ML20155C334
| ML20155C334 | |
| Person / Time | |
|---|---|
| Issue date: | 10/23/1998 |
| From: | Hauber R NRC OFFICE OF INTERNATIONAL PROGRAMS (OIP) |
| To: | Delabarre R STATE, DEPT. OF |
| References | |
| NUDOCS 9811020201 | |
| Download: ML20155C334 (1) | |
Text
-
c#*
- h n
UNITED STATES l
f j
NUCLEAR REGULATORY COMMISSION WASHINGTON. D.C..M2664001 October 23, 1998 Mr. Robin DeLaBarre Office of Nuclear Energy Affairs Bureau of Political Military Affairs U.S. Department of State Washington, DC 20520
Dear Mr. DeLaBarre:
Enclosed is an application for an export license (XCOM1119), recently received by the Nuclear Regulatory Commission, for the export of refueling machine components for ultimate use in the Qinshan Nuclear Power Reactors in China.
Before taking action on this request, we would appreciate your views, in accordance with established procedures and from the overall perspective of the Executive Branch, as to whether the requested export meets the applicable criteria in the Atomic Energy Act of 1954, as amended.
Sincerely, gfw~'h Ronald D. Hauber, Director Division of Nonproliferation, Exports and Multilateral Relations Office of International Programs
Enclosure:
Appl. dtd. 10/15/98
( XCOM1119 - China)
)
cc w/ encl: T. Lee, DOE C. Riendieu, DOE J. Chuchia, DOC M. Johnson, DOD M. Rosenthal, ACDA AECB j
h 10 g 981023 XCOM-1119 PDR l
'h(
f'
_ _ ~ ~. - _. _
l NRc FORM 7 U.S. NUCLEAR REGULATORY CoMM&SSloN APeggyLg gi onag C0 allMMEl (3 94) 10 CF4 410 D881: 33107 (int 4Aftt 83JOI Pit it:PDSE 70 C0ld%T R' Tit MS Mf0stlAfice g0kII:TIG4 Rf0Vitt 17 APPLICATION FOR LICENSE TO EXPORT
""" * ""'"' "* " ".: u"r u'*ni,se ' "amun ceue'n ma"a,'e etwTwi no eouci con:wina s
NUCLEAR MATERIAL AND EQUIPMENT u0aiisman to M we=Ta ao ni:30s ummi nacc e rn e : Nutuu R(GULA10 7 C0hahstfG. RADeitT34. DC 205600ct. 440 TO M APttwat BCDUCTIGt I$ee instructions on Aoverse)
PtMC10%402 h. 0f ftl Of lLAA AGDOif ARC IgDo(1, R ASMN7tWu.DC 20403 1[ APPLICANT'$ e CAR OF A iCATsON
- s. APPLICANT & REFERENC
- e. COCERT WM
- t. M NMR _
g ggg
//d d 5 6 p 7 k'co M '///7 10-1s o8 nA2s60 U"
3 A*PLICANT S N AME AND ADDRESS M
Ag6,
- 4. SUPPLllR*$ NAAM AND ADDRE64 Valcor Enrineering Corporation
'C'"**'*"'aa'*'*"d***'*'"*'"'8 J. STRt T ADDRESS t/esafety 3 stet 4 NAME 9 T.n'.tverwe Ma a
- c. CITY a STATE. 2tP Coot
- t. STRit? ADORESS Sprinfield NJ 07081
- t. TILtPwoNa NUueeR so c.e.. SumA.,. s,r.n ni
.. CrTY
- e. STATE e 2IP CODE l
(o71) h67-8bno voot l
- 6. FIRST SMIPMENT
- 7. APPLIC ANT S CONTRACTUAL
- 8. PROPOSED LICENM
- 0. V S. DEPARTMENT OF ENERQY SCHE DULED SCMEDutt0 DELfVERY DATE EXPIAATION DAtt CONTRACT N0. Ist Anewn) 11.20-98 11-20-98 11-20-98 12-31-2003 l
io. UtnuArt romo04 Coa.SiONtt less
,i. UtTuAT: END un just co0E une4,oe punt er fecw nom.1 Third 0inshan Nuclear Power Company Qinshan Nuclear Power Plant t
. STRitt ADDRESS rr. care s,,,,
Refueling Machine Components-Machine
)
Haiyan requir.sd for on-line refueling process I
- c. CITY
- 4. COUNTRY Zhenilane China 1'* Daft 280V'At0 Approx. 6 -01 11 INTERMEDIAf t FOREIGN CONSiONEE mit
- 13. INTERMEDIATt END UG4 lU84000E
.. NAME AteM e Nvr-v ne car nan Assemble and test refueling machine;
.. STRe:T ADDatSS ~
T.+ a.
disassemble and ship to site 2251 Speakman Drive ssissaura. Ontario ed Lsr ino ise. DAT AtouiRfD Ipprox. 6-99
- 14. INTERMLOtAT4 7 ORE #0N CON 680NLt pas
- 16. INTERMEDIAit END USE p04 CODE a NAMI
- e. STRiti ADDRESS s/ scary 8, vel
- c. CITY d COUNTRY 16e. Daft REQUIRt0 10.COM
- 17. DESCRIPTION
- 13. M AX. ELIMENT 10. MAX. 20. MAX. 680TOPt 21.
- nce,#. she er and phskal fann of nuclear awrenet. she WoApr were of C004 W110HT WT.%
Wel0HT UNtf nuelser enement end earnpenent.l Differential Fypass & Excess Flow Check Valve s QTY,
193000007 V520-20-5 ASE III Class 1
'S J 193000008 v520-50-h 3/h" ASME III Class 3 13:
193000009 V520-50-6 3/h" ASE III Class 3 8-193000010 V520-50-5 3/h" ASME III Class 3
$300 Total Contract Value: b ' loo,000 USD.
l h
on b
- 22. COUNTRY OF ORadiN -
l
- 23. COUK TRY OF OR10lh - 84M INRICHED OR PRODUCED l 1 24. COUNTALES WMsCM ATTACM l-SOURCt MAftRIAL WHER:
gAptogARos (ff krwwn;
- 28. ADDITION AL INFORMAf tCN ON CONSl0 Nits. IND USIS. AND PRODUCT DESCRIPTiCN fuse separate sheet # neceswyl p 33130 UU See attached sheet gf ;f f w.p bI m e. Tn..,pe...at..rirvi.. in.i is,..,
..i.,,.p.,.4i...v.,,,viY wsntw.io.Ce4..,r.v.,.iR.,viii.....asin i.aine.,m ii.,ni 4 g,s....i.
e
...i i. in. i>...# hi. n., ka s wf.
W_
GiV v-~
(
D.P Sh8Ve
- '"L'3usiness Unit Manager
- 27. AUTHORGED OFFICtAL wo9 M W
-