ML20155B953

From kanterella
Jump to navigation Jump to search
Advises That Enforcement Conference Re 10CFR50.49 Violation Noted in Insp Rept 50-333/86-04 Will Be Held within 30 Days. Deficiency Involves Use of Unqualified Torque & Limit Switches in Recirculation Sys Discharge Lines
ML20155B953
Person / Time
Site: FitzPatrick 
Issue date: 09/28/1988
From: Martin T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Radford Converse
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
References
EA-88-239, NUDOCS 8810070167
Download: ML20155B953 (2)


See also: IR 05000333/1986004

Text

M

.

.

.A

l

~.

SEP 2 81938

Docket No. 50-333

EA No.88-239

Power Authority of the State of New York

James A. FitzPatrick Nuclear Power Plant

ATTN: Mr. Radford J. Converse

Resident Manager

P. O. Box 41

Lycoming, New York 13093

Gentlemen:

Subject:

Enforcement Con'erence

On March 23, 1986, your staff identified a potential violation of 10CFR 50.49

which relates to Equipment Qualification requirements.

This item was documented

in NRC Inspection Report No. 50-333/86-04.

This deficiency involves the use of

unqualified torque switches and limit switches (item 86-04-02) in the recircu-

lation systems discharge and discharge by pass valves.

The NRC is considering the potential violation for appropriate enforcemint

action. We plan to discuss the potential violation with you at an enforcement

conference in the Region I office within 30 days of your receipt of this letter.

At the enforcement conference, you should be prepared to discuss (1) the number

of deficiencies and the number of systems and components affected in this case;

(2) the specific and underlying cause(s) of the potential violation; and, (3)

the actions taken or planned to correct the potential violation as well as to

ensure yourself that the FitzPatrick Facility is currently in overall compliance

with EQ requirements.

Furthermore, you should be prepared to discuss the

potential violation in light of the Modified Enforcement Policy for EQ Require-

ments which is described in the enclosure to Generic Letter 88-07,

i.e., was

the item identified by you and was it promptly reported to the NRC? What were

your best efforts to comply with the rule within the deadline; and if appropriate,

why you believe that you clearly should .not have known of the deficiencies

prior to the November 30, 1985 deadline for being in compliance with the rule?

We request that at the enforcement conference you provide a handout that

succinctly describes your position concerning these enforcement considerations.

OFFICIAL RECORD COPY

EC LTR FITZ - 0001.0.0

09/26/88

8910070167 G80928

\\ D

ADOCKO';,00g3

Da

-

r-

-

.

s

SEP 2 81933

.

Power Authority of the

2

State of New York

At your earitest convenience, please contact Mr. Jacque Durr, of my staff, at

(215) 337-5282 to finalize arrangements for the enforcement conference.

Your

cooperation in this matter is appreciated.

Sincerely,

Ort?!nal Sigded Dv7

Thru T. I'.artin

Thomas T. Martin

Director

'

Division of Reactor Safety

cc w/ enc 1:

J. Phillip Bayne, President

Mr. John C. Brons, Executive Vice President

A. Klausmann, Senior Vice President - Appraisal and Compliance Services

R. L. Patch, Quality Assurance Superintendent

George M. Wilverding, Manager Nuclear Safety Evaluation

Gerald C. Goldstein, Assistant General Counsel

R. E. Beedle, Vice President Nuclear Support

S. S. Zulla, Vice President Nuclear Engineering

R. Burns, Vice President Nuclear Operation

Dept. of Public Service, State of New York

,

State of New York, Department of Law

Licensing Project Manager, NRR

Public Document Room (POR)

Local Public Document Room (LPOR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

State of New York

bcc w/ enc 1:

Region I Docket Room (with concurrences)

Management Assistant, ORMA (w/o enc 1)

Section Chief, DRP

Robert J. Bores, DRSS

B. Clayton, E00

C)?

Q

RI:0RS

RI:0R'S

  • '}'

..

Paolino/ mb/rw

Anderson

Du U

9/11/88

9//f /88

6

0FFICIAL RECORD COPY

EC LTR FITZ - 0001.1.0

09/16/88

-