Forwards GE MDE-49-0386, Ja Fitzpatrick Nuclear Power Plant Reactor Pressure Vessel Surveillance Matls Testing & Fracture Toughness Analysis
ML20155G431
Person / Time
Site: FitzPatrick 
Issue date: 04/30/1986
From: Brons J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: Muller D
Office of Nuclear Reactor Regulation
Shared Package
ML20155G436 List:
References
JPN-86-22, NUDOCS 8605060127
Download: ML20155G431 (2)


Text

.

123 Ma n Street White Plaens, New Wrk 10601 c

914 681.6240

  1. > NewYorkPbwer

"" t"";";m,

& Authority

" ->,oe April 30, 1986 JPN-86-22 Director of Nuclear Reactor Regulation U.

S. Nuclear Regulatory Commission Washington, DC 20555 Attention:

Mr. Daniel R. Muller. Director BWR Project Directorate No. 2 Division of BWR Licensing

Subject:

James A.

FitzPatrick Nuclear Power Plant Docket No. 50-333 Reactor Pressure Vessel Surveillance Materials Program Summary Report and Implementation Schedule

References:

1.

Code of Federal Regulations. Title 10, Part 50, Appendix H " Reactor Vessel Material Surveillance Program Requirements", 48FR24008, May 31, 1983.

2.

Code of Federal Regulations, Title 10, Part 50, Appendix G " Fracture Toughness Requirements" 48FR24008, May 31, 1983.

Dear Mr. Muller:

Reference 1 requires that the Authority have a program to monitor the fracture toughness properties of ferritic materials in the beltline region of the reactor vessel.

Under the program, data are obtained from tests of exposed material samples which are withdrawn periodically from the reactor vessel.

Reference 1 also requires that the report of the result of these tests be submitted to the NRC within one year of withdrawal of a reactor vessel sample.

A report on the FitzPatrick Reactor Vessel Surveillance Materials Testing and Fracture Toughness Analysis is attached.

Reference 2 requires that reactor vessel beltline materials maintain an End-of-Life (EOL) Charpy upper-shelf energy of no less than 50 ft-lb.

The predicted adjusted reference temperature must not exceed 2000F.

A reactor vessel material sample was removed during the Reload 6/ Cycle 7 outage.

The sample was analyzed, and the EOL adjusted reference temperature was determined to be 1040F.

The EOL values of upper shelf energy for plate and weld material were determined to be 58 lb-ft transverse and 72 ft-lb, respectively.

Therefore, the requirements of Reference 2 are satisfied.

Operating limit curves O

QC '

B605060127 860430

\\

\\

PDR ADOCK 05000333 I

P pop

a have been established for three reactor conditions: hydrostatic testing, non-nuclear heatup and cooldown, and core critical operation.

The curves are valid for up to 16 effective full power years of operation.

T.le FitzPatrick Technical Specifications will be revised to reflect the new pressure-temperature conditions.

The Authority expects to submit revised Technical Specifications in November 1986.

Current Technical Specifications are still within requirements tid can be used until that time.

Should y,u or your staff have any further questions regarding this matter, hlease contact Mr.

J.

A. Gray, Jr. of my staff.

V.y truly yours, i

l

.o.

o h n ' C '.

rons E enior Vice President uclear Generation cc:

Office of the Resident Inspecto U.

S. Nuclear Regulatory Commiss'on P.

O.

Box 136

Lycoming, N.Y.

13093 r

-.n

.., -,.