Text
.
- /N!!
00CKETED USNRC November 6,1998 UNITED STATES OF AMEREANOV -9 P2 :52 NUCLEAR REGULATORY COMMISSION O&;
BEFORE THE PRESIDING OFFICER.
_g
)
In the Matter of
)
)
MICHEL A. PHILIPPON
)
Docket No. 55-32443-SP
)
(Denial of Senior Reactor Operator
)
License Application)
)
)
NRC STAFF'S ANSWER TO REQUEST FOR HEARING FILED BY MICHEL A.PHILIPPON CONCERNING DENIAL OF SENIOR REACTOR OPERATOR LICENSE APPLICATION The NRC Staff, pursuant to 10 C.F.R. 6 2.1205(g), hereby submits its answer to the request for hearing filed by Michel A. Philippon, dated October 16,1998, in regard to the denial of Mr. Philippon's application for a senior reactor operator license. For the reasons set forth below, the Staff does not object to Mr. Philippon's hearing request.
BACKGROUND In April 1998, Mr. Philippon took an examination for a senior reactor operator license.
The Staffissued a proposed denial of the license, for failure to pass the operating test portion of i
the examination, on May 20,1998. On July 2,1998, Mr. Philippon requested an NRC review of the grading of his examination. Following an informal review by the Staff and an evaluation by an Appeal Panel, Mr. Philippon was informed by the Staff by letter dated October 4,1998, that he did not pass the operating test. The Staff's letter also provided Mr. Philippon with an j
opportunity to request a hearing within twenty days. By letter dated October 16, 1998, i
9811120037 981106 PDR MISC A
9811120037 PDR
])
l
~
?
g-i Mr. Philippon requested a hearing. On October 28,1998, the Presiding Officerin this proceeding was designated.
DISCUSSION Mr. Philippon was provided with an opportunity to request a hearing concerning the denial of his senior reactor operator license until October 24,1998. He filed his request for a hearing within the time allowed. Accordingly, the Staff does not object to Mr. Philippon's hearing request.
CONCLUSION The Staff does not object to the granting of the hearing request filed by Mr. Philippon.
Respectfully submitted,
/j f
Steven R. Hom Counsel for NRC Staff Dated at Rockville, Maryland this 6th day of November 1998
a DOCKETED o'
UNITED STATES OF AMERICA USNRC NUCLEAR REGULATORY COMMISSION In the Matter of
)
)
MICHEL A. PHILIPPON
)
Docket No.55-32443@{.F 9
[
}
ADJlg,
,WF (Denial of Senior Reactor Operator
)
. License Application)
)
NOTICE OF APPEARANCE Notice is hereby given that the undersigned attorney enters an appearance in the above-captioned matter in accordance with 10 C.F.R. f 2.713.
Name:
Steven R. Hom Address:
Office of the General Counsel U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Telephone Number:
(301) 415-1537 Fax Number:
(301) 415-3725 E-Mail Address:
srh@nrc. gov Admissions:
United States Court of Appeals for the Ninth Circuit State of New York State of California Name of Party:
NRC Staff Respectfully submitted, even R. Hom Counsel for NRC Staff Dated at Rockville, Maryland this 6th day of November 1998 l
t UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION 1
00CKETED USHRC BEFORE THE PRESIDING OFFICER In the Matter of
)
'96 NOV -9 P2 52
)
MICHEL A. PHILIPPON
)
Docket No. 55-3@3.-SPc r SE
)
RULWr (Denial of Senior Reactor Operator
)
ADJUDO RFF s
License Application)
)
CERTIFICATE OF SERVICE I hereby certify that copies of "NRC STAFF'S ANSWER TO REQUEST FOR HEARING FILED BY MICHEL A. PHILIPPON CONCERNING DENIAL OF SENIOR REACTOR OPERATOR LICENSE APPLICATION" and " NOTICE OF APPEARANCE" for Steven R. Hom,in the above-captioned proceeding have been served on the following by U.S.
Mail, first class, or, as indicated by a single asterisk through deposit in the Nuclear Regulatory Commission's internal mail system, this 6th day of November,1998:
Administrative Judge Adjudicatory File * (2)
Thomas S. Moore
- Atomic Safety and Licensing Board Presiding Officer.
Mall Stop: T-3 F23 Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Mail Stop T-3 F23 Washington,DC 20555 U.S. Nuclear Regulatory Commission Washington, DC 20555 Atomic Safety and Licensing Board FAX: 301-415-5595 Panel
- j Mail Stop: T-3 F23 Administrative Judge U.S. Nuclear Regulatory Commission l
Dr. Charles N. Kelber*
Washington,DC 20555 Special Assistant Atomic Safety and Licensing Board Secretary * (2)
Mail Stop T-3 F23 Attn: Rulemakings and U.S. Nuclear Regulatory Commission Adjudications Staff Washington, DC 20555 Mail Stop: OWFN-16 Cl U.S. Nuclear Regulatory Commission Michel A.Philippon Washington,DC 20555 13871 Capernall Road Carleton, MI 48117 Office of Commission Appellate Adjudication
- Mail Stop: OWFN-16 C-1 U.S. Nuclear Regulatory Commission Washington,DC 20555 SEven R. Hom Counsel for NRC Staff