Forwards Assessment of Structural Adequacy of Concrete Foundation Cells for Emergency Raw Cooling Water Pumping Station & Access Roadway, in Response to Unresolved Items in Insp Repts 50-327/88-12 & 50-328/88-12
ML20155J565
Person / Time
Site: Sequoyah  
Issue date: 10/20/1988
From: Gridley R
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20155J570 List:
References
TAC-R00488, TAC-R00489, TAC-R488, TAC-R489, NUDOCS 8810260382
Download: ML20155J565 (3)


Text

_ _ _ _ _ - _ _ _ _

TENNECCEE VALLEY AUTHORITY CHATTANOOOA TENNESSEE 37401 SN 1578 Lookout Place 00T 201988 t

U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk L

Washington, D.C.

20555 Gentlemen:

In the Matter of

)

Docket Nos. 50-327 Tennessee Valley Authority

)

50-328 SEQUO1 AH NUCLEAR PLANT (SQN) - ESSENTIAL RAW COOLING WATER (ERCW)

PUMPHOUSE FOUNDATION AND ERCH PUMPING STATION ACCESS CELLS This is in response to Inspection Report 50-327, 328/88-12, unresolved items 88-12-05 and 88-12-09. An evaluation has been performed by Bechtel North American Power Company on the ERCW pumphouse foundation and pumping station access roadway foundation.

This evaluation report is enclosed.

1 It was concluded that the ERCH pumping station and access roadway cells are structurally adequate and will function as intended under the design loads. However, a limited exploration program for the pumphouse foundation is recommended to augment the available data used in i

evaluating the foundation.

TVA requests a meeting with NRC on either j

November 7 or November 14, 1988, to answer questions and get NRC approval j

for the proposed exploration program.

l Please direct cuestions concerning this issue to K. S. Whitaker at (615) 870-7748.

]

l Very truly yours, f

f TENNESSEE VALLEY AUTHORITY I

Q/b 7,,

i R. Grid ey, Managet Nuclear Licensing anc l

l Regulatory Affairs Enclosure cc:

See page 2 l

gN,\\

8910260392 SS1020 j

PDR ADOCK 05000327 i

o PEC An Equal Opportunity Employer 6

l

l 1

~

! l U.S. Nuclear Regulatory Commission OST 20 B88 1

l cc (Enclosure)-

Ms. S. C. Black, Assistant Director for Projects i

TVA Projects Olvision 1

U.S. Nuclear Regulatory Commission l

4 One White Flint, North 11555 Rockville Pike Rockville, Marylanti 20852 Mr. F. P. McCoy, Assistant Director j

for Itilpection Programs TVA Projects Olvision U.S. Nuclear Regulatory Commission l

Region II i

101 Marietta Street, NW, Suite 2900 j

Atlanta, Georgia 30323

[

1 j

Sequoyah Resident Inspector l

Sequoyah Nuclear Plant i

2600 Igou Ferry Road 4

Soddy Datsy Tennessee 37379

.I l

I i

i t

[

]

i l

l I

?

l 1

l 4

)

I i

I

l ENCLOSURE "Assessment of Structural Adequacy of the Concrete Foundation Cells for the Emergency Raw Cooling Water Pumping Station and Access Roadway" Sequoyah Nuclear Plant J