9 GPU Nuclear Corporation g
gf Post Office Box 480 Route 441 South Middletown, Pennsylvania 17057 0191 717 944 7621 TELEX 84 2386 Writer's Direct Dial Number:
(717) 948-8461 4410-86-L-0085 Document ID 1654X May 20, 1986 TMI-2 Cleanup Project 91 rectorate Attn: Dr. H. D. Travers Director US Nuclear Regulatory Commission c/o Three Mlle Island Nuclear Station Middletown, PA 17057
Dear Dr. Travers:
Three Mile Island Nuclear Station, Unit 2 (TMI-2)
Operating License No. DPR-73 Docket No. 50-320 Defueling Safety Evaluation Report - Revision 10 Attached are two pages (pages 67 - 68) of the Defueling Safety Evaluation Report (SER), Revision 10, which were inadvertently omitted from the copy distributed by GPU Nuclear letter 4410-86-L-0049, dated May 15, 1986.
Please incorporate these pages into your copy of the subject document.
Sincerely, l
/w F'. R. Standerfe Vice President / Director, THI-2 FRS/RBS/sle Attachment 0$
(~ M 55303T4'860526
._,,)
0 AD 05
)
\\\\
GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corpcration
SA-4350-3261-85-1 15737-2-G07-108 y
Table 5.3-1 Jobhours and Person-rem Expended Through March 31, 1986 Activity Jobhours Person-rem Preparations, installations 3,930 100 Operations 9,300 86 3
Maintenance 1,825 27 Decontamination and Removal
- 0 0
Totals 15,055 213
- No activity associated with final decontamination and removal of defueling equipment has been performed as of March 31, 1986, thus no jobhours and person-rem are given. Note, decontamination maintenance in the reactor building is not considered part of this activity.
s Rev. 10 0404Y
SA-4350-3261-85-1 15737-2-G07-108 p
Table 5.3-2 Estimated Jobhours and Person-rem for Remainder of Defueling Defueling Support Jobhours Person-rem 305' 2,650 200 347' 8,050 403 CHB (containment) 440 9
Defueling Platform 15,600 156 Defueling Operations CHB (containment) 1,000 20 Defueling Platform 22,000 220 CHB (FHB) 2,000 4
Maintenance CHB (containment) 300 6
Defueling Platform 1,500 15 CHB (FHB) 100 1
Decontamination and Removal 305' 252 19 347' 2,264 114
-CHB (containment) 600 12 Defueling Platform 1,950 20 Totals 58,706 1,199 Rev. 10 0404Y l
_ _ _ _ _ _ _