ML20155B759
| ML20155B759 | |
| Person / Time | |
|---|---|
| Issue date: | 06/03/1988 |
| From: | Berlinger C Office of Nuclear Reactor Regulation |
| To: | Rossi C Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 8806130326 | |
| Download: ML20155B759 (3) | |
Text
&s}ge MAY 2 51988 hb S
~
00RE H
{M E i
MEMORANDUM FOR:
Charles E. Rossi, Director Division of Operational Events Assessment Office of Nuclear Reactor Regulation
- k EM b
FROM:
Carl H. Berlinger, Chief Generic Comunications Branch e
Division of Operational Events Assessment Office of Nuclear Reactor Regulation h g ]tQiW6.Ch
SUBJECT:
DIVISION DIRECTOR MEETING TO DISCUSS THE INDUSTRY PROGRAM AND NRC STAFF EFFORTS ADDRESSING MOTO -OPERATED VALVE PERFORMANCE DATE & TIME:
Friday, June 17, 1988 9:00 a.m.
LOCATION:
One White Flint North Room 10-B-11 PURPOSE:
To (1) discuss the current status of the industry and staff efforts addressing motor-operated valve performance and (2) develop a coordinated overall program so that the staff efforts complement the industry program.
PARTICIPANTS:
NRR AEOD B. K. Grimes T. M. Novak C. E. Rossi J. E. Rosenthal J. W. Roe E. J. Brown L. Shao J. Richardson RES C. H. Berlinger IT~A. Arlotto E. W. Brach R. L. Baer A. T. Gody M. Vagins L. B. Marsh
- 0. O. Rothberg G. C. Cwalina G. H. Weidenhamer E. J. Sullivan, Jr.
R. J. Kiessel E. M. McKenna Original Signed By Carl ti. Berlinger e806130326 g p03 Carl H. Berlinger, Chief PDR ORG PDR Generic Comunications Branch i
l Division of Operational Events Assessment Office of Nuclear Reactor Regulation
Enclosure:
Feeting Agenda CONTACT:
Richard J. Kiessel, NRR (301) 492-1154 t,);
, i-l DISTRIBUTION:
See page 2 f l ' b ' ' r.
6 J}
t/
cI T
OGCB:00EA:NRR C/0GCB:DOEA:NRR s
RJKiessel CHBerlinger
...O' -
05g/88 05/,ts'/88 4U 1
\\
Y
fH37
.o Charles E. Rossi DISTRIBUTION w/ enclosure E rley, NRR JHSniezek, NRR FMiraglia, NRR TTMartin, NRR CERossi, NRR CHBerlinger, NRR RJKiessel, NRR EJButcher, NRR WDLanning, NRR SAVarga, NRR DCrutchfield, NRR LCShao, NRR JGPartlow, NRR FCongel, NRR JRoe, NRR AThadani, NRR BKGrimes, NRR JRichardson, NRR EWBrach, NRR ATGody, NRR LBMarsh, NRR GCCwalina, NRR EJSullivan, NRR EMMcKenna, NRR EJordan, AE00 TPNovak, AEOD JERosenthal, AE00 EJBrown, AEOD BBHayes, Of SConnelly 01A WCParler, OGC SJChilk, SECY PPPDAS VStello, EDO MClausen, OC J6Keppler, OSP JLieberman, OE WMcDonald, ARM WKerr,SBDU/CR PEBird, OP l
HLThompson, HMSS I
GAArlotto, RES RLBaer, RES MVagins, RES 00Rothberg, RES GHWeidenhamer, RES HWoods, RES Regional Adminstrators PDR Central Files DCS 00EA R/F OGCB R/F RKiessel R/F
MAY 2 51933 Enclosure 4
MEETING AGENDA 9:00 T, M. Novak - Introductory Remarks 9:15 R. J. Kiessel - Status of Bulletin 85-03, "Motor-0perated Valve Common Mode Failures During Plant Transients Due to Improper Switch Settings" 9:30
- 0. O. Rothberg - Status of Generic Issue II.E.6, "In-Situ Testing of Valves" 945 G. H. Weidenhammer - Status of Generic Issue 87, "Failure of HPCI Steam Line Without Isolation" 10:00 E. M. McKenna - Maintenance Programs 10:30 E. J. Sullivan, Jr.
. Inservice Testing Programs; 10 CFR 50.55a Rule Change; and EPRI Testing Task Group Efforts 11:00 E. J. Brown - NUMARC, INPO, and NMAC Efforts; ASME OM-8 Efforts 11:45 T. M. Novak - Program Coordination Discussion s
(
i l
l
?
_-