 % TW 0.00 HTS-P

+19.20 42 68 5/87 RFO ID (general) 57 % TW 0.00 HTS-P

+12.20 43 45 5/87 RFO ID (general) 57 % TW 0.00 HTS-P

+de.20 5/87 RFO ID (general) 89 % TW 0.00 HTS-P

+19.10

(

59 % TW 0.00 HTS-P

+17.20 (general) 5/87 RFO ID 62 % TW 0.00 HTS-P

+14.20 (general) general) 80 % TW 0.00 HTS-P

+12.40 5/87 RFO ID 5/S7 RFO ID 5/87 RFO ID (general) 75 % TW 0.00 HTS-P

+ 8.50 5/87 RFO ID (general) 59 % TW 0.00 HTS-P

+ 6.50 5/87 RFO ID (general) 45 % TW 0.00 HTS-P

+ 5.60 43 59 5/87 RFO ID (general) 89 % TW 0.00 HTS-P

+20.20' 5/87 RFO ID (general) 91 % TW 0.00 HTS-P

+19.20 5/87 RFO ID (general) 67 % TW 0.00 HTS-P

+17.30 5/87 RFO ID (general) 95 % TW 0.00 HTS-P

+15.30 43 68 5/87 RFO ID (general) 58 % TW 0.00 HTS-P

+13.20 44 37 5/87 RFO ID (general) 37 % TW 0.00 HTS-P

+19.10 44 63 5/87 RFO ID (general) 59 % TW 0.00 HTS-P

+ 7.70

=

62 TOTAL TUBES FOUND

=

85 TOTAL INDICATIONS FOUND TOTAL TUBES IN INPUT FILE =

4674 4559 TOTAL TUBES INSPECTED

=

l

' 4HM* 00E TLSM(TIO MR. 3.eluun Satumt Just i, ases assin m H+4H 8ASC00( 8 Wit.COI CO. um pagg { o4 Plant: McGUIRE UNIT 2 Stocm G:nSector: 8 Outage:

5/87 RFC OUERY: ATTACHMENT 2 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE INDICATION VALUE VOLTS ELEVATION INCHES

--- --- ---------- ---- ---------- ------TW 0.00 HTS-P

+19.90 2

58 5/87 RFO ID (general) 74 %

2 81 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+20.10 2

82 5/87 RFO ID (general) 83 % TW 0.00 HTS-P

+19.80 3

51 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+17.90 3

54 5/87 RFO ID (general) 65 % TW 0.00 HTS-P

+15.90 3

79 5/87 RFO ID (general) 96 % TW 0.00 HTS-P

+19.10 3

97 3ra7 RFO ID (general) 44 % TW 0.00 HTS-P

+16.00 4

71 5/87 RFO ID (general) 87 % TW 0.00 HTS-P

+19.90 4

73 5/87 RFO ID (general) 55 % TW 0.00 HTS-P

+15.10 4 109 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+19.30 5

50 5/87 RFO ID (general) 62 % TW 0.00 HTS-P

+18.70 5

70 5/87 RFO ID (general) 55 % TW 0.00 HTS-P

+ 4.30 5 114 5/87 RFO ID (general) 51 % TW 0.00 HTS-P

+20.00

(

44 % TW 0.00 HTS-P

+ 7.40 (general) 6 70 5/87 RFO ID 58 % TW 0.00 HTS-P

+19.00 (general) 6 95 5/87 RFO ID 58 % TW 0.00 HTS-P

+18.80 (general) 7 58 5/87 RFO ID 41 % TW 0.00 HTS-P

+20.03 (general) 8 98 5/87 RFO ID general) 44 % TW 0.00 HTS-P

+20.50 9

83.5/87 RFO ID 9 106 5/87 RFO ID (general) 48 % TW 0.00 HTS-P

+20.00 10 59 5/87 RFO ID (general) 70 % TW 0.00 HTS-P

+11.80 10 78 5/87 RFO ID (general) 55 % TW 0.00 HTS-P

+20.60 10 83 5/87 RFO ID (general) 83 % TW 0.00 HTS-P

+20.00 11 76 5/87 RFO ID (general) 63 % TW 0.00 HTS-P

+15.30 11 78 5/87 RFO ID (general) 50 % TW 0.00 HTS-P

+20.60 11 81 5/87 RFO ID (general) 91 % TW 0.00 HTS-P

+17.80 12 65 5/87 RFO ID (general) 47 % TW 0.00 HTS-P

+ 9.00 12 83 5/87 RFO ID (general) 79 % TW 0.00 HTS-P

+20.40

(

70 % TW 0.00 HTS-P

+11.80 (general) 73 % TW 0.00 HTS-P

+20.10 13 65 5/87 RFO ID general) 13 82 5/87 RFO ID 14 80 5/87 RFO ID (general) 41 % TW 0.00 HTS-P

+19.90 14 98 5/87 RFO ID (general) 79 % TW 0.00 HTS-P

+ 7.20 5/87 RFO ID (general) 47 % TW 0.00 HTS-P

+15.20 15 77 5/87 RFO ID (general) 65 % TW 0.00 HTS-P

+20.40 16 59 5/87 RFO ID (general) 58 % TW 0.00 HTS-P

+ 8.40 16 62 5/87 RFO ID (general) 83 % TW 0.00 HTS-P

+19.10 17 72 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+ 9.60 17 99 U/87 RFO ID (general) 44 % TW 0.00 HTS-P

+18.10 20 53 5/87 RFO ID (general) 41 % TW 0.00 HTS-P

+ 9.80 5/87 RFO ID (general) 50 % TW 0.00 HTS-P

+17.00 5/87 RFO ID (general) 89 % TW 0.00 HTS-P

+20.00 J

20 65 5/87 RFO ID (general) 77 % TW 0.00 HTS-P

+14 80 21 74 5/87 RFO ID (general) 77 % TW 0.00 HTS-P

+16.10 21 84 5/87 RFO ID (general) 83 % TW 0.00 HTS-P

+20.00

(

65 % TW 0.00 HTS-P

+18.90 (general) 22 70 5/87 RFO ID general) 42 % TW 0.00 HTS-P

+20.30 22 76 5/87 RFO ID 23 74 5/87 RFO ID (general) 52 % TW 0.00 HTS-P

+20.00 23 80 5/87 RFO ID (general) 65 % TW 0.00 HTS-P

+16.30 24 80 5/87 RFO ID (general) 50 % TW 0.00 HTS-P

+20.00 i

25 53 5/87 RFO ID (general) 41 % TW 0.00 HTS-P

+19.00 25 73 5/87 RFO ID (general) 79 % TW 0.00 HTS-P

+13.20 26 79 5/87 RFO ID (general) 63 % TW 0.00 HTS-P

+20.00 26 80 5/87 RFO ID (general) 63 % TW 0.00 HTS-P

+10.20

+ 8.50 27 69 5/87 RFO ID (general) 58 % TW 0.00 HTS-P

+ 7.50 5/87 RFO ID (general) 52 % TW 0.00 HTS-P 27 93 5/87 RFO ID (general) 47 % TW 0.00 HTS-P

+13.30 34 80 5/87 RFO ID (general) 74 % TW 0.00 HTS-P

+ 9.40 40 19 5/87 RFO ID (general) 41 % TW 0.00 HTS-P

+14.10

(

58 % TW 0.00 HTS-P

+17.10 (general) 41 76 5/87 RFO ID general) 44 % TW 0.00 HTS-P

+18.00 5/87 RFO ID 46 50 5/87 RFO OD WEAR 20 % TW 0.00 17

- 0.70 48 45 5/87 RFC OD WEAR 22 % TW 0.00 17 48 66 5/87 RFO OD WEAR 23 % TW 0.00 17 49 51 3/87 RFO OD WEAR 22 % TW 0.00 17

- 0.60 49 63 5/87 RFO CD WEAR 24 % TW 0.00 17

- 0.10 59 TOTAL TUBES FOUND

=

=

64 TOTAL INDICATIONS FOUND TOTAL TUBEL IN INPUT FILE =

4674

=

4560 TOTAL TUBES INSPECTED

'e+me OlME TUBmtTM) MR. 3,e)**++++ Saruem Just 4, isee ie:ii m +++++* 82C00( 4 WILCOI CO. mm pago l e1 Stocm Ganarctor: C Plent: McGUIRE UNIT 2 Outages 5/87 RFO QUERY: ATTACHMENT 3 INDICATIONS OF IMPERFECTIONS ROW COL OUTAGE INDICATION VALUE VOLTS ELEVATION INCHES


l) 42 % TW 0.00 HTS-P

+20.00 2

11 5/87 RFO ID (genera 4

88 5/87 RFO ID (general) 55 % TW 0.00 HTS-P

+12.20 4

95 5/87 RFO ID (general) 97 % TW 0.00 HTS-P

+ 7.20

(

40 % TW 0.00 HTS-P

+16.90 (general) 5 44 5/87 RFO ID 40 % TW 0.00 HTS-P

+19.80 (general) 5 74 5/87 RFO ID 40 % TW 0.00 HTS-P

+18.70 (general) 5/87 RFO ID 80 % TW 0.00 HTS-P

+19.40 (general) 8 61 5/87 Rf 7 ID 40 % TW 6.00 HTS-P

+12.60 (general) 9 17 5/87 RFO ID 40 % TW 0.00 HTS-P

+20.40 (general) 10 35 5/87 RFO ID general) 63 % TW 0.00 HTS-P

+ 3.70 10 80 5/87 RFO ID 11 68 5/87 RFO ID (general) 63 % TW 0.00 HTS-P

+11.40 11 70 5/87 RFO ID (general) 55 % TW 0.00 HTS-P

+ 4.60 5/87 RFO ID (general) 71 % TW 0.00 HTS-P

+17.70 5/87 RFO ID (general) 57 % TW 0.00 HTS-P

+18.50 13 66 5/87 RFO ID (general) 41 % TW 0.00 HTS-P

+16.60 13 76 5/87 RFO ID (general) 57 % TW 0.00 HTS-P

+13.80 14 38 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+18.80

(

40 % TW 0.00 HTS-P

+15.80 (general)

.5/87 RFO ID 92 % TW 0.00 HTS-P

+ 2.10 (general) 14 66 5/87 RFO ID 63 % TW 0.00 HTS-P

+19.30 (general) 5/87 RFO ID 44 % TW 0.00 HTS-P

+16.70 (general) 14 69 5/87 RFO ID 71 % TW 0.00 HTS-P

+19.30 (general) 5/87 RFO ID 91 % TW 0.00 HTS-P

+18.00 (general) 14 70 5/87 RFO ID 42 % TW 0.00 HTS-P

+16.20 (general) 14 71 5/87 RFO ID 62 % TW 0.00 HTS-P

+15.40 (general) 5/87 RFO ID general) 42 % TW 0.00 HTS-P

+18.80 14 76 5/87 RFO ID 14 77 5/87 RFO ID (general) 57 % TW 0.00 HTS-P

+14.90

(

46 % TW 0.00 HTS-P

+18.10 (general) 15 68 5/87 RFO ID general) 50 % TW 0.00 HTS-P

+16.00 16 109 5/87 RFO ID 5/87 RFO ID (general) 44 % TW 0.00 HTS-P

+12.00 20 48 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+17.90

(

40 % TW 0.00 HTS-P

+18.80 (general) 5/87 RFO ID 44 % TW 0.00 HTS-P

+18.00 (general) 35 44 5/87 RFO ID general) 67 % TW 0.00 HTS-P

+20.50 35 69 5/87 RFO ID 37 44 5/87 RFO ID (general) 47 % TW 0.00 HTS-P

+14.20 37 99 5/87 RFO OD (general) 20 % TW 0.00 10

+ 9.10 46 26 5/87 RFO ID (general) 41 % TW 0.00 HTS-P

+17.20 28 TOTAL TUBES FOUND

=

37 TOTAL INDICATIONS FOUND

=

TOTAL TUBES IN INPUT FILE =

4674 4558 TOTAL TUBES INSPECTED

=

I

        • DWE T12M(IM) MR.1.el*+H++ Satussar het i, asse isite Rt en** BABCDD( 4 WILCOI CO nun Pago lo8 Stocm G:ncrctor: D Plant McGUIRE UNIT 2 Outage:

5/87 RFO GUERY: ATTACHMENT 4 INDICATIONS OF IMPERFEWCTIONS ROW COL OUTAGE INDICATION VALUE VOLTS ELEVATION INCHES

-~~- --------


l) 81 % TW 0.00 HTS-P

+ 0.70 3

84 5/87 RFO ID (genera 5

36 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+20.10 5

70 5/87 RFO ID (general) 68 % TW 0.00 HTS-P

<.19.20 5 101 5/87 RFO ID (general) 73 % TW 0.00 HTS-P

+18.30 7

69 5/87 RFO ID (general) 87 % TW 0.00 HTS-P

+18.30 7

73 5/87 RFO ID (general) 68 % TW 0.00 HTS-P

+20,20 7

81 5/87 RFO ID (general) 75 % TW 0.00 HTS-P

+ 4.00 7

83 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+ 4.30 7

84 5/87 RFO ID (general) 98 % TW 0.00 HTS-P

+ 1.60 7

85 5/87 RFO ID (general) 91 % TW 0.00 HTS-P

+ 1.40 8

64 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+17.80 8 104 5/87 RFO ID (general) 85 % TW 0.00 HTS-P

+17.90 8 111 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+17.00 9

79 5/87 RFO ID (general) 79 % TW 0.00 HTS-P

+14.00 10 70 5/87 RFO ID (general) 72 % TW 0.00 HTS-P

+19.70 10 74 5/87 RFO ID (general) 49 % TW 0.00 HTS-P

+16.40 10 82 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+13.00 10 102 5/87 RFO ID (general) 50 % TW 0.00 HTS-P

+18.40 11 84 5/87 RFO ID (general) 65 % TW 0.00 HTS-P

+17.70 11 85 5/87 RbJ ID (general) 99 % TW 0.00 HTS-P

+19.80 11 95 5/87 AFO ID (general) 96 % TW 0.00 HTS-P

+13.40 11 101 5/87 RFO ID (general) 75 % TW 0.00 HTS-P

+17.30 12 86 5/87 RFO ID (general) 73 % TW 0.00 HTS-P

+18.60 12 96 5/87 RFO ID (general) 67 % TW 0.00 HTS-P

+18.70 12 101 5/87 RFC ID (general) 53 % TW 0.00 HTS-P

+18.40 12 111 5/87 RFC ID (general) 83 % TW 0.00 HTS-P

+19.10 13 55 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+19.20 13 82 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+ 4.80 13 84 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+17.20 14 81 5/87 RFO ID (general) 99 % TW 0.00 HTS-P

+ 1.40 5/87 RFO ID (general) 61 % TW 0.00 HTS-P

+ 4.20 14 82 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+16.00 14 96 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+11.40 5/87 RFO ID (general) 44 % TW 0.00 HTS-P

+19.70 16 71 5/87 RFO ID (general) 58 % TW 0.00 HTS-P

+16.20 16 92 5/87 RFO ID (general) 75 % TW 0.00 HTS-P

+ 8.30 17 99 5/87 RFO ID (general) 45 % TW 0.00 HTS-P

+17.30 19 37 5/87 RFO ID (general) 81 % TW 0.00 HTS-P

+19.00 5/87 RFO ID (general) 99 % TW 0.00 HTS-P

+18.00 5/87 RFO ID (general) 70 % TW 0.00 HTS-P

+16.20 5/87 RFO ID (general) 61 % TW 0.00 HTS-P

+14.20 19 64 5/87 RFC ID (general) 70 % TW 0.00 HTS-P

+18.90 19 83 5/87 RFO ID (general) 85 % TW 0.00 HTS-P

+ 1.50 19 102 5/87 RFO ID (general) 79 % TW 0.00 HTS-P

+16.50 5/87 RFO ID (general) 55 % TW 0.00 HTS-P

+19.40 22 101 5/87 RFO ID (general) 52 % TW 0.00 HTS-P

+14.50 22 102 5/87 RFO ID (general) 75 % TW 0.00 HTS-P

+19.30 24 64 5/87 RFO ID (general) 69 % TW 0.00 HTS-P

+19.30 3/87 RFO ID (general) 61 % TW 0.00 HTS-P

+18.30

(

83 % TW 0.00 HTS-P

+18.30 (general) 24 95 5/87 RFO ID 46 % TW 0.00 HTS-P

+19.30 (general) 24 99 5/87 RFO ID general) 98 % TW 0.00 HTS-P

+18.90 25 71 5/87 RFO ID 26 97 5/87 RFO ID (general) 40 % TW 0.00 HTS-P

+18.30 27 105 5/87 RFO ID (general) 46 % TW 0.00 HTS-P

+19.00 28 70 5/87 RFO ID (general) 58 % TW 0.00 HTS-P

+17.20 29 71 5/87 RFO ID (general) 36 % TW 0.00 HTS-P

+16.00 29 98 5/87 RFO ID (general) 49 % TW 0.00 HTS-P

+20.00 29 103 5/87 RFO ID (general) 53 % TW 0.00 HTS-P

+18.20 30 76 5/87 RFO ID (general) 58 % TW 0.00 HTS-P

+17.10 30 88 5/87 RFO ID (general) 68 % TW 0.00 HTS-P

+17.90 32 64 5/87 RFO ID (general) 55 % TW 0.00 HTS-P

+17.90 40 79 5/87 RFO ID (general) 91 % TW 0.00 HTS-P

+17.20 48 40 5/87 RFO OD WEAR 20 % TW 0.00 18 48 62 5/87 RC)

OD WEAR 21 % TW 0.00 17

=

57 TOTAL TUBES FOUND

=

64 TOTAL INDICATIONS FOUND TOTAL TUBES IN INPUT FILE =

4674 4557 TOTAL TUBES INSPECTED

=

l teste M H++H BAK!IX 4 WILCOI CD, tu+n Paga l o4

  • TMH + DWE TLSm(TM) (WR. i.e)H+n+ Sovieu Just 4, asse Stocm Gantrator: A Plent: McGUIRE UNIT 2 Outages 5/87 RFO QUERY: ATTACHMENT 5 TUBES PLUGGED ROW COL OUTAGE INDICATION VALUE VOLTS ELEVATION INCHES MECH HTS-P 2

62 5/87 RFO PLUGGED 2

63 5/87 RFO PLUGGED MECH HTS-P 2

79 5/87 RFO PLUGGED MECH HTS-P 3

60 5/87 RFO PLUGGED MECH HTS-P 4

21 5/87 RFO PLUGGED MECH HTS-P 4

68 5/87 RFO PLUGGED MECH HTG-P 5

62 5/87 RFO PLUGGED MECH HTS-P 6

56 5/87 RFO PLUGGED MECH HTS-P 8

17 5/87 RFO PLUGGED MECH HTS-P 8

38 5/87 RFO PLUGGED MECH HTS-P 9

0 5/87 RFO PLUGGED MECH HTS-P 9

54 5/87 RFO PLUGGED MECH HTS-P 10 50 5/87 RFO PLUGGED MECH HTS-P 12 44 5/87 RFO PLUGGE9 MECH HTS-P 12 63 5/87 RFO PLUGGED MECH HTS-P 13 36 5/87 RFO PLUGGED MECH HTS-P 15 30 5/87 RFO PLUGGED MECH HTS-P 15 68 5/87 RFO PLUGGED MECH HTS-P 16 31 5/87 RFO PLUGGED MECH HTS-P 17 34 5/87 RFO PLUGGED MECH HTS-P 18 24 5/87 RFO PLUGGED MECH HTS-P 18 27 5/87 RFO PLUGGED MECH HTS-P 18 29 5/87 RFO PLUGGED MECH HTS-P 19 33 5/87 RFO PLUGGED MECH HTS-P 19 70 5/87 RFO PLUGGED MECH HTS-P 27 48 5/87 RFO PLUGGED MECH HTS-P 32 40 5/87 RFO PLUGGED MECH HTS-P 34 21 5/87 RFO PLUGGED MECH HTS-P 34 74 5/87 RFO PLUGGED MECH HTS-P 35 45 5/87 RFO PLUGGED MECH HTS-P 37 43 5/87 RFO PLUGGED MECH HTS-P 38 61 5/87 RFO PLUGGED MECH HTS-P 43 45 5/87 RFO PLUGGED MECH HTS-P 43 59 5/87 RFO PLUGGED MECH HTS-P 44 37 5/87 RFO PLUGGED MECH HTS-P 35 TOTAL TUBES FOUND

=

=

35 TOTAL INDICATIONS FOUND TOTAL TUBES IN INPUT FILE =

4674 4559 TOTAL TUBES INSPECTED

=

4

" ' ' ~ ^ ' '

en----.-

"* ++++ DWE TL11mim MR.1.e)*+++++ Satussay Just 9 tsee te sti Rt ++++++ BABCOD( 4 WILCOI CD, ++++++ pa go lof Stocm Gsnarctor: B Plcnt: McGUIRE UNIT 2 Outage:

5/87 RFO QUERY: ATTACHMENT 6 TUBES PLUGGED ROW COL OUTAGE INDICATION VALUE VOLTS ELEVATION INCHES MECH HTS-P 2

58 5/87 RFO PLUGGED 2

81 5/87 RFO PLUGGED MECH HTS-P 2

82 5/87 RFO PLUGGED MECH HTS-P 3

51 5/87 RFO PLUGGED MECH HTS-P 3

54 5/87 RFO PLUGGED MECH HTS-P 3

79 5/87 RFO PLUGGED MECH HTS-P 3

97 5/87 RFO PLUGGED MECH HTS-P 4

71 5/87 RFO PLUGGED MECH HTS-P 4 109 5/87 RFO PLUGGED MECH HTS-P 5

50 5/87 RFO PLUGGED MECH HTS-P 5 114 5/87 RFO PLUGGED MECH HTS-P 6

95 5/87 RFO PLUGGED MECH HTS-P 6 102 5/87 RFO PLUGGED MECH HTS-P 7

58 5/87 RFO PLUGGED MECH HTS-P 8

98 5/87 RFO PLUGGED MECH HTS-P 9

83 5/87 RFO PLUGGED MECH HTS-P 9 106 5/87 RFO PLUGGED MECH HTS-P 10 78 5/87 RFO PLUGGED MECH HTS-P 10 83 5/87 RFO PLUGGED MECH HTS-P 11 65 5/87 RFO PLUGGED MECH HTS-P 11 78 5/87 RFO PLUGGED MECH HTS-P 12 83 5/87 RFO PLUGGED MECH HTS-P 13 55 5/87 RFO PLUGGED MECH HTS-P 13 82 5/87 RFO PLUGGED MECH HTS-P 14 80 5/87 RFO PLUGGED MECH HTS-P 15 77 5/87 RFO PLUGGED MECH HTS-P 16 62 5/87 RFO PLUGGED MECH HTS-P 17 72 5/87 RFO PLUGGED MECH HTS-P 20 53 5/87 RFO PLUGGED MECH HTS-P 21 84 5/87 RFO PLUGGED MECH HTS-P 22 70 5/87 RFO PLUGGED MECH HTS-P 22 76 5/87 RFO PLUGGED MECH HTS-P 23 61 5/87 RFO PLUGGED MECH HTS-P 23 74 5/87 RFO PLUGGED MECH HTS-P 24 80 5/87 RFO PLUGGED MECH HTS-P 25 53 5/87 RFO PLUGGED MECH HTS-P 25 91 5/87 RFO PLUGGED MECH HTS-P 26 79 5/87 RFO PLUGGED MECH HTS-P 27 16 5/87 RFO PLUGGED MECH HTS-P 40 19 5/87 RFO PLUGGED MECH HTS-P 41 76 5/87 RFO PLUGGED MECH HTS-P 47 80 3/87 RFO PLUGGED MECH HTS-P 42 TOTAL TUBES FOUND

=

42 TOTAL INDICATIONS FOUND

=

TOTAL TUBES IN INPUT FILE =

4674 4560 TOTAL TUBES INSPECTED

=

se at s MI ++++++ BABCDD( 4 WILCor CD. +++** Pcgm l of

- ++++++ dug TUBM(im (VER.

3.el++++++ Satusear Jue 4, ases Plent: McGUIF.E UNIT 2 Storm Gancretor: C Outago:

5/87 PFO GUERY: ATTACHt1ENT 7 TUBES PLUGGED ROW COL OUTAGE INDICATION VALUE VOLTS ELEVATION INCHES MECH HTS-P 2

11 5/87 RFO PLUGGED 4

95 5/87 RFO PLUGGED MECH HTS-P 5

74 5/87 RFO PLUGGED MECH HTS-P 5

92 5/87 RFO PLUGGED MECH HTS-P 8

18 5/87 RFO PLUGGED MECH HTS-P 8

61 5/87 RFO PLUGGED MECH HTS-P 10 35 5/87 RFO PLUGGED MECH HTS-P 10 80 5/87 RFO PLUGGED MECH HTS-P 11 70 5/87 RFO PLUGGED MECH HTS-P 12 72 5/87 RFO PLUGGED MECH HTG P 12 80 5/87 RFO PLUGGED MECH HTS-P 14 18 5/87 RFO PLUGGED MECH HTS-P 14 38 5/87 RFO PLUGGED MECH HTS-P 14 66 5/87 RFO PLUGGED MECH HTS-P 14 69 5/87 RFO PLUGGED MECH HTS-P 14 70 5/87 RFO PLUGGED MECH HTS-P 15 68 5/87 RFO PLUGGED MECH HTS-P 15 78 5/87 RFO PLUGGED MECH HTS-P 16 109'5/87 RFO PLUGGED MECH HTS-P 19 29 5/87 RFO PLUGGED MECH HTS-P 19 98 5/87 RFO PLUGGED MECH HTS-P 20 48 5/87 RFO PLUGGED MECH HTS-P 20 64 5/87 RFO PLUGGED MECH HTS-P 22 61 5/87 RFO PLUGGED MECH HTS-P 22 98 5/87 RFO PLUGGED MECH HTS-P 22 103 5/87 RFO PLUGGED MECH HTS-P 30 93 5/87 RFO PLUGGED MECH HTS-P 35 44 5/87 RFO PLUGGED MECH HTS-P 35 69 5/87 RFO PLUGGED MECH HTS-P 46 26 5/87 RFO PLUGGED MECH HTS-P

=

30 TOTAL TUBES FOUND

=

30 TOTAL INDICATIONS FOUND TOTAL TUBES IN INPUT FILE =

4674

=

4558 TOTAL TUBES INSPECTED 1

i

+++++e DL*E Rem (TM) MR. i.e)++++++ Setocear het i, isse teste C ++++++ gac00( 3 utLcc1 a), **** pegolg('

4 Plant McGUIRE UNIT 2 Stocm G:nsrctor: D Outcgo 5/87 RFO QUERY: ATTACHMENT 8 TUBES PLUGGED ROW COL OUTAGE INDICATION VALUE VOLTS ELEVATION INCHES 5

36 5/97 RFO PLUGGED MECH HTS-P 5

70 $/87 RFO PLUGGED MECH HTS-P 7

17 5/87 RFO PLUGGED MECH HTS-P 7

69 5/87 RFO PLUGGED MECH HTS-P 7

73 5/87 RFO PLUGGED MECH HTS-P 8 104 5/87 RFO PLUGGED MECH HTS-P 9

82 5/87 RFO PLUGGED MECH HTS-P 10 70 5/87 RFO PLUGGED MECH HTS-P 10 102 5/87 RFO PLUGGED MECH HTS-P 11 84 5/87 RFO PLUGGED MECH HTS-P 11 85 5/87 RFO PLUGGED MECH HTS-P 12 86 5/87 RFO PLUGGED MECH HTS-P 12 96.5/87 RFO PLUGGED MECH llTS-P 12 101 5/87 RFO PLUGGED MECH HTS-P 12 111 5/87 RFO PLUGGED MECH HTS-P 13 55 5/87 RFO PLUGGED MECH HTS-P 14 96 5/87 RFO PLUGGED MECH HTS-P 18 84 5/87 RFO PLUGGED MECH HTS-P 19 37 5/87 RFO PLUGGED MECH HTS-P 19 64 5/87 RFO PLUGGED MECH HTS-P 19 69 5/87 RFO PLUGGED MECH HTS-P 19 102 5/87 RFO PLUGGED MECH HTS-P 22 101 5/87 RFO PLUGGED MECH HTS-P 22 102 5/87 PFO PLUGGED MECH HTS-P 24 64 5/87 RFO PLUGGED MECH HTS-P 24 95 3/87 RFO PLUGGED MECH HTS-P 24 99 5/87 RFO PLUGGED MECH HTS-P 25 71 5/87 RFO PLUGGED MECH HTS-P 26 97 5/87 RFO PLUGGED MECH HTS-P 27 105 5/87 RFO PLUGGED MECH HTS-P 29 98 5/87 RFO PLUGGED MECH HTS-P 32 64 5/87 RFO PLUGGED MECH HTS-P 47 58 5/87 RFO PLUGGED MECH HTS-P 48 58 5/87 RFO PLUGGED MECH HTS-P

=

34 TOTAL TUBES FOUND

=

34 TOTAL INDICATIONS FOUND TOTAL TUBES IN INPUT FILE =

4674

=

4557 TOTAL TUBES INSPECTED i