J -.

A ED ED M ED D November 3,1998

' Docket No. 70-36 License No. SNM-33 Director, Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001

Subject:

SUPPLEMENT TO HIENNIAL UPDATE OF SNM-33 DEMONSTRATION SECTIONS

Reference:

CE's submission of SNM-33, Part II, dated October 28,1998

Dear Sir:

The referenced biennial update to the SNM-33 demonstration sections inadvertently omitted the figures at the end of Chapter 14. In addition, certain text of three drawings in other chapters was difficult to read. This supplement provides the missing drawings and replaces the other drawings with clarified ones. There were no changes made to the text of the October 28 submission.

Enclosed is a description of these changes and a listing of affected pages. Six copies of this document are provided for your use.

Please contact me at (314) 937-4691, extension 399, if there are any questions.

Sincerely, COMBUSTION ENGINiiERING,INC.

Robert ' Sharkey Director, Regulatory Affairs RA9M D

,3 cc: Dr. Sean Soong hI

/

i d

i y.

  • 4 s,

\\.

O Y %4 t

ABB CENO Fuel Operations Combust on Engineenng Inc 3300 State Roact P Telephone (314) 937-4691 Post othce Box 107 St Louis (314) 296 SMO 9811090170 981103 5

HemaMe Wm 63047 Fa4314) 937-7955 PDR ADOCK 07000036, C

PDR L m

L

O 9

Enclosure to RA98/823 November 3,1998 COMilUSTION ENGINEERING, INC.

SUPPLEMENT TO IIIENNIAL UPDATE OF LICENSE NO. SNM-33 PART II DESCRIPTION OF CIIANGES On October 28,1998 Combustion Engineering, Inc. submitted revised safety demonstration sections (Part II) to our license application to comply with condition 1.6(d). The sections were updated to reficct current operations and to include operational data and information on current environmental releases. Editorial changes and corrections were made and the sections were repaginated. Since the formatting was changed and the revised Part 11 was submitted in its entirety, this edition was designated

" revision 1" with a common date for all pages.

The October 28 submission inadvertently omitted the figures at the end of Chapter 14. In addition, text of three drawings in other chapters was difficult to read. This supplement provides the missing drawings and replaces the other drawings with clarified ones. There were no changes made to the text of the October 28 submission, so the " revision 1" designation and the October 28 date is retained on the supplement pages.

A brief description of significant changes follows:

Chapter 9-GENERAL INFORMATION-Figure 9-4 was revised to remove shading which obscured building numbers and area descriptions.

Chapter 13-ENVIRONMENTAL SAFETY - RADIOLOGICAL-Figure 13-2 was revised to remove shading which obscured sample well locations and the drawing scale chart.

Chapter 14-CRITICALITY SAFETY-Figures 14-1 through 14-27 were omitted and are now provided.

Chapter 15-PROCESS DESCRIPTION AND SAFETY ANALYSIS-Figure 15.2-1 was revised to delete unreadable wording carried over from the engineering drawing and to clearly identify the IIF absorber system.

Enclosure to RA98/823 l

November 3,1998 COMBUSTION ENGINEERING,INC.

SUPPLEMENT TO BIENNIAL UPDATE OF LICENSE NO. SNM-33 PART II AFFECTED PAGES l

Affected naces are:

Chapter 9 - Replace page 9-9 Chapter 13 - Replace page 13-4 l

Chapter 14 - Add pages 14-53 through 14-79 Chapter 15 - Replace page 15-20 l

f I'

l i

P 7

v-a

g i

Enclosure to RA98/823 November 3,1998 l

l l

l i

l COMilUSTION ENGINEERING, INC.

LICENSE NO. SNM-33, PART II, SAFETY DEMONSTRATION SUPPLEMENTAL REVISED PAGES I

l i

l November 3,1998 r

i

o 9.4.6 Seismological The east central Missouri general area is relatively active seismically. The southeastern area 1

of Missou~riis quite active seismically and also contains a portion of the New Madrid Fault that caused the " great earthquake" of 1811 and 1812. There were three quakes of Epicentral j

Intensity XII Modified Mercalli scale (M.M.) which took place on December 6,1811 and January 23 and February 7,1812, near New Madrid. During recent years, there have been two quakes recorded in the New Madrid area. In 1962 a quake measuring V (M.M.) was recorded and one j

with a magnitude of 4.5 was recorded in 1963. A quake reported as "the strongest in years" j

occurred near Caruthersville, Missouri,150 miles southeast of Hematite, on December 3, I

1980.

f 9.5 Locations of Buildings on Site Figure 9-4 shows the location of and identifies the buildings and facilities on the Hematite site.

Figure 9-4 l

Building Identification and Location i

)

)

A/

State Road P Tile Barn Wood Barn Bid. 115 Bldg. 1 W ---- ----- --. -


.i J

Parking Lot - Y

- r-.'g


M%q,

- d9A

,,1j j

i Rod Load i

and Assembly Bldg g > *e f

23 Building Ertnum (Bldg. 230)

Pellet Pellet y

RWe l ***

L**

f UO2 o

e Area Bido 254 Badg 255 j

j 3,,,,g, idg.24o

(.....

,s

, "ly Shop Poem p y

. F-bs

--a coot 0'Ti p i g.......',

T g

==+,.

i

~

~~~

South Vault

""**-...,,"......l Town of Hematite l

Bidg. 252 l

]

3/4 mile

t.....g,,......g.g.......... g..g.[,,

g 20 g Buildings y i n,,,,,,

y 300,,,,,,

0 o

so 100 E Pavement w

.... pence License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 9-9

s Figure 13-2 Locations of Water Monitoring Sites 4

Hematite N

i Plant Site i

Current Site Boundary 228 Acres i

\\

Fenced 14 Union Area State

.d P '

Small Creek

-= Pacific 10'

--~~ =" # =""""'-=

Railroad

~'

15 # e O

13 Joachim 7 # o'"

12 Creek 4

g je 8 11

'228 Acres]

I

,S HEMATITE Sample Table 3

No.

No.

Description 1e,

1 13-6 Hematite Well 2

13-4 Joachim Creek-Upstream 3

13-6 Joachim Creek-Confluence 2

/

4 13-5 Joachim Creek - Downstream 5

13-14 Sewage Outfall 6

13-3 Site Dam Overflow 7

13-7 Retention Pond Well-North 8

13-8 Retention Pond Well-Southeast 9

13-9 Retention Pond Well-Southwes' 10 13-11 South Vault Well 11 13-13 Burial Ground Well #4 12 13-12 Burial Ground Well #1 e Location of Monitoring Sites 13 13-13 Burial Ground Well #3 14 13-12 Burial Ground Well #2 15 13-10 Site Well License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 13-4

l_:

. KgUO2 o Vo I ume( L) o Cy l. D to. ( in )

Sieb T(in) 4 o gUO2/cm2


OP-1014 G

\\

~

UKAEA

\\

\\

o s

)

N

  • 'k

\\

c " :-

N 03 s.s O

~

s

{

s s,

~~_

s, s

e_

~

..ii

...iiiiii....si.

...... iii...

1 2

3 4

5 w/o U-235 Figure 14-1 Reflected and Ootimally Moderated. Critical Parameters versus Enrichment License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-53

OC 88 50_________________._-_________________

i'i 5l UnreRected U493.5) Sphers

~e 40 m

a <o

~

Al i'

wh x

s NAwe

~

?e j

T ?A "o

x 20 a

\\

\\

i k k N

x

'g

\\

U(N) CS-312

\\

i

\\

G N =raphite E.

m s

a

\\

10 a

w 8

1 5

10 20 30' 40 50 60 ReflectorThickness (cm)

Figure 14-2 TO c3 n>

Critical Masses of U(93.5) Metal Spheres in Various Reflectors

% HI Uranium Density - 18.8 g/cc

]4 (from LA-10860-MS) g

i 18-assooDP-1014

  • * * *

+ + + + + CE-A l t.. B t o. Curv. f' a u u CE-Re f. O tes Curvy

/

t i

16.

j m

/

E o

/

/

v F-

/

14-

/

_O d '

/

0

/

CO j

/

12.

p

/

10'.,,.

0 2

4 6

8 10 Water to Oxtde Re t to Figure 14-3 Reflected Critical Sitb Thickness versus Water-to-0xide Ratio for 0.40" OD U(510, 'ellets Uniforsiv Distributed in Water i

i a

License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-55 l

m N -

E R-o o

a a.r.s.s DP-1014 g

..... CE-A l t. B t e. Curve g

  • u u CE-Re f. B la s Curve O

J o) :

v g-C m

e 5

O e

O 0$

L 3

s

__ M W,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,

0 2

4 6

8 10 12 14 Weter to Oxtde Re t to Figure 14-4 Reflected critical surrace censity versus water-to-Oxide Ratio for 0.40" 00 U(510, Pellets Uniforely Distributed in Water License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-56

4 N_

ocoo=DP-1014

]-

.....UKAEA

..... CE-A l t.. B l e s Curve

[

U

. u u CE-Re f. Bles Curve /

o

/

u>

/

3

)

"k

/

'O f

C 4,

Q I

1 L

/

O l

0

/

c C-

/

s

/

l

/

/

x.

U s,

3

'I E

3 3

I l

8 8

I B

l 3

iy il e s e a g 6.00 2.00 4.00 6.00 8.00 10.00 I

Weter to Oxtde Re t to l

l Figure 14 5 Reflected Critical Radius versus Water-to-Oxide Ratio for 0.40' OD UI510, Pellets Unifomly Dirtributed In Water i

l l

t License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-57

g.

oooooDP-1014

.....UKAEA

^J

,,,,.CE-Alt..Bles Curvo m

  • u u CE-Re f. Stos Curve v

o E

~

3 u

/

O

/

/

/

/

c O

a I

L k-I e

1 e

/

.c a.

/

(f)

/

s g

O 2

4 6

8 10 Weter to Oxtde Re t to Figure 14-6 Reflected Critical Scherical Volume versus Water to-Oxide Ratio for 0.40' 00 U(5]p, Pellets Uniforalv Distributed In WatE l

License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-58

=__.. _.

l t-

.....DP-1014 o

gI

' ' ' '

^

    • "+ CE-Al t.. B t e s Curve N

+ u u CE-Re f. 8tes Curve i

O

'D08::

v ~:

v w 8::

e o

1 r::

/

/

~

~_s' w

$.....d.........,,,,,,,,,,

O 4

6 8

10 Weter to Oxide Re t to Figure 14-7 Reflected Critical Scher4 cal Mass versus Water to-Oxide Ratio for 9 40" OD Uf 5)Q, Pellets Uniforely Distributed In Water l

i l

l License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-59

n-

"1 I

b G

  • * = *
  • 0. 05 tn. Pe l l e t O gl:<

.... 0.1 e (n. Pe i i e t

]-

= = = = = 0. 20 in. P. I I e t

  • * * *
  • 0. 40 in. Pe l l e t
0) *-

u+

u-o n.

O a

n-l L

U8-j x>

l 4Aidei e

s 4

ei144' 1

10 l

Weter to Oxtde Re t to l

Figure 14-8 Reflected Critical Mass versus Water-to-Oxide Ratio for El1Q, Pellets of Different D'ameters I

l l

V License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-60

.~

l l

l lE:

  • * * = = DP-1014
  • * * *
  • CE-Re f. B t e. Curve 8'

(N O

a:

m_

l T.

G -

u 4dI e:

T.

?

l

...... i,i i iiiii..........,,i 0

0.1 0.2 0.3 0.4 Pe l l e t D t e. ( tn. )

Figure 14 9 i

Comoarison Between CE and D?-1014 Calcu' ated Reflected and l

Ontimally Moderatec Cr< tical Mass versus 1 [510. Pellet Diame"er l

License No. SNM-33 Revision 1 Date: 9/28/98 l

Docket No. 70-36 Page: 14-61

i o

l v_

l e.

1 1

l j

1 N:

\\

\\

e.

^

g

.....Op_1014 I

c

  • * * * + CE j

s

.....UKAEA e_

ve.

I

\\

g 1

j ogb

\\

C s

s e:

N s

s e

s s

N

% s~

~

T iiieiiiiiieieiiiiiii.

iisiiii..

iis i.

1 2

3 4

5 w /o U-235 1

Figure 14-10 Corcarison of M' nimum Critical Reflected Heteroceneous Slab "hicknesses versus Enrichment l

t 4

License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-62 l

.~.

o y

e_

b.

= = = = = DP-1014 cxi u

E O @D.

L N

(si O

a:

c) n s

g 1

2 3

4 5

w/o U-235 Figure 14-11 Minimum Critical Reflected Surface Density versus Enrichment for I!1.1.tISB.neous UO,_llth I

i

' License No. SNM-33 Revision 1 Date: 9/28/98

. Docket No. 70-36 Page: 14-63 l'

I

s-Q I

l

\\

g~

m

\\

.....DP-1014

\\

....

\\

=

UKAEA a

v

. D.

Oe.

a O

M N

U-s N

N s

)

s

~

s i

b I I 5 I 55 8 3 1 lt 5 3 I B I I i3 lI B 5 3 3 3 5 5 I l5 I I 3 5 I I 8 8 l3 3 III 1

2 3

4 5

w/o U-235 Figure 14-12 Minimum Critical Reflected Cylinder Diameter versus Enrichment for Heteroceneous UO,-iiater Mixture i

I i

License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-64

o A

n-

\\

\\

  • ~

\\

l

= = = = = DP-1014

  • * * *

? e u UKAEA j

^s

-._) e -

m o

y e-i i

M-1 2

3 4

5 w /o U-235 Figure 14-13 Minimum Critical Reflected Scherical Volume versus Enrichment for Heteroceneous UO,-Water Mixture l-l y

License No. SNM-33 Revision 1 Date: 9/28/98 l

Docket No. 70-36 Page: 14-65 l

l

= -..

t G

= = = = = DP-1014

  • * * *
  • CE cslOJ c)100-y 1

2 3

4 5

w/o U-235 Figure 14-14 Minimum Critical Reflected Scherical Mass versus Enrichment' for Heteroaeneous 00,-Water Mixture i

1.

License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-66 l~

0.32 tn, SC Si ab T( cm)

O

... o o 0. 32 tn, SC Cy i. R( e m)

T 4A44* 0. 40 tn, SC Si ob T(em) 3 J

0. 40 tn. SC Cy l. RC em)

J C

0)b-O

E c_

o to.

3"-

a m.

A:

A e

0 1

2 3

4 H20/UO2 Figure 14-15 Minimum Subcritical Reflected Slab Thickness and Cylinder Radius versus Water-to-Oxide Ratio for Zircalov Clad. U1510, Pellet Columns in Water i

I License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-67

0.95 Masa Units s

I 41 Kg UO @ 3 w/o 2

11.75" Diameter 10.5' Diameter 0.90 KENO v

I Keff

+

17 Kg UO @ 5 w/o

+

9.5" Diameter 2

Was 11.75" Diameter 0.85 I

0.80 i

O.3 0.5 0.7 0.9 1.1 1.3 1.5 KgU/L Figure 14-16 j

KENO Keff including Uncertainty and Bias, versus Kilograme Uranium Per Uter for Mass Umited Unit Containers l

l 1

]

j l

License No. SNM-33 Revision 1 Date: 9/28/98 1

Docket No. 70-36 Page: 14-68 j

I

cviinder Units Volume Units 10'lD x 48"

@ 1.8 KgU/L 1.00 10"lD X 48' KENO

@ 1.8 KgUA.

Keff 9.34' ID

+

x 48" Uncertainty

@ 1.8 KgU/L

+

Bias O 96 16.5 L

@ 1.8 KgU/L 9.34' ID x 48"h 22 L r

0.90 0.87 02 02 OA 1s 12 g.0 Gjt 02 o.g 1.g tg gy 4

ts/tc KgU/L ts/tc KgU/L l

Figure 14-17 KENO Keff including Uncertainty and Bias versus ts/tc and KgU/L for Cylinder Diameter and Volume Umited Unit Containers i

i l

i l

License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-69

)

~.

c Water-to-UO, Volume Ratio -

1.50 -

1.320 u.

0.988 g

E f 1.40 2

o,740 1.30 a

e a

a 0

0.1 0.2 0.3 0.4 0.5 0.6 Pellet Diameter (inches)

Figure 14-18 Infinite Multiplication Factor versus Pellet Diameter for Several Water-to-UO, Volume Ratios License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-70

o 4

I i

V

  1. V H,0 UO, 2.0 l

1.50

- 1.5 l

l 1'

Koo l

1.45

~.

1.42 i

i i

10.25 10.50 10.75 11.00 Pellet Diameter (inches)

Figure 1419 Koo versus 0.400 Inch Diameter UO, Pellet Density at Various H,0-to-UO, Volume Ratios l

License No. SNM-33 Revision 1 Date: 9/28/90 Docket No. 70-36 Page: 14 71

=

A1%

Al%

5 g

g g

i

\\

\\

\\

Minimum Critical Volume g

g 4

N N

g g (CylinderDiameter, gSlab Thickness) s N

N g

'o

\\

\\

\\

s N

N \\

N E

3 g

N \\

~

s N N s

s N

s N

  • s N

Minimum Critical Mass s

ss s

5 2

's N s' s N

s s 's N

s s

s N.

N 1

Micronized Powder Pre-Micronized Powder e

0 i

i 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 UO, Bulk Density (gr/cc)

Figure 14-20 Loci of Minima in Reflected Minimum Critical Mass and Geometric Parameters with Enrichment and Bulk Density License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-72

mi mm E

O v

F-I

~

  • * * *
  • 0. 05 in. Pe l l e t

_O

.... 0.10 (n. Pe t l e t c m-

= = = = = 0. 20 in. Pe l l e t

  • * * *
  • 0. 40 in. Pe l i e t M

s

' n:

0,

-Q J

M i iiss' i

s s

i;isi' 1

10 Weter to Ox(de Re t to Figure 14-21 Reflected Suberitical (Safe! Slab Thickness versus Water-to Oxide Ratio for Unclad Uf 5)D, Pellets of Various Outer Diameters t

l l

l i

License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-73

o

~ o s%

i i

i i

N

\\ v s w.o

/

l i

1 o.7

/a~s i

l i

r 4

i I

o.s i

=

s" s

.o i

I I

I i

o.s o

0.2 0.4 o.s o.s 3.o Water Deneity Figure 14-22 kft versus Water Density and Planar Seoaration in 4 Inch Thick Infinite Slab Array of Pellet Trays License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-74

~.

..... = _.. -

-. _. ~,.. _

4 o

1.012 1.011 -

t 1.01 -

1.000 -

1.000 -

1,007 -

)

1,008 -

1.006 -

1.004 -

3 1.003 -

1.002 -

1.001 -

1-0.999 -

0.906 -

0.997 -

0.906 -

0.905 i

i i

i i

0 1

2 3

4 5

H20UO2 m

B&W

+

YM4(

e WIN WAPO X

  1. 4.

Figure 14 23

(,, versus Hgf$. 23 Exoeriments

,j f

.I-I License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-75

4-1.012

- 1.011 -

x 1.01 -

a e

1.000 -

x e

1.008 -

a 1.007 -

6 x

o 1.008 -

X 1.006 -

1.004 -

3 2

1.003 -

1.002 -

1.001 -

+

1-0.000 -

0.998 -

0.907 -

0.906 -

j 0.995 i

0.28 0.3 0.32 0.34 0.38 0.38 0.4 0.42 0.44 PELLET DtAMETER (IN) e B&W

+

YAMC o

WIN 4

WAPO x

APL Figure 14 24

(,,versusPellet0.D.

License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-76

-ss e

e l

1 i

1.012 x

1.011 -

x 6

1.01 -

3 1.000 -

x e

1.008 - a 1.007 -

og a

J 1.006 -

1.006 -

1.004 -

3 1.003 -

4 1.002 -

I.001 -

+

i 1-0.999 -

0.908 -

0.907 -

0.990 -

+

0.as i

2.4 2.8 3.2 3.8 4.0 4.4 4.8 5.2 5.6 W C 4 235 e

B&W

+

  • eM WW a

WApo x

ANL.

Figure 14 25 Keff versus Enrichment License No. SNM-33 Revision 1 Date: 9/28/98 Docket No 70-36 Page: 14-77

m.

4+

W I

1 i

I l

l 1

M" Heti erwt view f

>M s t:n.,y ;

f..

. tu: ::.

!![dllij.j :25: E:I:I!!N:D 9

m

!!!!iflI; : :25:

d ""**

2555 5ll:Ii

.s..,_

. !.g li in. /

l N_ :_:__

l am...uim a.

r

,,,,,i

=.n -:-:s l

+: - _ _-

m a nunu il!, ! nh

~,~-

.n

.....3

'i UNj' I

[-[-[ '!!!

unh':i E

Si i

H;i a

li.

d!! :mu u:

% so.

l

?it

.mi.-

811 IH$lii;1!!

t lg..:ifi i

i...

!!!!!!!!iEij "j

[

1.

> m, w.-

w.=

m a

>m

. m.

rs

_ _-5:E w

-555:i 25

  • 55553

' s

-h-8^4

_-g(

Lan== yed (sesentes mean Vl @

l

-1

-:::::::54

....cmmcm a

YMFM n.a mi.m een N__-

w,i. -

l l

l Figure 14-26 Excerimental Setuo for Exoeriments l

of Reference 29 i

j License No. SNM-33 Revision 1 Date: 9/28/98 l

Docket No. 70-36 Page: 14-78 i

l i

l 4

1 l

l l

I 1

Se c o n d Or d e r Po l y.n om te l Ftt of K-eff v.

Ave. En e r g y Group of Neu tron e Cousing Fleston.

1 1

e.020 1

s 4 1.010

-N O

s-O

\\

N e

N 1.000 p

g i

M O.990 0.980 14.00 14.40 14.80 15.20 15.60 Average Ne u tr o n En e r g y Group Figure 14-27 Keff versus Averaae Eneruy Group of Neutrons Causina Fission License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 14-79

F

. o.

Figure 15.2-1 Flow Diagram UFe to UO Conversion Process 2

  1. h[Y gh'

/

L'

%g OQrh d

a gkr

<3sy-19 V gyy'*

/ $'ff f

%[$s

,h a

Qf t

y N

S'-

D.yj h,-

,'LIN w,

x hc'gh'$631, 4j[t

/

?x{

l l

License No. SNM-33 Revision 1 Date: 9/28/98 Docket No. 70-36 Page: 15-20 l