ML20154S580

From kanterella
Jump to navigation Jump to search
Forwards Revised Flow Diagram as Result of Meeting with La Dept of Environ Quality at River Bend Station on 981005.Also Based on Conversation,Util Submitting Listed Changes to Permit Renewal Application
ML20154S580
Person / Time
Site: River Bend Entergy icon.png
Issue date: 10/16/1998
From: Stoma S
ENTERGY OPERATIONS, INC.
To: Ballard E
LOUISIANA, STATE OF
References
RBG-44683, NUDOCS 9810280024
Download: ML20154S580 (3)


Text

su - .- a ..--, - - a a . ,

4.

s**

M!!~ENTERGY l"na@l"" "" '"*-

PO Box 220 St Franc 1svme. LA 70775 October 16,1998 Ms. Elizabeth A. Ballard Environmental Quality Specialist Office of Water Resources Louisiana Department of Environmental Quality.

Post Office Box 82215 Baton Rouge, LA 70884-2215 l l

Subject:

River Bend Station NPDES Permit No. LA0042731 and LWDPS Permit WP0409 Renewal Application Addendum

Reference:

LWDPS Permit WPO409 and NPDES Permit LA0042731 Filc No: G 1.11.7 I RBG - 44683

Dear Ms. Ballard:

We have attached a revised flow diagram as a result of our meeting with you at River Bend Station on October 5,1998. Also based on our conversation, we are submitting the following changes to the permit renewal application:

1. Renumber the internal outfalls as follows:

- Internal Outfall 201 (Former 004)

I Internal Outfall 301 (Former 102) o Internal Outfall 101 (Former 002)

2. For the Outfall 101 (Former 002) description, Low Volume Treated Wastewater, change solid waste dewatering to filter press effluent and delete the standby cooling tower as a wastewater source.
3. In regard to the description for Intemal Outfall 201 (Former 004) and the flow diagram, low volume wastewater from the diesel generator building sump is only ,,

discharged during maintenance activities. O 9810280024 981016 PDR ADOCK 05000458:

P PDR '

October 16,1998 RBG- 44683 -

Page 2 of 3

4. Add Internal Outfall 207 for the intennittent discharge of vehicle wash wastewater. The outfall location is at Latitude 30' 45' 31", Longitude 91* 20' 5" prior to commingling with any other waters of Outfall 007.
5. Delete Outfall 003, Low Volume Wastewater, and combine into Outfall 006.
6. Delete Outfall 008, Hydrostatic Test and Flush Wastewater, and combine into Outfalls 006 and 007 as maintenance wastewaters.
7. Change the description of Outfall 006 to include low volume wastewaters and maintenance wastewaters since Outfalls 003 and 008 have been combined into Outfall 006.
8. Change location of Outfall 006 to Latitude 30* 45' 31", Longitude 91* 20' 5".
9. Change the description of Outfal! 007 to include maintenance wastewaters since Outfall 008 has been combined into Outfall 007.
10. Remove the oil & grease monitoring requirement from Outfall 001, Cooling Tower Blowdown. This requirement was self-imposed in an effort to identify equipment maintenance problems during the early stages of plant operations.

Based on equipment performance over the past years and the long-term average oil & grease result of 1.19 mg/1, we have concluded that this monitoring requirement no longer serves a useful purpose to River Bend Station. Therefore, removing the oil & gmse monitoring requirement at this outfall will have no impact on water quahi.,.

I1. Change the chronic freshwater whole effluent toxicity biomonitoring to acute freshwater whoe :ffluent biomonitoring at a frequency of semiannual.

12. In regard to the temperature discussion for Outfall 001, the proposed power uprate at River Bend Station is planned in the year 1999.

If you have questions or require additional information, please contact Mr. Keith Stoma i at (225) 381-4784.

Since[y, 7

61 M%

'. K. Stoma i

Sr. Lead Environmental Specialist .

SKS/sks Attachment

. . . . = . . .. . . . . . - . - . . - .. .. .- .

. ... - - ~ ~ - . ,,

October 16,1998  !'

, . RBG - 44683 Page 3 of 3 l

cc: Mr. R. N. Buckley i

l Mr. Gus M. VonBodungen )

U. S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011 U. S. Nuclear Regulatory Commission Document Control Desk, OPI-37 Washington, DC 20555 NRC Sr. Resident inspector Post Office Box 1050 St. Francisville, LA 70775 l

l l

~ . - - - < . - - - ,