Ack Receipt of Operator Licensing Exam Rept 50-346/98-301 Documenting Results of SRO Exams Administered Wk of 980803 & Concurrent Operations Insp.Seven Exam Questions Were Required to Be Deleted or Answers Changed,Per Comments
ML20155A128
Person / Time
Site: Davis Besse 
Issue date: 10/21/1998
From: Jeffery Wood
CENTERIOR ENERGY
To: Caldwell J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
1-1175, 50-346-98-301, NUDOCS 9810280150
Download: ML20155A128 (2)


Text

-

nm=

Daws-Besse Nuclear Power Station g gg 5501 North State Route 2 m

Oak HarDor,Ohoo 43449-9760 John K. Wood 419-249-2300 McePresiderg Nuclear Fax 419-3218337 J

Docket Number 50-346 License Number NPF-3 Serial Number 1-1175 October 21, 1998 Mr. J. L. Caldwell Acting Regional Administrator, Region III United States Nuclear Regulatory Commission 801 Warrenville Road Lisle, Illinois 60532-4351

Subject:

Response to Operator Licensing Examination Report 50-346/98301(OL)

Dear Mr. Caldwell:

The Davis-Besse Nuclear Power Station has received Operator Licensing Examination Report 50-346/98301 (OL), Toledo Edison Log Number 1-4010. This report documented the results of the Senior Reactor Operator (SRO) examinations administered the week of August 3,1998, and the concurrent operations inspection. This SRO written examination was prepared and administered in accordance with the guidelines provided in NUREG-1021, Operator Licensing Examination Standards for Power Reactors, Interim Revision 8, dated January,1997.

After the examination was administered, seven examincian questions were required to be deleted or answers changed as a result of post written c.s nination comments. This exceeded the five percent criteria stated in Section ES-501 C.2.c of NUREG-1021. A Potential Cc ndition

' Adverse to Quality Report (PCAQR) was initiated on August 10,1998, to investigate the cause i

of this occurrence and determine corrective actions to improve future opeiator license written examinations.

i The root cause investigation is in progress at this time and is considering the exam preparation

![)

process. This SRO examination was the first prepared in accordance with the guidelines of NUREG-1021, Interim Revision 8. Preparation of this examination was potentially impacted by a change of personnel responsible for reviewing and approving the examination. As documented

- m." n A,

, yV c.

4b\\

9810280150 981021

/

PDR ADOCK 050003464 4

V PDR

... - -. - ~...

Docket Number 50-346 License Number NPF-3 Serial 1-1175 Page 2 -

)

in this examination report, a significant number of examination questions, approximately 50 percent, had to be changed after the initial review. Due to this large number of required changes, the examination validation process may have been impacted. This root cause investigation is continuing and will be completed by February 23,1999. The Nuclear Regulatory Commission will then be provided the root cause and corrective actions.

. Requalification examinations are currently being administered to licensed operators. Due to the differences in the examination development and review process for the requalification exam versus the SRO exam just completed, the type of deficiencies encountered in the initial SRO exam should not occur.

Should you have additional questions or require additional information, please contact Mr. James L. Freels, Manager - Regulatory Affairs, at (419) 321-8466.

Sincerely yours,

/

DLM/dlc cc: A. G. Hansen, NRC Project Manager

{. J. Campbell, DB-1 Senior Resident Inspector VUSNRC Document Control Desk Utility Radiological Safety Board 1

.. - -