ML20154R747

From kanterella
Jump to navigation Jump to search
Registry of Radioactive Sealed Sources & Devices,Safety Evaluation of Radiography Source Assembly for Model C-1-R. Certificate:NR-300-S-853-S
ML20154R747
Person / Time
Issue date: 10/21/1998
From: Michele Burgess, John Lubinski
NRC
To:
Shared Package
ML20154R751 List:
References
SSD, NUDOCS 9810270176
Download: ML20154R747 (3)


Text

. - - - - - _ - - - _ _ _ - _ . . _ _ _ _ _ _ _ - _ - _ _ _ _ _ _ _ . . _ - - _ _ - _ _ _ _ _ - _ _ _ . _ -

REGISTRY OF. RADIOACTIVE SEALED SOURCES AND' DEVICES SAFETY. EVALUATION OF SEALED SOURCE NO.: NR-300-S-853-S- DATE: OCT 21 1998 .PAGE'1 OF 3 m SEALED SOURCE TYPE: Radiography Source' Assembly MODEL: C-1-R MANUFACTURER / DISTRIBUTOR: Gamma Industries,'Inc'.

P.O.. Box 2543-Baton Rouge, LA 70821

'll ISOTOPE:  ; MAXIMUM. ACTIVITY: 1

' Iridium-192 1 LEAK TEST FREQUENCY: 6 Months '

s I

PRINCIPAL.USE: (A) Industrial. Radiography CUSTOM SOURCE: 'YES X NO 9910270176 PDR 981021 1 RC e SSD PDR

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE NO.: NR-300-S-853-S DATE: OCT 2 1 1998 pAGE 2 OF 3 SEALED SOURCE TYPE: Radiography Source

  • Assembly DESCRIPTION:

Ohe Model'C-1-R source assembly is designed for use in the i

Cumberland Research Model_120' Exposure Device. The third

~

character in the source model designation indicates the' type of connector. The "R" ' indicates the radionist'or "T" Bar connector.

a The source is singly'encapsul'ted in 304 or.316' stainless steel.

The weld may be performed by Using andend cap weld, or sideL circumferential weld method,~either of which are_ accomplished using a TIG (heliarc)'weldingDtechnique. ' Capsule wall thickness

'is maintained at 0.030":(0.76,mm) minimum.. The connector, ball Estop, and' source ~ capsule-are. crimped to_a 1/8" (3.18 mm) or 3/32" (2.38 mm). stainless steel cable. -Overall pigtail dimension tolerances'are held'to il/16" (11.59 mm).

~ PROTOTYPE TESTING:

- This~ source has a classification of.E32515 as described in ANSI publication NS.10-1968. The manufacturer states that prototype sources have met the. test criteria specified in the ANSI

-document'.

~

' QUALITY ASSURANCE AND CONTROL:

Each." pigtail"Tassembly is subjected to'a 100 lb. (45.36 kg) pull test priorito source insertion, and is subjected to a contamination wipe test after the material is sealed in the capsule. If-the wipe test indicates contamination, then a hot water bubble test is performed.

LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:

c

.. The source-shall be possessed and used by persons specifically licensed by'the NRC.or an Agreement State.

REGISTRY.OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION'OF SEALED SOURCE NO.: NR-300-S-853-S DATE: CCT py 7ggg PAGE 3 OF 3

, SEALED SOURCE TYPE: Radiography Source Assembly LIMITATIONS AND/OR OTHER' CONSIDERATIONS OF USE (Cont'd):

~

. Handling, storage,.use,. transfer, and disposal: To be determined;by the licensing authority.

. This registration sheet and the information.. contained within

'the' references shall not be. changed without the written i consent-of-the NRC.

SAFETY ANALYSIS-

SUMMARY

The-Model C-1-R source.is no longer manufactured or distributed "by Gamma-Industries, Inc. and_ Gamma Industries, Inc. is no longer in business. Therefore,tthe reg'istration certificate is being converted to'an inactive; registration certificate.

.=

The source was oricjinally = approved for licensing purposes by the

' Louisiana' Division of' Radiation Control. NRC attempted to obtain copies of all information submitted by th'e registrant in support of'the evaluation. .However, NRCccould not' locate'all-the information. Therefore, no' safety evaluation.of the source was

~ performed as part of the-conversion'of the certificate to inactive status.

J l

ISSUING AGENCY:

U.S. Nuclear-Regulatory Commission /

Date: 2 I l998 - Reviewer: ,

/sohnW. Lubinski Date: Concurrence:  %,,M/M-e

'Michele L. Burgess

. . - -