Amends 39 & 21 to Licenses NPF-11 & NPF-18,respectively, Changing Tech Spec Alarm Calibr Setpoint to Greater than or Equal to 940 Psig
ML20155H061
Person / Time
Site: LaSalle  
(NPF-11-A-039, NPF-11-A-39, NPF-18-A-021, NPF-18-A-21)
Issue date: 05/06/1986
From: Adensam E
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20155H065 List:
References
NUDOCS 8605120175
Download: ML20155H061 (8)


Text

.

/pulcoq'o UNITED STATES NUCLEAR REGULATORY COMMISSION

{

1f[nj.i WASHINGTON, D. C. 20555 ye 8

%,* v 4,e COMMONWEALTH EDISON COMPANY DOCKET NO. 50-373 LA SALLE COUNTY STATION, UNIT 1 7

AMENDMENT TO FACILITY OPERATING LICENSE Amendn'ent No. 39 License No. NPF-11 1.

The Nuclear Regulatory Comission (the Comission or the NRC) having found that:

A.

The applications for amendment filed by the Commonwealth Edison Company (the licensee), dated August 27, 1985, and April 4,1986, comply with the standards and requirements of the Atomic Enercy Act of 1954, as amended (the Act), and the Comission's regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the regulations of the Comission; C.

There is reasonable assurance: (i) that the activities authorized by 3

this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted ia compliance with the Comission's regulations set forth in 10 CFR Chapter I; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable -requirements have been satisfied.

?.. Accordingly, the license is amended by changes to the Technical Specifica-tions as indicated in the enclosure to this license amendment and paraoraph 2.C.(2) of the Facility Operating License No. NPF-11 is hereby amended to read as follows:

(2) Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No. 39, and the Environmental Protection Plan contained in Appendix B, are hereby incorporated in the license. The licensen shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

8605120175 860506

~

PDR ADOCK 05000373 P

PDR

3.

This amendment is effective as of date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Z & +n'r lfw P

Elinor G. Adensam, Director BWR Project Directorate No. 3 Division of BWR Licensing

Enclosure:

Changes to the Technical Specifications Date of Issuance: May 6,1986

ENCLOSURE TO LICENSE AMENDMENT NO. 39 FACILITY OPERATING LICENSE NO. NPF-11 DOCKET NO. 50-373 Replace the following pace of the Appendix "A" Technical Specifications with -

the enclosed page. The revised page is identified by Amendnent number and contains a vertical line indicating the area of change.

REMOVE INSERT 3/4 1-10 3/4 1-10 t

J I

i r

REACTIVITY CONTROL SYSTEM SURVEILLANCE REQUIREMENTS 4.1.3.5 Each control rod scram accumulator shall be determined OPERABLE:

a.

At least once per 7 days by verifying that the indicated pressure is greater than or equal to 940 psig unless the control rod is inserted and disarmed or scrammed.

I b.

At least once per 18 months by:

1.

Performance of a:

a)

CHANNEL FUNCTIONAL TEST of the leak detectors, and i

b)

CHANNEL CALIBRATION of the pressure detectors, with the alarm setpoint > 940 psig on decreasing pressure.

y I

l I

i 1

i l

LA SALLE - UNIT 1 3/4 1-10 Amendment No. 39 1

~(

UNITED STATES E"

NUCLEAR REGULATORY COMMISSION c

[,

.E WASHINGTON, D. C. 20555

\\,

/

COMMONWEALTH EDIS0N COMPANY DOCKET NO. 50-374 LA SALLE COUNTY STATION, UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 21 License No. NPF-18 1.

The Nuclear Regulatory Commission (the Commission or the NRC) having found that:

A.

The applications for amendment filed by the Commonwealth Edison Company (the licensee), dated August 27, 1985, and April 4, 1986, comply with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Connission's regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the regulations of the Comission; C.

There is reasonable assurance: (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifica-tions as indicated in the enclosure to this license amendment and paragraph 2.C.(2) of the Facility Operating License No. NPF-18 is hereby amended to read as follows:

(2) Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No. 21, and the Environmental Protection Plan contained in Appendix B, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications and i

the Environmental Protection Plan.

S

(

2_

3.

This amendment is effective upon date of issuance.

FOR THE NUCLEAR 9EGULATORY COPMISSION f

Ohii tunu s.

t Elinor G. Adensam, Director BWR Project Directorate No. 3 Division of BWR Licensing

Enclosure:

Changes to the Technical Specifications Date of Issuance: May 6,1986 h

j i.

f I

f.

i F

I I

w-

.,~. -, _. _, -

ENCL 01URE TO LICENSE AMENDMENT NO. 21 FACILITY OPERATING LICENSE NO. NPF-18 DOCKET NO. 50-374 Replace the following page of the Appendix "A" Technical Specifications with the enclosed page. The revised page is identified by Amendment number and contains a vertical line indicating the area of change.

REMOVE INSERT 3

3/4 1-10 3/4 1-10 i

F i

I 1

f' i

i

?

r

-e

^

REACTIVITY CONTROL SYSTEMS SURVEILLANCE REQUIREMENTS 4.1.3.5 Each control rod scram accumulator shall be determined OPERABLE:

a.

At least once per 7 days by verifying that the indicated pressure is greater than or equal to 940 psig unless the control rod is inserted' and disarmed or scrammed.

b.

At least once per 18 months by:

1.

Performance of a:

a)

CHANNEL FUNCTIONAL. TEST of the leak detectors, and b)

CHANNEL CALIBRATION of the pressure detectors, with the alarm setpoint > 940 psig on decreasing pressure.

l

~

i l

i 1

I i

LA SALLE - UNIT 2 3/4 1-10 Amendment No. 21 i