f APR 141996 Docket No. 50-285 MEMORANDUM FOR:

Ashok C. Thadani, Director PWR Project Directorate #8 Division of PWR Licensing-B FROM:

Ed G. Tourigny, Project Manager PWR Project Directorate #8

-Division of PWR Licensing-B

SUBJECT:

FORTHCOMING MEETING WITH OMAHA PUBLIC POWER DISTRICT (0 PPD), LICENSEE FOR FORT CALHOUN STATION, UNIT N0. 1 TIME AND DATE:

Tuesday, April 29, 1986, 2:00 pm - 4:30 pm Wednesday, April 30, 1986, 8:00 am - 4:00 pm Thursday, May 1, 1986, 8:00 am - 12:00 pm LOCATION:

Fort Calhoun Station Conference Room Washington County, Nebraska PURPOSE:

To obtain current plant specific data on the Fort Calhoun Station control room HVAC system.

The data will be used to expand the NRC's date base on control room operations and systems.

Temperature and air flow measurements will be made with the system in normal and emergency modes of operation.

A tentative detailed agenda is attached.

REQUESTED PARTICIPANTS:

NRC OPPD EFTourigny Jim Fisicano, et al.

Don Sells Jack Hayes Region IV Representative NRR Contractor Personnel (ANL)

NdnB Cfgnett by:

Ed G.Tourigny, Project Manager PWR Project Directorate #8 Division of PWR Licensing-B

Enclosures:

Tentative Agenda cc: w/ enclosures See next page-l 8604210383 860414 PDR ADOCK 05000295 f

l P

PDR

7-b':

Mr. R. L. Andrews Fort Calhoun Station

  • l Omaha Public Power District Unit No. I cc:

Harry H. Voigt, Esq.

LeBeeuf, Lamb, Leiby & MacRae 1333 New Hampshire Avenue, NW Washington, D.C.

20036 Mr. Jack Jensen, Chairman Washington County Board of Supervisors Blair, Nebraska 68008 Metropolitan Planning Agency ATTN: Dagnia Prieditis 7000 West Center Road Omaha, Nebraska 68107 Mr. Phillip Harrell, Resident Inspector U.S. Nuclear Regulatory Commission

~

P. O. Box 309 Fort Calhoun, Nebraska 68023 Mr. Charles B. Brinkman, Manager Washington Nuclear Operatins C-E Power Systems 7910 Woodmont Avenue Bethesda, Maryland 20814 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Office of Executive Director for Operations 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Mr. R. L. Andrews Division Manager - Nuclear Production Omaha Public Power District 1623 Hsrney Street Omaha, Nebraska 68102 t

i I

i L _.

1 2.

rp AGENDA FORT CALHOUN NUCLEAR STATION CONTRD'. ROOM HABITABILITY DISCUSSIONS l

Tuesday Anril 29. 1986 1400-1430 SECURITY DADGING 1430-1500 MEET WITH MC RESIDENT INSPECTOR AND REGION IV PERSONNEL 1500-1530 MEET WIN PLANT MANAGEMENT TO EXPLAIN THE PURPOSE F' THE VISIT 1530-1630 WALK g TM CR HVAC SYSTEM WDNESDAY Anril 30. 1986 0900-1000 DISCUSSION OF CR HVAC SYSTEM WITH PLANT PEREONNEL 1000-1200 TAKE PHOTOGRAPHS OF EQUIPMENT AND MAKE TEMPERATURE AND AIR FLOW MEASUREMENTS WITH THE SYSTEM IN THE NORMAL NODE OF OPERATION 1200-1300 LUNCH 1300-1430 CONTINUE SYSTEM DISCUSSION WITH PLANT PERSONNEL 1430-1600 MAKE TEMPERATURE AND AIR FLOW MEASUREMENTS WITH THE SYSTEM IN THE EMERGENCY MODE OF OPERATION Thuradav May 1.198&

0000-1030 CONTINUE SYSTEMS DISCUSSION WITH PLANT PERSONNEL TAKE ADDITION MEASUREMENTS AND PHOTOGRAPHS AB NEEDED 1130-1100 MEET WITH MC RESIDENT INSPECTOR AND REGION V PERSONNEL 1100-1200 CLOSE DUT MEETING WITH PLANT MANAGEMENT M The discussions on the second and third days of the vist may take less time than scheduled.

The agenda will be adjusted accordingly.

' t;;

~Meetina' Notices'

- #5 DI[bY

. Local PDR-PD#8 Reading

.0 RAS H. Denton A. _' Thadani ~

OELD-

'E. Jordan B. Grimes i

E.'Tourigny D.. Sells J. Hayes Region IV Representative i

NRR Contractor Personnel (ANL)

ACRS(10)

OPA' M. Schaaf Resident Inspector Region IV. Administrator cc:

Licensee Service List bY PD#8:

PD#8:

'ETour g :jch-AThadani