Monthly Operating Rept for Dec 1985
ML20154S550
Person / Time
Site: Cook 
Issue date: 12/31/1985
From: Climer, Will Smith
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF RESOURCE MANAGEMENT (ORM)
References
NUDOCS 8604010317
Download: ML20154S550 (7)


Text

.

v N.R.C.

OPERATING DATA REPORT DOCKET NO.

50-316 DATE 1/3/86 COMPLETED BY CLIMER TELEPHONE 616-465-5901 OPCRATING STATUS 1.

Unit Name D.

C.

Cook Unit 2

=-

2.

Reporting Pericd DEC 65 notes t

3.

Licensed Thermal Power (MWt) 3411 :

4.

Name Plate Rating (Gross MWe) 1133 :

5.

Design Electrical Rating (Net MWe) 1100 :

6.-Maximum Dependable Capacity'(GROSS MWe) 1100 :

7.

Maximum Dependable Capacity (Net-MWe) 1060 -----------

8.

If Channes Occur in Capacity Ratings (Items no. 3 through 7) Since Last Report Give Reasons ___

-9.

Power Level To Which Restricted. If Any (Net MWe) ____

10. Reasons For Restrictions. If Any:______

=---


===

This Mo.

Yr. to Date Cumm.

11. Hours in Reporting Period 744.0 8760.0 70128.0
12. No. of Hrs. Reactor Was Critical 744.0 5948.8 49028.8
13. Reactor Reserve Shutdown Hours 0.0 0.0 0.0
14. Hours Generator on Line 744.0 5855.0 47853.6
15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
16. Gross Therm. Energy Gen. (MWH) 2019347 18192549 151270610
17.. Gross Elect. Energy Gen. (MWH) 651340 5901160 49686590
18. Net Elect. Energy Gen. (MWH) 625333 5683634 47901368
19. Unit Service Factor 100.0 66.8 70.7 20.- Unit Availability Factor 100.0 66.8-70.7
21. Unit Capacity Factor (MDC Net) 79.3 61.2 66.9
22. Unit Capacity Factor (DER Net) 76.4 59.0 65.4
23. Unit Forced Outage Rate 0.0 32.7 15.8
24. Shutdowns Scheduled over Next Six. Months (Type,Date,and Duration):

REFUELING OUTAGE SCHEDULED TO START 3/1/86. EXPECTED DURATION 90 DAYS

25. If Shut Down At End of Report Period, Estimated Date of Startup:

- - - - - - - - =

26. Units in Teet Status (Prior to Commercial Operation):

Forcast Achieved INITIAL CRITICALITY INITIAL ELCCTRICITY

-COMMERCIAL GPERATION B604010317 851231 fI PDR ADOCM 05000316 R

pop g

~

AVERAGE DAILY POWER LEVEL (MWe-Net)

DOCKET NO.

50-316 UNIT TWO DATE 1/3/86 CCMPLETED BY CLIMER TELEPHONE o16-465-5901 MONTH DEC-85 AVERAGE DAILY AVERAGE DAILY DAY POWER LEVEL DAY POWER LEVEL

~1 852 17 856 2

854 18 851 3

654 19 859 4

853 20 848 5

853 21 853 6

852 22 858 7

670 23 721 8

813 24 783 9

857 25 855 10 855 26 858 11 855 27 858 12 851 28 854 13 848 29 858 14 852 30 857 15 854 31 858 16 857 l/

e l.

IMM?KEl No. 50-316 IINIl' SillllllOWNS ANilPOWI14 HlillitrilONS D.C. Cook - Unit 2 IJNII' N AblE IIAIE l-7-86 December, 1985 Contra E1Ellsay B.A. Svensson IllFOH1 Alf) Nill 1El.I:rilONE 616/465-5901 PAGE 1 of 1 "t.

I.icensee g -s,,

h,

'f g "g

)@ji ranse a reusedive 3

Aunen so N..

liate g@

ij g

livens Qj gU Peevent Heciusence oE j ;y, g Hepius

  • sn U 6

g d

167 851207 F

0 B

4 N.A.

HH HTEXCH Reactor power was reduced to 52%

to remove the main feed pumps from service, one at a time, to check the main feed pump. turbine conden-sers for tube leaks. One leaking tube was plugged in the east main feed pump turbine condenser.

Re-actor power was returned to 80% on 851208.

168 851223 F

0 B

4 N.A.

HF HTEXCH Reactor power was reduced to 56%

to remove the main feed pumps from service, one at a time, to clean the feed pump turbine condenser water boxes. Reactor power was re-turned to 80% on 851224.

I I

2

.I 4

1:: IoiccJ Heason:

blesinnl:

limlabit G Instincti.wis S: Stlicifulcel A tiepiipinens I;ailmell.nplain) 1-klannal feu Psepaiasisus of Haia 11 hiaintenance oiTest 24tanual Saane.

lintiy Slieces foi 1 icensee r Refuell"5

.I Autnmatic E sam.

I! vent Rep:n s il I Hll'ile (NilHI G-In Hegulaeosy Hestsicsson

-l Oslics Ilinplain) 01fil) 17 Opesatos l'eaining a licenw l mamination 1 Ailministrative 5

G Op easinual tissus Ilixplain) 1%lulut I S.ime Sams.c j

19//7) ll Ollic: llixplaisil

Dockot No.:

50-316 Unit Name:

D.C. Cook Unit 2 Y

Completed By:

D. A.

Bruck Telephone:

(616) 465-5901 Date:

January 6, 1986 Page:

1 of 2 MONTHLY OPERATING ACTIVITIES - DECEMBER, 1985 HIGHLIGHTS:

The reporting period began with the reactor at 80.5% rated thermal power.

On 12-07-85, reactor power was reduced to 52% to remove the main feed pumps from service -for condenser tube leak checks.

Reactor power was returned to E0.5% on 12-08-85.

On.12-23-85, reactor power was reduced to 56% to remove the main feed pumps from service for condenser cleaning.

Reactor power was returned to 80.5% on 12-24-85.

Engineered Safety Features actuations occurred as follows:

12-05-85, Containment isolation due to high radiation alarm.

12-11-85, Containment isolation due to high radiation alarm.

The reporting period ended with the reactor at 81% of rated thermal power.

Gross electrical generation for the month of December was 651,340 MWH.

SUMMARY

12-05-85 At 2109, an Engineered Safety Features actuation, containment isolation, occurred due to a high alarm on containment radiation monitor VRS-2201.

12-07-85 At 0945, a reactor power decrease began to remove the East Main Feed Pump from service to check for condenser tube leaks.

Reactor power reached 52% at 1215.

12-08-85 At 0025, a reactor power increase began.

At 0439, the reactor power increase was stopped at 79%

for chemistry.

At, 0642, reactor power was increased to 80.5%.

Docket No.:

50-316 Unit Names D.C.-Cook Unit 2 Completed By:

D. A. Bruck Telephone:

(616)-465-5901 Date:

January 6, 1906 Page:

2 of 2 12-11 At 094 2, an Engineered Safety Features actuation, containment isolation, occurred due to a high alarm on containment radiation monitor VRS-2201.

12-23-85 At 1000, a reactor power'decre'ase began to remove the main feed pumo enr.Jensers from service for cleaaing.

Reactor power reached 56% at 1825, and the East Main

~

Feed Pump was removed from service.

At 2114, the East Main Feed Pump was returned to service.

At 2219 the West Feed Pump was removed from service.

12-24-85 At 0056, the West Main Feed Pump was returned to service.

At 0121, a reactor power increase was begun.

At 1000, the reactor power increase was stopped at 79%

for chemistry.

At 1105, reactor power reached 80.5%.

t 4

)

..e,

-.4

~

- *s DOCKET NO.

50 --316

/

UNIT NAME D. C. Cook - Unit No. 2

.DATE l-7 COMPLETED BY B. A. Svensson TELEPHONE (616) 465-5901~~ '

PAGE 1 of 1 MAJOR SAFETY-RELATED MAINTENANCE DECEMBER, 1985 C&I-l'

- VCR-10, glycol containmet.t isolation valve does not close when given a " closed" signal.

Found ASCO solenoid valve not working properly. Rebuilt ASCO valve and verified proper operation of-the valve.

a t

w 4

i a

a

I

/Q,,,JNDIANA & MICHIGAN ELECTRIC _ COMPANY Donald C. Cook Nuclear Plant P.O. Box 458, Brdgman. M.chgan 49106 January 7, 1986 f

Director, Office of Management Information and Program Control U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Gentlemen:

Pursuant to the requirements of Donald C. Cook Nuclear Plant Unit 2 Technical Specification o.9.1.6, the attached Monthly Operating Report for the Month of December, 1985 is submitted.

Sincerely, (A]l wY)

W. G. Smith, Jr.

Plant Manager i